2.4 Cooling and Heating Data Sheet in Rated Frequency
Cooling:
Heating:
2.5 Noise Curve
Rated cooling
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°F)
T2 (°F)
80/66.9
95/-
09K
0.9~1.0
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4 Super High
High
52
80/66.9
95/-
12K
0.9~1.0
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4 Super High
High
72
Rated heating
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°F)
T2 (°F)
70/60
19.94/19.04
09K
2.5~2.8
in:167~181.4
out:98.6~113
in:33.8~37.4
out:35.6~42.8
Super High
High
65
70/60
19.94/19.04
12K
2.5~2.8
in:167~181.4
out:98.6~113
in:33.8~37.4
out:35.6~42.8
Super High
High
77
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Indoor side noise when blowing
Outdoor side noise when blowing
Indoor fan motor rotating speed
Compressor frequency(Hz)
Noise/dB(A)
50
60
30
40
20
Low
Middle
High
Super High
40
42
44
46
48
50
52
54
56
20
40
30
50
60
70
80
90
Noise dB(A)
09&12K Cooling
09&12K Heating
GWC09QC-A3DNA1D/I(LC)
GWC09QC-A3DNB2D/I(LC)
GWC09QC-A3DNB4D/I(LC)
GWH09QC-A3DNA1D/I(LC)
GWH09QC-A3DNB2D/I(LCLH)
GWH09QC-A3DNB4D/I(LCLH)
GWC12QC-A3DNA1D/I(LC)
GWC12QC-A3DNB2D/I(LC)
GWH12QC-A3DNA1D/I(LCLH)
GWH12QC-A3DNB2D/I(LCLH)
GWC12QC-A3DNB4D/I(LC)
GWH12QC-A3DNB4D/I(LCLH)
09K