12
Condensing Unit
Service Manual
CONTROL
9
X-FAN button
● Pressing X -FAN button in COOL or DRY mode, the icon "X-FAN" is displayed and the
indoor fan will continue operation for 10 minutes in order to dry the indoor unit even
though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is
not available in AUTO,FAN and HEAT mode.
10
TEMP button
●
After powered on, displaying presetting temperature is defaulted,(According to customer
requirements to display,if there are no requirements,the presetting temperature displaying
is defaulted, there is no signal display on the wireless remote controller). Press this
button, (display
), display the presetting temperature; (display
), display indoor
ambient temperature,
will not change current display status. If current display status
is indoor ambient temp. when received other wireless remote controller sginal, then will
display presetting temp., 5s later return to ambient temp. display.
● Other models haven't this function. But pressing this button, the main unit will click and
keep the original status.
11
TIMER button
● On the status of the unit on, press this button to set timer off. On the status of the unit off,
press this button to set timer on. Press this button once, words Hour on(off) will appear
and flicker. In which case, press +/- button to adjust time (press +/- button continuously
to change timing value quickly ), the setting time range is from 0.5 to 24 hr. ; press this
button once again to fix the time,then the wireless remote controller will send out the
signal immediately and hour on/off will stop flickering.If the time of that no press timer
button under flickering status is above 5s,the timer setting will quit. If the timer has been
set,press this button once again to quit it.
12
TURBO button
● Set turbo on or off(the characters of turbo will appear or disappear ) by pressing this
button under cooling or heating mode.Once energized, the unit will be defaulted to be
turbo off. This function can not be set under auto, dehumidify or fan mode, and characters
of turbo won't appear.
13
SLEEP button
● Press this button, enter into SLEEP state,when repressed, it will quit. The sleep function
will be canceled with the stop of the unit. There is no SLEEP function under AUTO and
FAN mode. is the icon for sleep function.
● At COOL, X-FAN mode: the SLEEP mode runs after 1hour, the setting temp. will be
increased by 1
o
C, 2 hour later, the setting temp. will be increased by 2
o
C and then will
run at this setting temperature.
● At HEAT mode: the SLEEP mode runs after 1 hour, the setting temp. will be decreased
by 1
o
C, 2 hours later the setting temp. will be decreased by 2
o
C, then it will run at setting
temperature.
14
LIGHT button
● Press this button to select LIGHT on or off in the displayer. When the LIGHT on is set,the
icon
will be displayed and the indicator light in the displayer will be on. When the
LIGHT off is set, the icon
will be not displayed and the indicator light in the displayer
will be off.
3.1.3 Introduction for special function
About X-FAN function
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to
avoid mould.
(1).
Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will
continue running for about 10 min. at low speed. In this period, press X-FAN button to stop indoor fan
directly.
(2).
Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will
Содержание HNTF24/A-D
Страница 1: ...Condensing Unit Service Manual T1 R410A 60Hz GC201408...
Страница 3: ...1 Condensing Unit Service Manual PRODUCT PRODUCT...
Страница 8: ...6 Condensing Unit Service Manual CONTROL CONTROL...
Страница 20: ...18 Condensing Unit Service Manual INSTALLATION...
Страница 32: ...30 Condensing Unit Service Manual MAINTENANCE...
Страница 40: ...38 Condensing Unit Service Manual 5 EXPLODED VIEWS AND PART LIST 1 Model HNTF24 A D HNTF36 A D Exploded Views...
Страница 45: ...JF00302341...