background image

 

IMPORTANT SAFEGUARDS

 

 

Important Safeguards. 

•Read all instructions. 
•Disconnect  the  power  plug  before  dismantling,  assembling  or  before 

cleaning. 

•Avoid touching mobile parts of the appliance. 
•Never insert fingers, pencils or any other objects though the guards whenever 

the power plug is connected, especially while running. 

•The  appliance  is  not  intended  for  use  by  young  children  or  infirm  persons 

unless  they  have  been  adequately  supervised  by  a  responsible  person  to 
ensure that they can use the unit safely. 

•Young children should be supervised to ensure that they do not play with the 

appliance. 

•Do not use the appliance for any other purpose than its intended use. 
•The appliance must not be used if the guards are not fastened according to 

instructions. 

•When the power cord is damaged, it must be replaced by the manufacturer or 

its service agent or a similarly qualified person in order to avoid a hazard. 

•Do not use your appliance with an extension cord unless it has been checked 

and tested by a qualified electrician or electrical supplier. 

•Return to Hagemeyer or authorised service agent. 

The air conditioning unit must always be stored and transported upright, 

otherwise  you  may  cause  irreparable  damage  to  the  compressor;  in 
case of doubt we suggest to wait for at least 24 hours before you start 
the air-conditioning unit. 

•Avoid restarting the air conditioning unit unless 4 minutes have passed since 

being turned off, or the compressor may get damaged. 

•Never use the mains plug as a switch to start and turn off the air conditioning 

unit. Use the provided ON/OFF switch located on the control panel. 

•Always place the portable air conditioner on a dry stable surface. 

 

 

 

Содержание KY-26

Страница 1: ...Y 32 KYD 32 KY 44 KYD 44 PORTABLE AIR CONDITIONER Thank you for selecting super quality air conditioner Please be sure to read this manual carefully before using it Any question please contact the pro...

Страница 2: ...1 IMPORTANT SAFEGUARDS 2 FEATURES AND PARTS LIST 4 PANEL CONTROL 5 REMOTE CONTROL 6 OPERATION METHODS 7 INSTALLATION 8 WATER DRAINGE METHODS 10 MAINTENANCE 11 TROUBLE SHOOTING 12 INSTALLATION ACCESSO...

Страница 3: ...g to instructions When the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Do not use your appliance with...

Страница 4: ...of the day Keep the filters clean Under normal conditions the filters should be cleaned approximately every 30 days Since the filters remove airborne particles more frequent cleaning maybe necessary d...

Страница 5: ...gy saving and environment protect Low noise and strong wind Unique economic function Auto swing makes wind blow from left to right automatically Three minute restart delay to protect compressor Parts...

Страница 6: ...ol heat dry or fan mode heat mode only in YPC H models Econ press this button to a set energy saving mode only in heat and cool mode This set temperature is 27 in cool mode and 23 in heat mode The fan...

Страница 7: ...Press this button to choose Fan mode Up Press Up or Down button to set temperature Down or adjust the time in Timer mode High Press this button to select high fan speed Med Press this button to select...

Страница 8: ...tically Cooling Heating and Dehumidifying operation 1 Cooling Heating operation Press Mode button or to choose Cool heat mode Press Up or Down button or to set a proper room temperature The range is 1...

Страница 9: ...is between 600cm to 1700cm or 1800cm adapters included We suggest using the minimum length of the air exhaust dust That can save energy for you This length has been designed especially according to th...

Страница 10: ...9 4 Mounting illustrations 1 mounting in the wall 2 correct bending 3 wrong bending...

Страница 11: ...evel or drained by hand When the alarm stops and after three minutes restart delay the unit will work normally You can drain the water out with a drain pipe It is included in the accessory But first y...

Страница 12: ...Rinse the filter and dry it in a shaded place 3 Push the air filter back into the original position End of season 1 Pull out the plug from the drain mouth and remove the water from the drain pan You c...

Страница 13: ...able fan speed Too noisy and vibration It is the inner liquid refrigerant flowing inside Is it inclined It is normal Place it in a flat place The unit starts and stops frequently Is the voltage normal...

Страница 14: ...ch from 7000BTU 8000BTU 9000BTU 14 36cm up to 59 150cm 12000BTU 14000BTU 15000BTU 15 38cm up to 59 150cm Window exhaust adapter flat mouth 1pc Adjustable window slider kit 2 set From 35 3 8 90cm up to...

Страница 15: ...1 Fuse Parameter Type FSD Voltage 250V Current 3 15A 2 Wiring Diagram Fig 16 Disposal Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment...