background image

Remote controller description

 

ON/OFF  :

MODE :

+

:

FAN :

1

2

4

3

5

Operation of Remote Controller

7

Press this button to turn on the unit

Press this button again to turn off the unit.

Each time you press this button,a mode is selected in a sequence that goes from AUTO,
COOL, DRY, FAN,and HEAT

*

, as the following:

AUTO

COOL

DRY

FAN

HEAT

*

*Note: Only for models with heating function.

After energization, AUTO mode is  defaulted. In AUTO mode, the set temperature will not

be displayed on the LCD, and the unit will  automatically select the suitable operation 

mode in accordance with the room temperature to make indoor room comfortable.

Press

 this button to decrease set temperature. Hold it down for above 2 seconds to 

rapidly decrease set temperature. In AUTO mode, set temperature is not adjustable. 

Press this button to increase set temperature. Hold it down for above 2 seconds to

rapidly increase set temperature. In AUTO mode, set temperature is not adjustable. 

This button is used for setting  fan speed in the sequence that goes from AUTO,

to

then back to Auto.

,

,

,

Auto

Low speed 

Medium speed

High speed

:

6

       

simple swing and static swing; 

blinks for 2 seconds.

In static swing condition, pressing

If the unit is turned off during swing operation,the louver will stop at present position.

button, the swing angle of up & down louver

 changes as below:  

Press       button to start or stop up & down swing function.The remote controller

Press + button and      button at the same time at unit OFF to switch between

defaults to simple swing condition. 

Содержание GWC36LB-D3DNXXE Series

Страница 1: ...Thank you for choosing Residential manual carefully before operation and retain it for future reference Air Conditioners please read this owner s MODEL GWH30LB D3DNXXE GWC36LB D3DNXXE GWH36LB D3DNXXE...

Страница 2: ...physical product may differ from the drawing in this manual for different display If there are some differences between them please refer to the physical product as the standard This appliance is not...

Страница 3: ...er supply when the air conditioner won t be used for an extended period of time Otherwise it will accumulate dust and it may cause overhe ating fire and other accidents Do not damage the power cord or...

Страница 4: ...ause malfunctions Keep combustible materials away from the units at least 1m It may cause fire or explosion It may cause falling of the unit and injury to the person Install the outdoor unit firmly en...

Страница 5: ...nds or objects into the air in let or outlet It may cause an accident Do not expose animals or plants directly to the air flow Do not expose yourself to cold air directly for a long time Do not use th...

Страница 6: ...lter Horizontal louver Wall pipe Binding tape Connection Pipe Drain hose Drain connecter Name of Parts Indoor unit Cool Dry Heat Set temp Power The icons displayed 4 Outdoor unit Air in Air out Air in...

Страница 7: ...HEAT Press it to increase temperature setting Press it to decrease temperature setting FA HEALTH SAVE N Press it to set up down swing angle Press it to turn on off the light TIMER X FAN page 8 page 8...

Страница 8: ...utton again to clear the display AUTO COOL DRY FAN or HEAT only for heat pump models will show 15 Left right swing icon 20 Up down swing icon After pressing TIMER button ON or OFF will blink This area...

Страница 9: ...emperature Hold it down for above 2 seconds to rapidly decrease set temperature In AUTO mode set temperature is not adjustable Press this button to increase set temperature Hold it down for above 2 se...

Страница 10: ...X FAN button in COOL or DRY mode the icon X FAN is displayed and the indoor fan will continue operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit After en...

Страница 11: ...n replacing the batteries do not use old or different batteries If the wireless remote controller will not be used for a long time please otherwise it may cause malfunction remove batteries to prevent...

Страница 12: ...mperature setting or fan speed can not be changed The manual switch can be operated as below Turn on the unit Press AUTO STOP button to enter AUTO mode The microcomputer will select the mode COOL HEAT...

Страница 13: ...components and circuit diagram on the front panel Do not to touch the fin of indoor unit during cleaning to avoid personal injury Care and Cleaning 11 Clean the air filter Take down the air filter Li...

Страница 14: ...ilter and Clear obstructions from the outdoor unit Check if the batteries of remote controller are replaced Check if the installation stand of the outdoor unit is damaged If damaged consult the techni...

Страница 15: ...unit Mist is emitted in COOL mode During cooling operation a thin mist may be seen emitted from the indoor unit due to high room temperature and humidity After a period of time the mist will disappea...

Страница 16: ...eck if there is magnetic or electrical interference near the unit that may affecting operation of the controller In this case cut off the power supply as the air conditioner and reinsert it Is the rem...

Страница 17: ...mitted during operation The air switch or protection switch often trips Power cord and power plug is overheating n o i t a r e p o p o t S and cut off the power supply Troubleshooting Phenomenon Troub...

Страница 18: ...ficiency The air conditioner may stop operation during auto defrosting operation During auto defrosting the fan motors of indoor unit and outdoor unit will stop During defrosting the indoor indicator...

Страница 19: ...rom outdoors is favorable for cooling heating Clean air filters once per two weeks Clogged air filters lead to inefficient operation and energy waste Tip for relative humidity Condensate water is like...

Страница 20: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI...