14
Technical Information
Service Manual
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
X-FAN function
:
Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is displayed and the indoor fan will
continue operation for a few minutes in order to dry the indoor unit even though you have turned off the unit. After energization,
X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
●
Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for a few
minutes. at low speed. In this period, Hold fan speed button for 2s to stop indoor fan directly.
●
Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
●
This button is used for setting Fan Speed in the sequence that goes from AUTO,
,
FAN
:
5
Auto
Medium speed
Low-Medium speed
Low speed
High speed
Medium-High speed
to
then back to Auto.
,
,
,
6
Press this button to set up &down swing angle, which circularly changes as below :
OFF
This remote controller is universal . If any command , or is sent out, the unit will carry
indicates the guide louver swings as:
Press this button to turn on I FEEL function. The unit automatically adjust temperature according to the sensed temperature.
Press this button again to cancel I FEEL function.
I FEEL:
SWING:
7
out the command as
P
ress this button to achieve the on and off of healthy and scavenging functions in operation status.Press this button for the
first time to start scavenging function; LCD displays“ ”. Press the button for the
second time to start healthy and
scavenging functions
simultaneously; LCD displays“ ” and “ ” . Press this button for the third time to quit healthy
and scavenging functions simultaneously. Press the button for the fourth time to start healthy function; LCD display “ ”
Press this button again to repeat the operation above.
NOTE: This function is applicable to partial of models.
/
8
SLEEP:
9
Press this button, can select Sleep 1 ( ), Sleep 2 ( ),Sleep 3 ( ) and cancel the Sleep, circulate between these,
after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour, the main unit setting temperature will increase 1
ƽ
ƽ
đ
,setting temperature increased 2
đ
, the unit will run at this setting temperature; In Heat mode: sleep status after run for one hour, the
temperature will decrease 1
đ
, 2 hours, setting temperature will decrease 2
đ
, then the unit will run at this setting temperature.
ƽ
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
Sleep 3- the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep
the time of remote control will display "1 hour ", the setting temperature "88" will
setting status, at this time,
(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press "Trubo "button for confirmation;
(3) At this time, 1 hour will be automatically increased at the timer postion on the remote control, (that are "2 hours " or "3 hours "
(4) Repeat the above step (2)
Њ
(3) operation, until 8 hours temperature setting finished, sleep curve setting finished, at this time,
the remote control will resume the original timer display;
curve and blink (The first entering will display
display the corresponding temperature of last setting sleep
according to the initial curve setting value of original factory);
or "8 hours "), the place of setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink;
temperature display will resume to original setting temperature.
ƽ
Sleep3- the sleep curve setting under SLEEP mode by DIY could be inquired: