Operating Procedures Illustration
2
)
Remove the axial flow fan
z
Remove the cover plate (Fig. 4) and put it aside.
z
Remove the screws fixing the axial flow fan.
z
Pull the axial flow fan upward to remove
it from the motor axis.
Fig. 4
3
)
Remove the motor
z
Remove the 4 nuts fixing the motor.
z
Pull the cover plate upward and remove the motor (Fig. 5)
图
5
Fig. 5
4
)
Remove the side plate
z
Loosen the tapping screws fixing the side plate.
z
Pull outward to remove the side plate (Fig. 6).
Screw
Tapping
screw