14
Technical Information
Service Manual
Connection pipe specification:
Liquid pipe:1/4"
Gas pipe: 1/2"
Indoor unit
Outdoor unit
COOLING
HEATING
4-Way valve
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Strainer
Electron
expansion
valve
Strainer
Accumlator
Compressor
Indoor unit
Outdoor unit
Accumlator
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Strainer
Compressor
Electron
expansion
valve
4. Refrigerant System Diagram
Cooling only models
Cooling and heating models