Multi Variable Air Conditioners Ducted Type Indoor Unit
3
No.
Name
Appearance
Q'ty
Usage
6
M10 Nut (M10×8.4 Nut)
4
To be used together with the hanger
bolt for installing the unit.
7
M10 Washer (Spring
Washer M10×2.6)
4
To be used together with the hanger
bolt for installing the unit.
8
Insulation
1
To insulate the gas pipe
9
Insulation
1
To insulate the liquid pipe
10
Sponge
2
To insulate the drain pipe
11
Sponge for the fresh air
port
1
Thermal insulation for the fresh air
port
12
Fastener
8
To fasten the sponge
13
Packing collet (installation
cardboard)
1
To drill hole on the ceiling
3.2 Location for Installation
(1) The appliance shall not be installed in the laundry.
(2) The top holder must be strong enough to support unit’s weight.
(3) Drain pipe can drain water out easily.
(4) There is no obstacle at inlet or outlet. Please ensure good air circulation.
(5) In order to make sure the space for maintenance, please install the indoor unit according to the
dimension described below.
(6) Keep the unit away from heating source, inflammable gas or smoke.
(7) This is a concealed ceiling type unit.
(8) Indoor unit, outdoor unit, power cord and electric wire should stay at least 1m (39-3/8inch) from
the TV set and radio. Otherwise, these electrical appliances may have image interference and
noise. (Even if the distance is 1m (39-3/8inch), when there is strong electric wave, noise may
still occur.)
Unit: mm(inch)
Fig.3.2.1