Auto

Cool

Dry

Heat

● 

8

1

ON/OFF button

Press this button to turn on the unit. Press this button again to turn off the unit.

2

MODE button

Press this button can your required operation mode in turn. Corresponding indicator 
will be on.

Fan
Only

Auto:

 Under this mode, the unit will operate automatically according to ex-factory

setting. In this case, set temperature cannot be adjusted.

Cool:

 Under this mode, air conditioner operates under cooling mode. Cooling

indicator will be on. Press “Fan Speed” button can adjust the fan speed.

Dry: 

Under this mode, the unit runs in low fan speed for dehumidification and the

corresponding indicator is on; under dry mode, the fan speed cannot be adjusted.

Fan Only:

 Under this mode, air conditioner will not cool or heat, only blow wind.

Fan indicator will be on. Press “Fan Speed” button can adjust the fan speed.

Heat:

 Under this mode, air conditioner operates under heating mode. Press “Fan

Speed” button can adjust the fan speed.(Cooling only unit won’t receive heating
mode signal. If setting heat mode with remote controller, press ON/OFF button
can’t start up the unit.)

Pressing “+” or “-” button once will increase or decrease set temperature by 1°F(°C).
Hold “+” or “-” button for 2s, set temperature on remote controller will change
quickly. Release the button after your required set temperature is reached.

Under timer setting status, after each pressing of “+” or “-” button, time will increase
or decrease 0.5h. Hold “ + ”  or “-” button, 2s later, time displayed on dual-8 nixie
tube will change quickly. Loosen the button until the time is reached to your set
time.

This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.

Introduction for buttons on remote controller 

Note:

3

 + / -

 

button

Содержание GPC07AM-K5NNA2B

Страница 1: ...5NNA2C GPC09AM K5NNA2B Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please conta...

Страница 2: ...Pipe 28 Attached Sheet Electric Schematic Diagram 31 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the envi...

Страница 3: ...components that produced by other manufacturers 6 After verification the problem or dispute is caused by the quality specification or majeure 7 The damage is caused by natural calamities bad using en...

Страница 4: ...floor area m 4 WARNING Appliance filled with flammable gas R290 Appliance shall be installed operated and stored in a room with a floor area The appliance shall be stored in a room without continuous...

Страница 5: ...le the air conditioner by yourself Do not put or hang dripping objects above the air conditioner Keep children from playing or climbing on the air conditioner Children and disabled people are not allo...

Страница 6: ...r conditioner at humid environment During operation close doors and windows to improve cooling effect Please keep air inlet and air outlet clean no obstacles to avoid noise and vibration Please put th...

Страница 7: ...controller NOTICE Heat discharge pipe and other installation accessories can t be discarded 4 1 Controller panel Guide louver 3 Swing louver 4 Castor 5 Filter Joint 7 Heat discharge pipe 8 Window adap...

Страница 8: ...el won t display Under ON status dual 8 nixie tube on control panel will display set temperature under cooling mode while it won t display under other modes Pressing this button can turn on or turn of...

Страница 9: ...eed high speed auto fan low speed Fan button 4 Operation Introduction for Control Panel 6 Sleep button Press sleep button to enter into sleep mode If the controller operates at cooling mode after slee...

Страница 10: ...function Set temperature Operation mode Auto mode Cool mode Dry mode Fan mode Heat mode TIMER ON TIMER OFF 1 On Off button 2 Mode button button 4 Swing button 5 Fan button 6 Sleep button 7 Timer butto...

Страница 11: ...at Under this mode air conditioner operates under heating mode Press Fan Speed button can adjust the fan speed Cooling only unit won t receive heating mode signal If setting heat mode with remote cont...

Страница 12: ...press timer button timer setting status will be quit after 5s If timer is confirmer press this button again to cancel timer 8 Health button Press this button to achieve the on and off of health and sc...

Страница 13: ...ns simultaneously to set the lamp on or off and send the code After being energized the lamp is defaulted on 1 Press the back side of remote controller marked the cover of battery box along the arrow...

Страница 14: ...tioner Clean outer case If there s dust on the surface of outer case please use soft towel to wipe it If the outer case is very dirty such as grease please use neutral abluent to wipe it Clean outer c...

Страница 15: ...1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5 Ch...

Страница 16: ...ether the set temperature is proper Whether door and window are closed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit is...

Страница 17: ...ure In order to prevent cold air air conditioner will delay for a while to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting will resume operation N...

Страница 18: ...in the unit ERROR CODE and high humidity environment if ambient temperature is too high power off the unit and then energize it for operation after the ambient temperature drops to 35 below blocked by...

Страница 19: ...the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other p...

Страница 20: ...wire and grounding wire of power socket 5 Be sure to cut off the power supply before proceeding any work related to electricity and safety 6 Do not put through the power before finishing installation...

Страница 21: ...sory list Tools needed for installation cross screwdriver gauge straight screwdriver scissors saw pencil heat discharge pipe Joint Window adapter top Window adapter bottom remote controller user s man...

Страница 22: ...re Hook Assemble the wire hook at the back of the unit with screws the direction of wire Wind the power cord around the wire hook direction of wire hook is upward direction of wire hook is downward sc...

Страница 23: ...When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge water the unit will turned off about 2min latter and all buttons are invalid Turn...

Страница 24: ...n a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose installation may result in water filling up the...

Страница 25: ...ttom of sash Foam seal B adhesive type 1 Connect the rain guards to the insect guard net Insert all three projections on each rain guard into the holes in the insect guard net 2 Attach the guard combi...

Страница 26: ...panel Exhaust cover 20 5 37 4 37 4 56 7 2 Secure the window panel to the window stool with screws 1 Open the window sash and place the window panel on the window sill 1 Open the window sash and place...

Страница 27: ...nt air and insects from getting into the room 5 Close the window sash securely against the Window panel 7 Attach the bracket with a screw Recommended Please lay a tabular material underneath the windo...

Страница 28: ...seal B adhesive type 1 Connect the rain guards to the insect guard net Insert all three projections on each rain guard into the holes in the insect guard net 2 Attach the guard combined above to the w...

Страница 29: ...anel Inner height of the window 37 4 950mm 56 7 1440mm Use the window panel the adjustment panel and the extension panel Window panel Exhaust cover 20 5 37 4 20 5 37 4 56 7 2 Secure the window panel t...

Страница 30: ...the bracket with a screw Recommended Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep window sill Br...

Страница 31: ...om fix them together press the clasp forcibly in to the groove clockwise clockwise joint window adapter heat discharge pipe 3 Insert joint of heat 4 Lead the exhaust hose outdoors discharge pipe the s...

Страница 32: ...t it with other When installing heat discharge pipe should be as flat as possible Don t prolong heat discharge pipe 29 The discharge pipe is suggested to be installed according to below figure by the...

Страница 33: ...from outdoors 3 Remove the window adapter Pull out and remove the window adapter by pushing down two PUSH markings and slide and close the exhaust cover in the window panel Optional 1 Remove joint Pre...

Страница 34: ...te in cooling mode The Electric schematic diagram are subject to change without notice Please refer to which one on the unit R M OUTTUBE OUTTUBE TEMP RT3 TUBE TEMP TUBE REC RT2 RT1 DISPLAY BOARD SENSO...

Страница 35: ...potentially toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically...

Страница 36: ...all include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactor...

Страница 37: ...inguished remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing If a leakage of refrigerant is found which requires brazing all...

Страница 38: ...mpletion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site Ensure that contamination of different refrigerants does not occur when using charg...

Страница 39: ...order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment tha...

Страница 40: ...600005061860 GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn Web www gree com...