2
1
Install indoor unit
mm
0
5
1
m
m
5
5
Φ
m
m
5
5
Φ
mm
0
5
1
Φ55
Install the rear panel
1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the
both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is
taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and
level should be 0 or more, that is good for condensing water drainage.
2.Fix the rear panel on the wall with screws.
(Where is pre-covered with plastic granula)
3.Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an
adult of 60kg, further more, the weight should
be evenly shared by each screw.
Install the piping hole
1.Make the piping hole (Ф55) in the wall at a slight
downward slant to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Install the water drainage pipe
Indoor
Outdoor
Wall pipe
Seal pad
Fig.5
Wall
Wall
Mark on the middle of it
Gradienter
Left
Right
(Rear piping hole)
(Rear piping hole)
Space
to the
wall
above
Space
to the
wall
above
1. Connect the drain hose to the outlet pipe of the indoor
unit.Bind the joint with rubber belt.
2. Put the drain hose into insulating tube.
3. Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain
hose
downward
slightly for smooth drainage of
condensate.
bulge
distortion
outlet pipe of
indoor unit
insulating tube
connected
insulating tube
drain hose
outlet pipe of
indoor unit
drain hose
outlet pipe of
indoor unit
outlet pipe of
indoor unit
rubber belt
rubber belt
rubber belt
Flooded
Note: The insulating tube should be connected
reliably with the sleeve outside the outlet pipe.
The drain hose should be slanted downward slightly,
without distortion, bulge or fluctuation. Do not put