background image

 

 
 
 
 
 
 
 
 
 
 

 

 

Owner's Manual 

Original Instructions 

 

Air Source Heat Pump Water Heater

 

 

Models: 
GRS-1.5/TD150ANbA-K 
GRS-1.5/TD200ANbA-K 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание GRS-1.5/TD150ANbA-K

Страница 1: ...Owner s Manual Original Instructions Air Source Heat Pump Water Heater Models GRS 1 5 TD150ANbA K GRS 1 5 TD200ANbA K ...

Страница 2: ...used for long cut off the power supply please energize and preheat the unit in advance before reusing it 3 Please properly select the model according to actual the using environment otherwise it may impact the using convenience 4 This product has gone through strict inspection and operational test before leaving the factory In order to avoid damage due to improper disassembly and inspection which ...

Страница 3: ...suse of the product 2 Alter change maintain or use the product with other equipment without abiding by the instruction manual of manufacturer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair maintain the unit without abiding by instruction manual or related reg...

Страница 4: ...stallation Diagram 20 5 Electrical Wiring 21 5 1 Electrical Wire Layout 21 5 2 Electrical Wiring and Connection 23 6 Debugging for the complete unit 23 7 Method to Supplement or Discharge Refrigerant 25 7 1 Supplement Refrigerant 25 7 2 Discharge Refrigerant 26 8 Unit Performance 26 8 1 Water Heating Capacity 26 8 2 Operation Performance 27 9 Operation Notices in Winter 27 10 Maintenance 28 10 1 W...

Страница 5: ... hazard or serious injury As for the special places above please adopt special product with anti corrosive or anti explosion function Air source water heater is a thermal storage water heater The user shall open the cold water valve first then adjusting cold and hot water flow to proper water temperature gradually to avoid scald injury If not using the unit in winter in short time please ensure th...

Страница 6: ...2 Don t operate water heater with wet hand Otherwise it may cause electric shock 3 Before installation please see if the voltage of local place accords with that on nameplate of unit and capacity of power supply power cord or socket is suitable for input power of this unit 4 Special circuit must be adopted for power supply to prevent fire Do not use octopus multipurpose plug or mobile terminal boa...

Страница 7: ...n responsible for their safety Children should be supervised to ensure that they do not play with the appliance 10 Earthing the unit must be earthed reliably The earthing wire should connect with special device of buildings If not please ask the qualified personnel to install Furthermore don t connect earth wire to gas pipe water pipe drainage pipe or any other improper places which professional d...

Страница 8: ...n otherwise it would be damaged 16 Keep the chemical spray gas tank or others similar at least 1m away from the unit otherwise it would lead to fire hazards or explosion 17 This series adopts electronic anode for corrosion prevention energize it to allow water tank to assist anode weak current thus protecting inner tank Therefore do not cut off the power of the unit otherwise electronic anode will...

Страница 9: ...e drips 22 The safety relief valve shall be got through to the floor drain through a flexible tube 23 The safety relief valve shall be installed properly with the direction arrow indicated the same direction as the cold water flow 24 It is recommended to install horizontally the filter downstream of the main cut off valve of the user s water pipe Please note that the direction arrow on the filter ...

Страница 10: ... disposal recycle it possibly to promote the sustainable reuse of material resources To return you used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling 27 This unit contains fluorinated gas with greenhouse effect covered by the Kyoto Protocol Maintenance and disposal must be carr...

Страница 11: ...ustable control of the weak current in inner tank it provides stable and overall protection for the inner tank which is corrosion resistant efficiently with service life up to 10 years No replacement is needed which is zero consumption multiple protection for the whole unit to ensure durable use of the system 4 Easy installation Without restrictions of the installation location it is available to ...

Страница 12: ...fter power is on the electron will flow to inner tank forcibly and form an electron oxidation on the surface thus avoiding metal oxidation in inner tank and protecting the effect Corrosion prevention of electron anode has the advantages of long service life no pollution and good self adaptation 2 2 Main parts This air source water heater product and water system pipeline constitute the whole struc...

Страница 13: ... air in the surrounding environment transmit it to the heat exchanger of water tank and then release it to the water inside the water tank for heating water The heating principle for air source water heater and heat pump air conditioner is the same Heat pump air conditioner supplies the absorbed heat from natural environment to indoor air while air source will use that heat to heat domestic water ...

