System diagram
System diagram for cooling only type
System diagram for cooling/heating type
Evaporator
Cross flow fan
Capillary
Filter
Condenser
Compressor
Gas-liquid separator
Axial flow fan
Evaporator
Cross flow fan
Heating
Cooling
One-way valve
Main capillary
Filter
Auxillary capillary
Axial flow fan
Condenser
Compressor
Gas-liquid separator
Electromagnetic
4-way valve
When the power is on, indoor and outdoor units will start to run. The compressor sucks low-pressure refrigerant gas from the evaporator of
indoor unit and then discharges high-temperature, high-pressure refrigerant gas into outdoor condenser. Then air exchanges the heat with outdoor air
and becomes refrigerant liquid. The liquid is throttled by the capillary and changes into low-temperature and low-pressure liquid and then flows
into indoor evaporator. Then liquid exchanges the heat with the required air and changes into low-temperature and low-pressure refrigerant gas.
The cycle introduced above goes on and on, and the demanded low temperature environment is maintained.
When the power is on, indoor and outdoor units will start to run. When the system operates in cool mode, the compressor sucks low-temperature, low-
pressure refrigerant gas from indoor evaporator and then discharges high-temperature, high-pressure refrigerant gas into outdoor heat exchanger. With
the help of axial flow fan, the gas transfers its latent heat into outdoor air and becomes high-pressure refrigerant liquid. The liquid is throttled by the
capillary and changes into low-temperature and low-pressure liquid and then flows into indoor heat exchanger. With the help of centrifugal fan, the
liquid evaporates into low-temperature refrigerant gas and indoor air is cooled down. The refrigerant gas is sucked into the compressor and the cycle
introduced above goes on and on, and the demanded low temperature environment is maintained.
When the system operates in heat mode, 4-way valve changes its way and the refrigerant flows into the reversible cycle as the cool mode. The
refrigerant discharges its latent heat in the indoor heat exchanger, and sucks heat from outdoor heat exchanger and forms the heat pump cycle.
This cycle goes on and on, and the demanded high temperature environment is maintained.
Bird Single-Split Type
Содержание KFR-32GW/NA21
Страница 1: ...1 Summary and features Models Remarks Bird Single Split Type...
Страница 2: ...Models Remarks...
Страница 3: ...Remarks Models Bird Single Split Type...
Страница 4: ...Models Remarks...
Страница 28: ...320 Handle Spanner Nut Bolt above above above above...
Страница 29: ...Bolt Nut Spanner Handle above above above above Bird Single Split Type...
Страница 30: ...Handle Bolt Nut Spanner above above above above...
Страница 32: ...6 6 6 6 6 Circuit diagram...
Страница 33: ...Bird Single Split Type...
Страница 34: ......
Страница 35: ...Bird Single Split Type...
Страница 36: ......
Страница 37: ...Bird Single Split Type...
Страница 38: ......
Страница 39: ...Bird Single Split Type...
Страница 40: ......
Страница 41: ...Bird Single Split Type...
Страница 42: ...These circuit diagrams are subject to change without notice Please refer to the ones stuck on the machines...
Страница 77: ...9 Explosive view and spare parts list Explosive view of indoor unit Bird Single Split Type...
Страница 96: ...T he explosive view of the small outdoor unit...
Страница 103: ...Disassembly of Components of Big Outdoor Unit Bird Single Split Type...
Страница 118: ...Disassembly of Components of Plastic Case Outdoor Unit...