background image

 

 

Preface 

For  correct  installation  and  operation,  please  read  all  instructions  carefully.  Before 

reading the instructions, please be aware of the following items: 

(1) For the safe operation of this unit, please read and follow the instructions carefully. 

(2) During operation, total capacity of indoor units should not exceed the total capacity of 

outdoor units. Otherwise, poor effect of cooling or heating may result. 

(3) Direct operators or maintainers should well keep this manual. 

(4) If this unit fails to operate normally, please contact our service center as soon as possible 

and provide the following information: 

  Content  on  the  nameplate(model  number,  cooling  capacity,  production  code, 

ex-factory date). 

  Malfunction details(before and after the malfunction occurs). 

(5) Each unit has been strictly tested and proved to be qualified before ex-factory. In order to 

prevent units from being damaged or operating normally because of improper 

disassembly, please do not disassemble the unit by yourself. If you need to disassemble 

and check units, please contact our service center. We will send specialists to guide the 

disassembly. 

(6) Under the standby status, the unit will consume a little power for ensuring reliability of 

complete unit, maintaining normal communication and preheating refrigerant. When the 

unit won’t be used for a long time, cut off the power of the complete unit. However, please 

preheat it when operating the unit next time. 

(7) All graphics in this manual is only for your reference. For sales or production reasons, 

these graphics are subject to change by manufacturer without prior notice. 

User Notice 

 

This  appliance  can  be  used  by  children  aged  from  8  years  and  above  and  persons  with 

reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and 

understand  the  hazards  involved.  Children  shall  not  play  with  the  appliance.  Cleaning  and 

user maintenance shall not be made by children without supervision. 

 

Correct Disposal of this product 

This marking indicates that this product should not be disposed with other 

household  wastes  throughout  the  EU.  To  prevent  possible  harm  to  the 

environment  or  human  health  from  uncontrolled  waste  disposal,  recycle  it 

responsibly to  promote the sustainable reuse of material resources. To return 

your used device, please use the return and collection systems or contact the 

retailer  where  the  product  was  purchased.  They  can  take  this  product  for 

environmental safe recycling. 

R410A(R32/125:50/50):2087.5 

 

Содержание GMV-ND22PLS/A-T

Страница 1: ...Air Conditioners please read this owner s manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or visit www gree com...

Страница 2: ...ensuring reliability of complete unit maintaining normal communication and preheating refrigerant When the unit won t be used for a long time cut off the power of the complete unit However please pre...

Страница 3: ...n and Drainage System Testing 12 4 4 Installation of Air Duct 15 4 5 Installation of Wired Controller 18 5 Wiring Work 19 5 1 Connection of Wire and Patch Board Terminal 19 5 2 Power Cord Cnnection 20...

Страница 4: ...eck the power supply carefully This air conditioner must be properly grounded through the receptacle to avoid electric shock The grounding wire shouldn t be connected with gas pipe water pipe lightnin...

Страница 5: ...lack of oxygen Never start or stop the air conditioner by inserting or removing the power cord Do not turn off the air conditioner until it runs for at least 5 minutes Otherwise oil return of the com...

Страница 6: ...off the unit at once and disconnect power supply Then contact GREE service center If the air conditioner continues to operate despite of abnormal condition the unit may be damaged and it may cause ele...

Страница 7: ...ating 20 15 7 6 Indoor Unit Working Temperature Range 16 C 32 C 2 3 Unit Functions Unit Functions Wired Controller XK46 Standard Wired Controller XK49 Optional Remote Controller YAP1F Standard Remote...

Страница 8: ...trol the indoor unit 2 M4X25 Screw Cross recessed small pan head screw 3 To fix the wired controller 3 Drain Hose Assembly 1 To connect with the hard PVC drain pipe 4 Special Nut 1 To be used for conn...

Страница 9: ...rwise these electrical appliances may have image interference and noise Even if the distance is 1m when there is strong electric wave noise may still occur Fig 3 2 Notes Installation of the unit must...

Страница 10: ...is installed in places with intense magnetic field or strong interference it is necessary to use shielded wire 3 3 2 Select communication line for indoor unit and outdoor unit Fig 3 3 2 Wire Type Tota...

Страница 11: ...T 6 1 0 1 0 Notes Use copper wire only as unit s power cord Operating temperature should be within its rated value If the power cord is more than 15m long please increase properly the sectional area o...

Страница 12: ...tric box and below unit s lower level 1 Below are the outline dimension applicable to indoor units of GMV ND22PLS A T GMV ND63PLS A T Fig 4 4 1 Below are dimensions of A B C etc for different models U...

Страница 13: ...260 222 1016 220 1050 695 GMV ND80PLS A T GMV ND90PLS A T 1379 565 1340 655 260 207 1153 220 1188 716 GMV ND100PLS A T GMV ND112PLS A T GMV ND125PLS A T GMV ND140PLS A T 1 Drill bolt holes and install...

Страница 14: ...nger bracket The washer fixing plate will prevent the washer from falling 3 The usage of paper pattern Refer to paper pattern of installation for ceiling opening dimension The center of ceiling openin...

Страница 15: ...rainage pipe should be short and the gradient downwards should be at least 1 2 in order to drain condensation water smoothly 2 The diameter of drainage hose should be bigger or equal to the diameter o...

Страница 16: ...lamp with the distance between screw nut and hose smaller than 4mm metal clamp accessory drain hose accessory Fig 4 3 2 Fig 4 3 3 3 Use sealing plate to make the pipe clamp and hose insulated as shown...

Страница 17: ...ds drainage direction should be at least 1 2 If the raising pipe is vertical with the unit the raising height should be less than 800mm Fig 4 3 9 10 Drain pipes should have a downward slope of at leas...

Страница 18: ...n order to prevent air leakage The design and construction of air duct should comply with national requirements The edge of air return duct is suggested to be more than 150mm away from the wall Add a...

Страница 19: ...utlet and Air return Opening 1 Range of Capacity 2 2 6 3kW Fig 4 4 3 Air Outlet Fig 4 4 4 Air return Opening Model Size of Air Outlet Size of Air return Opening A B C D GMV ND22PLS A T 121 528 580 161...

Страница 20: ...return air is desired just change the place of the rectangular flange and the return air cover plate 3 Connect one end of the return air duct to the return air outlet of the unit by rivets and the ot...

Страница 21: ...f the fresh air duct is not be used 2 Install the round flange so that the fresh air duct can be connected as Fig 4 4 10 3 Sealing and heat preservation should be done for both the air pipe and round...

Страница 22: ...e communication wires should be separated from power cord and connection wire between indoor unit and outdoor unit Adjust the static pressure via wired controller according to site circumstance 5 1 Co...

Страница 23: ...wiring clamp 5 3 Connection of Communication Wire between Indoor Unit and Outdoor Unit or indoor unit 1 Detach the electric box lid 2 Let the Communication cable pass through the wiring through holes...

Страница 24: ...remote controller 3 Wired controller and receiving light board can be installed at the same time When operating through a remote controller both wired controller and the receiving light board can rec...

Страница 25: ...e 2 If the unit used in the environment with much dust please clean it regularly usually once every two weeks 6 2 Maintenance before the Seasonal Use 1 Check if the air inlet and air outlet of indoor...

Страница 26: ...ty Input voltage is too low Defect of main PC board The unit stops after running for a while The inlet or outlet of ODU or IDU are blocked by obstacle Poor cooling effect The filter is dirty Too heavy...

Страница 27: ...Multi Variable Air Conditioners Duct Type Indoor Unit 24...

Страница 28: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...

Отзывы: