www.enviromaster.com
EnviroAir High Wall Ductless Split Systems
9
ENVIROAIR HIGH WALL DUCTLESS SPLIT SYSTEMS
INDOOR UNIT INSTALLATION
Install unit on mounting bracket
Feed the line set stubs/condensate hose/
wiring connections through a ø 3” hole in
the wall.
Position the evaporator so that the “key”
slots on the back of the unit slide onto the
tabs on top of the mounting bracket. Then
push the lower portion of the evaporator
against the bracket until it latches into the
mounting bracket.
Indoor unit is now installed, it should be
plumb, level and fl ush with the wall. In-
sure that the line set stubs are completely
18,000
Btuh shown
OUTDOOR UNIT INSTALLATION
Locate Outdoor unit
Select a location with proper ventilation,
minimizing recirculation possibility. Do not
install the outdoor unit in a location ex-
posed to high winds
(fi eld fabricated and
installed wind baffl e may be required)
.
Ensure location does not impede access
around unit and pose a disturbance to
neighboring areas.
Clearances for the Outdoor unit:
12” Minimum
12” Minimum
48” Minimum
12” Minimum
Service
Valves
Note: Consult factory if
minimum clearances can’t
be maintained.
Outdoor Unit
Rear
Condenser Fan
Front
Airfl ow
Install the outdoor unit on a condenser
service pad. If unit is a heat pump ex-
tend feet to raise 6” to allow for defrost
to drain away.
through the wall penetration, also check
that the wall is plumb. The unit must be
level and plumb for proper condensate
removal.