background image

INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING 

REMOVE CHASSIS

 

6.  Remove the shipping screws from the top of the unit and both sides of the cabinet if installed (FIG 6 & 7). 

7.  Hold the cabinet while pulling on the base handle to carefully remove the unit. Do not pull or lift near the top of the 

unit (FIG 8). 

8.  Remove the internal packing material prior to installation (FIG. 9) 
 
 
 
 
 
 
 
 
 

 

 

 8 

FIG. 9 

FIG. 6 

FIG. 7 

FIG. 8 

Содержание Thermocore GM-WAC-25ESE-C

Страница 1: ...Models GM WAC 25ESE C Electronic Window Air Conditioner Operating Instructions...

Страница 2: ......

Страница 3: ...e read this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages out...

Страница 4: ...n conformance with the National Electrical Code Quincy Massachusetts 02269 ANSI NFPA 70 latest edition and all local codes and ordinances LCDI Power Cord and Plug This air conditioner is equipped with...

Страница 5: ...es 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retainer 2 Window Sash Seal Foam Seal for Bottom Rail Owner s Manual 4 5 SEAL BOTTOM RAIL TO UNIT SIDE RETAINER FRAME A...

Страница 6: ...RESENTATION OF THE MANUFACTURER THERMOCORP INC HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 5 Model GM WAC 25ESE C Power Supply Ph V Hz 1 230 208 6...

Страница 7: ...o tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees o...

Страница 8: ...emove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gentl...

Страница 9: ...m the top of the unit and both sides of the cabinet if installed FIG 6 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift near the top of the unit F...

Страница 10: ...over the screws Top Angle Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle r...

Страница 11: ...the cabinet as shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accord...

Страница 12: ...as specified below MAX WALL THICKNESS 8 1 4 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood sc...

Страница 13: ...should be flush with the dry wall NOTE If wall thickness is 8 12 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and o...

Страница 14: ...STRUCTION 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in pl...

Страница 15: ...t light will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 0 5 24 hours To set the Auto off Timer press the TIMER button on the unit or...

Страница 16: ...ioner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be...

Страница 17: ...nd buttons a the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit is in...

Страница 18: ...he Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take...

Страница 19: ...Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from trippin...

Страница 20: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 21: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 22: ...or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Thermocorp Inc maintains a centralized service network to provide parts and assist in res...

Страница 23: ......

Страница 24: ...66129908034...