background image

28

Installation of indoor unit

Step eight: bind up pipe

1. Bind up the connection pipe, power 

    cord and drain hose with the band.

indoor unit

gas

pipe

indoor and

outdoor power cord

liquid pipe

drain hose

band

2. Reserve a certain length of drain 

    hose and power cord for installation 

    when binding them. When binding to

    a certain degree, separate the indoor

    power and then separate the drain 

    hose.

3. Bind them evenly.

4. The liquid pipe and gas pipe should 

    be bound separately at the end.

Note:

 The power cord and control wire 

   can't be crossed or winding.

 The drain hose should be bound 

   at the bottom.

drain hose band

connection pipe

indoor power cord

Step nine: hang the indoor unit

1. Put the bound pipes in the wall pipe and then make them pass through the wall 

    hole.

2. Hang the indoor unit on the wall-mounting frame.

3. Stuff the gap between pipes and wall hole with sealing gum.

4. Fix the wall pipe.

5. Check if the indoor unit is installed firmly and closed to the wall.

Note:

● Do not bend the drain hose too excessively in order to prevent blocking.

indoor

outdoor

wall pipe

sealing gum

upper hook

lower hook of

wall-mounting frame

Содержание GWH09QB-K3DNA1G/I

Страница 1: ...or choosing our product If you have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper operation please read and keep this manual carefully ...

Страница 2: ... K3DNB8G I GWH09QB K3DNA5G I GWH12QC K3DNA1G I GWH18QD K3DNA1G I GWH24QE K3DNA1G I GWH24QE K3DNB4G I GWH09QB K3DNC2G I GWH24QE K3DNB6G I GWH24QE K3DNA5G I GWH12QC K3DNA5G I GWH18QD K3DNA5G I GWH18QD K3DNB6G I GWH12QC K3DNB6G I GWH09QB K3DNB6G I ...

Страница 3: ...t of batteries in remote controller 13 Emergency operation 14 Maintenance Clean and Maintenance 14 Malfunction Malfunction analysis 17 Installation Notice Installation dimension diagram 21 Tools for installation 22 Selection of installation location 22 Requirements for electric connection 23 Installation Installation of indoor unit 24 Check after installation 29 Test and operation Test operation 2...

Страница 4: ...at if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION WARNING CAUTION DANGER NOTICE ...

Страница 5: ...ce Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric shock ...

Страница 6: ...damage 2 Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause obje...

Страница 7: ...efore using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please Air C...

Страница 8: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrigerant c...

Страница 9: ...talled in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 43 26 Maximum heating 27 24 18 The operating temperature range outdoor temperature for cooling is 15 43 Heating temperature rang...

Страница 10: ...erent from above graphics please refer to actual products Parts Name Indoor Unit remote control air inlet panel aux button horizontal louver air outlet NOTICE Actual product may be different from above graphics please refer to actual products ...

Страница 11: ...or display For some model For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display G W R Power LED color indicator Green status ON Red status OFF Mode LED color indicator White W Cool Mode Red R Heat Mode Green G Dry Mode O W R Power LED color indicator Green status ON Red status OFF Mode LED color indi...

Страница 12: ...LOCK button TIMER ON button SLEEP button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed ventilation operation Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Clock Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel 6 9 8 12 15 4 7 10 5 11 X FAN button MODE button bu...

Страница 13: ... Press this button to increase set temperature Holding it down above 2 seconds rapidly increases set temperature In AUTO mode set temperature is not adjustable MODE button 3 Each time you press this button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT as the following SWING button 4 Press this button to set up down swing angle which circularly changes as below After en...

Страница 14: ...n to initiate the auto ON timer To cancel the auto timer program simply press this button again After press of this button disappears and ON blinks 00 00 is displayed for ON time setting Within 5 seconds press or button to adjust the time value Every press of either button changes the time setting by 1 minute Holding down either button rapidly changes the time setting by 1 minute and then 10 minut...

Страница 15: ...high fan speed Caution This model hasn t outdoor ambient temperature display function While remote controller can operate and indoor unit displays set temperature It s defaulted to display set temperature when turning on the unit Only for the models with temperature indicator on indoor unit X FAN button 14 Press this button to turn on I FEEL function The unit automatically adjust temperature accor...

Страница 16: ...ress TEMP and CLOCK simultaneously in COOL mode to start energy saving function Nixie tube on the remote controller displays and a selected temperature of 8 46 if Fahrenheit is adopted Repeat the operation to quit the function Combination of TEMP and CLOCK buttons About 8 Heating Function Press TEMP and CLOCK simultaneously in HEAT mode to start 8 Heating Function WIFI Function Press MODE and TURB...

Страница 17: ...ow direction 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box NOTICE During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them or wireless telephone r...

Страница 18: ...off the air conditioner The operation in details are as below WARNING NOTICE Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommende...

Страница 19: ...use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly The filter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or ...

Страница 20: ... damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner please contact local dealer or consultant service center for the correct disposal method NOTICE Checking before use season NOTICE Checking after use season ...

Страница 21: ...room Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it aga...

Страница 22: ...oor temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperatu...

Страница 23: ...he noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature Air conditio ner operates abnormally suddenly Whether there s interference such as thunder wireless devices etc Discon...

Страница 24: ...rn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner operates under abnormal conditions it may cause Malfunction analysis Error Code When air conditioner status is abnormal temperature indicator on indoor unit wi...

Страница 25: ...21 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall ...

Страница 26: ... 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for installation Don t use unqualified power cord Basic requirement Indoor unit Installing the unit in the following places maycause malfunction If it is unav...

Страница 27: ...ed it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations 1 The air conditioner is the first class electric appliance It must be properly gr...

Страница 28: ...e Wall Space to the wall above 150mm Space to the wall above 150mm Φ70mm Rear piping hole 2 Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 12K 24K Left Wall Φ55mm Right Mark in the middle of it Level meter Rear piping hole Wall Space ...

Страница 29: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit union nut pipe joint pipe Indoor 5 10 outdoor Φ70 Φ55 Note Pay attention to dust prevention and take relevant safety ...

Страница 30: ...he indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw panel Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con Installation of indoor unit torque wrench open end wrench indoor pipe pipe union nut Hex nut diameter Tightening torque N m...

Страница 31: ... must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw with wire clip power connection wire cable cross hole 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and...

Страница 32: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with seal...

Страница 33: ... power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely It may cause insufficient cooling he...

Страница 34: ...al refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Cooling capacity Cooling capacity 5000Btu h 1465W 24000Btu h 7032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu h 10548W 12000Btu h 3516W 42000Btu h...

Страница 35: ...eter of connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ12 Φ16 Φ19 Φ22 2 Φ9 52 or Φ12 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe ...

Страница 36: ...and prevent the burrs from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F I...

Страница 37: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000291 ...