Страница 14: ...ation Level Ⅰ Ⅰ Protection of Ingression ⅠPX4 ⅠPX4 Refrigerant Name R134a R134a Charge kg 0 8 0 8 Outline Dimensions W D H mm 621 561 1760 621 561 2030 Package Dimensions W D H mm 731 717 1845 731 717 2110 Gross Net Weight kg 112 0 92 0 122 5 102 5 Sound Power Level dB A 62 62 Operating Range C 0 45 0 45 NOTES Value obtained with the following conditions Outdoor temperature 20 CDB 15 C WB Water ta...

Страница 15: ...enance center If the user use self prepared materials to install our air source heat pump water heater all losses resulted in pipeline leakage falling off and improper installation which might affect normal operation and usage of air source heat pump water heater Gree shall not be liable 4 The heat pump can operate when the ambient temperature is above 0 C the water heater can only be put indoors ...

Страница 16: ...n Location 1 Suggest installing the unit indoors But do not make the wind blowing to the living room 2 The noise and air flow generated at the air outlet will not influence your neighbors animals and plants 3 Good ventilation is available 4 It is able to withstand the weight and vibration of the unit and it is available for safe installation 5 It is dry but not subject to direct sunlight or strong...

Страница 17: ...Anode Temperature Sensor 2 Cold Water Inlet Figure 4 1 Unit struture size chart Model Parameter GRS 1 5 TD150ANbA K GRS 1 5 TD200ANbA K A mm Φ540 Φ540 B mm 1760 2030 C mm 1206 1476 D mm 186 186 E mm 1032 1302 4 2 2 Installation requirement 1 The unit shall be installed upright on the strong enough balcony or floor Do not point the air outlet of water heater at the upwind direction 2 The unit shall...

Страница 18: ...g in malfunction of water tank 3 The distance between water heater and surrounding wall or other shelter objects can t be too close The installation space should satisfy the installation space requirement Figure 4 2 Installation space requirement 4 When a weather shed is set up to protect the unit be sure heat release and heat absorption by the heat exchange will not be affected 5 The unit shall b...

Страница 19: ...ghtly connected and then led to the floor drain 1 The water may drip from the discharge pipe of the pressure relief device and this pipe must be left open to the atmosphere 2 The pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked 3 How the water heater can be drained 4 The type or characteristics of the pressure relief device and how to ...

Страница 20: ...ot suggested 2 Water inlet and outlet pipe installation Water inlet pipe shall install safety valve filter and cut off valve installation sequence shall accord with unit installation diagram Water outlet pipe shall have at least one cut off valve To drain or clean the water tank add a 3 way and a cut off valve in water outlet of water tank If the water tank is far away from user water use site hot...

Страница 21: ...ur During heating operation process safety valve dripping water is a normal phenomenon of pressure relief Under standby status if the safety valve keeps dripping water please check if water pressure is too high not over 0 7MPa If water pressure is higher than 0 7MPa install stabilizing valve correctly according to 6 Stabilizing valve installation if water pressure is below 0 7MPa please check and ...

Страница 22: ... a Installation method 1 b Installation method 2 c Installation method 3 Figure 4 5 Safety valve installation diagram of water inlet pipe in water tank Material code Name Specification pressure Quantity 07382801 Safety valve G1 2 0 7MPa 1 ...

Страница 23: ...running water first if water pressure is over 0 7MPa add stabilizing valve in waterway otherwise pressure relief on safety valve might occur when the unit is not heated Stabilizing valve direction shall accord with the water tank direction shall be installed between safety valve and filter NOTICE To ensure water safety the PPR pipe length at the water inlet and outlet is determined as per the form...

Страница 24: ...G1 2 NOTICE 1 Dimensions and material for the water inlet and outlet shall be in accordance with the above table The hot water pipe shall be S2 5 wall thickness 2 7mm DN15 outer diameter PPR pipe All used PPR pipes shall comply with GB T18742 When other similar pipes are taken as alternatives refer to the outer diameter and wall thickness stated above When the check valve is used outdoor it should...

