Do install the circuit break. If not, it may cause malfunction. 

of at least 3mm in all poles should be connected in fixed 

wiring.

magnet buckle and heating buckle function, it can protect

the circuit-short and overload.

power supply circuit and circuit break.

3

Precautions

note the following table. Air switch should be included 

Make sure the power supply matches with the 

requirement of air conditioner. Unstable power supply or 

incorrect wiring or malfunction. Please install proper power 

supply cables before using the air conditioner.

An all-pole disconnection switch having a contact separation 

Must follow the electric safety regulations when installing 

the unit.

grounding wire of power socket.

Properly connect the live wire, neutral wire and 

any work related to electricity and safety.

Be sure to cut off the power supply before proceeding 

Including an circuit break with suitable capacity, please 

Air Conditioner should be properly grounded. Incorrect 

Don't use unqualified power cord.

grounding may cause electric shock.

According to the local safety regulations, use qualified 

Installation must be performed by qualified professionals. 

Otherwise, it may cause personal injury or damage.

Attachment

WARNING

Содержание GWC09QC-A3DNA1D/I

Страница 1: ...r choosing our product If you have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper operation please r...

Страница 2: ...D3DNB4D I GWH12QC A3DNB4D I GWC18QD D3DNA1D I GWC18QD D3DNB2D I GWC12QC D3DNA5D I GWC18QD D3DNA5D I GWC09QC D3DNB8D I GWC09QC A3DNB8D I GWC12QC D3DNB8D I GWC12QC A3DNB8D I GWH18QD D3DNB2D I GWH18QD D3...

Страница 3: ...GWH24QE D3DNA5D I GWH24QE D3DNB2D I GWH24QE D3DNB4D I GWH24QE D3DNB8D I GWH24QE D3DNA3D I GWC24QE D3DNA2D I GWH24QE D3DNA2D I GWC24QE D3DNB8D I GWC24QE D3DNA3D I GWC24QE D3DNB2D I GWC24QE D3DNA5D I G...

Страница 4: ...ram 23 Tools for installation 24 Selection of installation location 24 Requirements for electric connection 25 Installation Installation of indoor unit 26 Check after installation 31 Test and operatio...

Страница 5: ...s situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard re...

Страница 6: ...appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory ormental capabilities or lack of experience and know...

Страница 7: ...amage 2 Precautions conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill...

Страница 8: ...fore using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly...

Страница 9: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions wire which can t be used for other purposes The grounding resistance should...

Страница 10: ...onditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the...

Страница 11: ...rent from above graphics please refer to actual products Parts Name Indoor Unit air inlet panel aux button horizontal louver air outlet remote control Actual product may be different from above graphi...

Страница 12: ...r display For some model For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display G W R Power LED color...

Страница 13: ...N TIMER OFF button SLEEP button button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Set temp Out...

Страница 14: ...nditioner will give out a sound Operation indictor is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote contr...

Страница 15: ...button above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner will blow...

Страница 16: ...e indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set...

Страница 17: ...1 TIMER ON TIMER OFF button 12 TIMER ON button TIMER ON button can set the time for timer on After pressing this button icon disappears and the word ON on remote controller blinks Press or button to a...

Страница 18: ...button 2s later the time will change quickly until reaching your required time Press TIMER ON to confirm it The word ON will stop blinking icon resumes displaying Cancel TIMER ON Under the condition...

Страница 19: ...t 8 heating function Note Under 8 heating function fan speed is defaulted at auto speed and it can t be adjusted Under 8 heating function set temperature can t be adjusted Press TURBO button and the r...

Страница 20: ...two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operatio...

Страница 21: ...enance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use v...

Страница 22: ...d then put it in a shady and cool place to dry panel cover tightly The lter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased Aft...

Страница 23: ...nage pipe is damaged 1 Disconnect power supply Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air...

Страница 24: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 25: ...door temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set t...

Страница 26: ...ess devices etc Disconnect power put back power and then turn on the unit again Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing in...

Страница 27: ...can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not please Note service Malfunction analysis When below phenomenon occurs please turn off ai...

Страница 28: ...23 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm Space to the wall Space to the wall At least 15cm...

Страница 29: ...driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Me...

Страница 30: ...er to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with nation...

Страница 31: ...piping hole 2 Open a piping hole with the diameter of 55 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side wit...

Страница 32: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Страница 33: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Страница 34: ...ircuit break should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal with wire clip power co...

Страница 35: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Страница 36: ...ower cord follow the speci cation It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insuf cient cooling heating capacity The dust and sun...

Страница 37: ...l refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional...

Страница 38: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 39: ...suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the por...

Страница 40: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000086...

Отзывы: