background image

1

The Refrigerant

WARNING

To realize the function of the air conditioner unit, a special refrigerant circulates in

the system. The used refrigerant is the fluoride R32, which is specially cleaned. 

The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion 

under certain conditions. But the flammability of the refrigerant is very low. It can

be ignited only by fire.

Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm

to the ozonosphere. The influence upon the greenhouse effect is also lower. R32

has got very good thermodynamic features which lead to a really high energy

efficiency. The units therefore need a less filling.

Do not use means to accelerate the defrosting process or to clean, other than those

recommended by the manufacture. Should repair be necessary, contact your nea-

rest authorized Service Centre. Any repairs carried out by unqualified personnel

may be dangerous. The appliance shall be stored in a room without continuously

operating ignition sources. (for example: open flames, an operating gas appliance

or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger

than 4m  .
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s

instructions only. Be aware that refrigrants not contain odour. Read specialist’s

manual.

2

Appliance filled with flammable gas R32.

Before install and use the appliance, read the owner’s manual first.

Before repair the appliance, read the service manual first.

Содержание GPAC09D

Страница 1: ...C09D Thank you for choosing our product If you have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper o...

Страница 2: ......

Страница 3: ...tached Sheet Electric Schematic Diagram 26 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or...

Страница 4: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Страница 5: ...t use means to accelerate the defrosting process or to clean other than those recommended by the manufacture Should repair be necessary contact your nea rest authorized Service Centre Any repairs carr...

Страница 6: ...st Do not operate the air conditioner at humid environment During operation close doors and windows to improve cooling effect Please keep air inlet and air outlet clean no obstacles to avoid noise and...

Страница 7: ...on If drainage hose is used ambient temperature can t be lower than 0 Otherwise it will cause water leakage to air conditioner Prohibit inserting any objects into the air conditioner Do not use an ext...

Страница 8: ...r 4 Castor Wire fixing hook 5 Plug of power cord 7 Gastor 8 Air inlet 9 Joint A 10 Heat discharge pipe 11 Joint B C 6 Part s Name 11 10 9 6 7 8 Heat discharge pipe and other installation accessories c...

Страница 9: ...conditioner will give out a sound Meanwhile corresponding indicator on control panel will be bright Under OFF status dual 8 display on control panel won t display Under ON status dual 8 display on con...

Страница 10: ...utton within 10 hours while timer setting will increase or decrease 1 hour by pressing or button beyond 10 hours After timer setting is finished the unit will display temperature if there s no operati...

Страница 11: ...reen 2 1 3 4 5 6 7 1 3 5 2 4 6 7 ON OFF button MODE button button FAN button X FAN button SLEEP button TIMER button Timer on Timer off Sending signal X fan operation Sleep operation Lock Set speed Set...

Страница 12: ...or button for 2s set temperature on remote controller will change quickly Release the button after your required set temperature is reached When setting Timer On or Timer Off press or button to adjus...

Страница 13: ...icon will be blinking Within 5s press or button to adjust the time for Timer On Pressing or button once will increase or decrease the time by 0 5h Holding or button for 2s time will change quickly Re...

Страница 14: ...r won t send signal Note Timer setting range 0 5 24h The interval between two motions can t exceed 5s otherwise the remote con troller will exit setting status Child lock function Temperature display...

Страница 15: ...ries If the display on remote controller is fuzzy or there s no display please replace batteries 1 After putting through the power press ON OFF button on remote controller to turn on the air condition...

Страница 16: ...er Clean outer case If there s dust on the surface of outer case please use soft towel to wipe it If the outer case is very dirty such as grease please use neutral abluent to wipe it Clean outer case...

Страница 17: ...1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5 Ch...

Страница 18: ...ether the set temperature is proper Whether door and window are closed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit is...

Страница 19: ...In order to prevent cold air air conditioner will delay for a while to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting will resume operation No f...

Страница 20: ...ration Water leakage F0 F2 F1 H8 H3 E8 F4 1 Refrigerant is leaking 2 System is blocked 1 Re energize the unit after turning off and pulling out the plug for 30min 2 If there s still malfunction please...

Страница 21: ...fluorescent lamp 4 The appliance shall not be installed in the laundry Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulat...

Страница 22: ...installation Accessory list Tools needed for installation cross screwdriver gauge straight screwdriver scissors saw pencil joint A joint B joint C heat discharge pipe drainage pipe remote controller u...

Страница 23: ...re Hook Assemble the wire hook at the back of the unit with screws the direction of wire Wind the power cord around the wire hook direction of wire hook is upward direction of wire hook is downward sc...

Страница 24: ...age port drainage pipe clip screw Note When using the continuous drainage option from the bottom hole install drainage pipe before using otherwise poor drainage will affect normal operation of the uni...

Страница 25: ...ed inside the chassis and you do not need to discharge the water frequently 2 When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge wate...

Страница 26: ...e hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose installation may result...

Страница 27: ...nt A joint B C joint B C heat discharge pipe 2 Insert joint A of heat discharge pipe the side with TOP is upwards into the groove until you hear a sound 3 Aim the locating pole of joint B of heat disc...

Страница 28: ...arge pipe correct correct correct wrong The length of the heat discharge pipe is less than 1m It is recommended to use it with shortest length the pipe or connect it with other When installing heat di...

Страница 29: ...oint B from joint C 2 Remove joint A Press the clasp and lift joint A upwards to remove it joint B C upwards clasp disassemble joint A would easily cause malfunction should not be over 130cm from floo...

Страница 30: ...normally If ambient temperature is below 16 C the unit can t operate in cooling mode WATER MOTOR ROOM POWER L BN BK N YEGN GN BU WH BU N3 S COMP YEGN C YE CAP K201 AC L COMP AP1 N1 WATER DISP2 RD FAN...

Страница 31: ......

Страница 32: ...66129927686 2 F Shing Dao Industrial Building 232 Aberdeen Main Road Hong Kong...

Отзывы: