Air Source Heat Pump Water Heater
5
NO.
Safety Notices
Graphic symbol
19
★
It is highly recommended to place the unit where
good ventilation is available.
20
★
Check the safety relief valve for blockage
periodically (about one month) by removing the
hand grip and operate it periodically (about one
year).
21
★
It is a normal phenomenon that the safety relief
valve drips.
22
★
The safety relief valve shall be got through to the
floor drain through a flexible tube.
23
★
The safety relief valve shall be installed properly
with the direction arrow indicated the same direction
as the cold water flow.
24
★
It is recommended to install horizontally the filter
downstream of the main cut-off valve of the user’s
water pipe. Please note that the direction arrow on
the filter shall indicate the direction the same as the
water flow. When it is required to remove impurity
inside the water circuit, open the end cover of this
filter.
Содержание GRS-1.5/TD150ANbA-K
Страница 38: ......