Страница 25: ...o perform electric wiring 5 Electrical Wiring 5 1 Electrical Wire Layout 1 This unit is the ClassⅠequipment and shall be grounded reliably to the special ground device by the skilled personnel 2 Ensure that a switch for all pole disconnection is available for the fixed lines and is directly connected to wiring terminals of the power supply Ensure that contactor opening distance on all poles meets ...

Страница 26: ...your local power supply authority to ensure that power network has met the above requirements No requirement for the unlisted product s impedance value of power supply system NOTICE Only copper power cable is allowed and the working temperature shall not exceed the specified set point When the power cable is longer than 15m its sectional area shall be enlarged in case of accidents caused by overlo...

Страница 27: ...th the wiring rules NOTICE This drawing is just for reference Please see the wiring diagram attached to the unit for exact details A power cable rated for 220 240V power supply and equipped with a leakage circuit breaker is supplied with the unit It is not allowed to be installed in the bathroom kitchen balcony and other damp places 6 Debugging for the complete unit After installing waterway syste...

Страница 28: ...here is water leakage in pipeline and joint For initial installation the installation debug personnel shall conduct this operation if the user reuse it after discharging water water input operation is also required for operation 2 Unit energization When the unit is energized you will hear a sound from the buzzer of displayer Observe if the displayer is normal without any error code The displayer h...

Страница 29: ...o fluorine filling nozzle of air valve not tight up then open the valve of refrigerant bottle reopen the valve near the low pressure gauge relief air for 5s then shut down immediately tight up the hose connector of fluorine filling nozzle When pointer of low pressure gauge declines slowly unscrew the valve near low pressure gauge for replenishment refrigerant supplementary diagram is as Figure 7 1...

Страница 30: ...nit Performance 8 1 Water Heating Capacity During heating the unit absorbs heating capacity in the air from outdoor then release it to the water to heat up water on the water tank Once outdoor temperature decreases heating capacity might have certain decay If pressing the Rapid button on displayer it will startup the auxiliary electrical heater of 1 500W to heat with heat pump at this time water p...

Страница 31: ...n 4 Memory function Before the unit is power off the displayer will automatically memorize ON OFF status of the unit when it is re energized wired controller will send ON OFF signal to the unit according to the status memorized before power off to ensure it keeps the original status set by the user 9 Operation Notices in Winter 1 Before starting the unit which has not been used for a long period o...

Страница 32: ...ing water and to reuse the unit again pours water to the water tank fully before starting up Please refer to water input and drainage operation of the water tank Warm hint If it s not convenient for operation or there s hazard please contact the local appointed dealer or appointed service center directly We will appoint profession persons to check debug and clean the unit and discharge water and f...

Страница 33: ...site then reopen the cut off valve in joint 3 way connector repeat the drainage operation close the cut off valve in joint 3 way connector when water discharged is clean 6 Conduct water input for the water tank according to water input operation 7 Water tank cleaning completed and energize it 10 3 Maintenance of Safety Valve During heating if pressure of inner tank of the water tank is too high it...

Страница 34: ...Periodic Check for Electricity Leakage Protection Switch 1 For the unit whose power cord is self equipped with electricity leakage be sure the electricity leakage protection switch before starting up is kept open 2 After the electricity leakage protection switch is operating for a period normally one month press TEST button under closed and energized status to check if the protection switch perfor...

Страница 35: ...ithout enough water might produce high temperature steam or hot water which might cause serious scald Hence guarantee the water tank is filled with water 5 The water heater is equipped with safe relief valve for reliable operation please don t change its location and never block its outlet The pipe should be directly connected to floor drain 6 Never drink the water inside the water tank 7 Children...

Страница 36: ...ase refer to Figure 4 4 connect to suitable discharge location with discharge pipe There is water drained from safety valve During heating if pressure of inner tank of the water tank is too high it will discharge little water to release pressure through safety valve which is a normal phenomenon However if water of big outflow occur in safety valve obviously even result in vibration of pipeline and...

Страница 37: ...he unit is shut down and Fd is displayed on the controller Suction temperature sensor error The unit is shut down and FE is displayed on the controller Upper temperature sensor error on water tank The unit is shut down and FL is displayed on the controller Lower temperature sensor error on water tank The unit is shut down and L6 is displayed on the controller Unit capacity is insufficient The unit...

Страница 38: ......

Отзывы: