background image

12

Light indicates the unit is in the 
temperature or delay Time Set Mode

REF#

BUTTON

FUNCTION

1

 

Power

Turns air conditioner On and Off. 

2

Mode

Press this button to select a mode from the following options: 
AUTO - COOL - ENERGY SAVER - FAN - DRY

3

Fan Speed

Press this button to select desired fan speed:
AUTO - LOW - MED - HIGH

4

Timer

Timer can be set in 0.5 hour increments, below 10 hours. Timer can be set in 1 hour 
increments, above 10 hours. Range is 0.5 to 24 hours. 

ON:

 Timer can be set when unit is OFF. When timer reaches ON, the unit will turn on.

OFF:

 Timer can be set when unit is ON. When timer reaches OFF, the unit will turn off.

5

Filter Check

This light will appear when unit has operated for 250 hours. Clean filter per Maintenance section. After 
filter is cleaned, press Filter Check button to clear.

6

 

COOL or ES Mode:

 Use to set temperature. Pressing (

) or (

) button once will increase 

or decrease set temperature by 1°F.

TIMER Mode:

  Use to increase/decrease time increments by 0.5 hours.

OPERATING INSTRUCTIONS

Function & Control Display

DESCRIPTION

FUNCTION

Auto Fan Mode

In this mode, fan speed will automatically adjust to provide optimum comfort with the set temperature.  
Cannot be used when in FAN only mode.

Cool 

Mode

Air conditioner operates under COOL mode. Cooling indicator will be on. 
Press 

Fan Speed 

button to adjust the fan speed.

Energy 

Saver 

Mode

Air conditioner operates under ES mode. ES indicator will be on. Press Fan Speed button to adjust the 
Fan speed.

Fan Only Mode

Fan Speed button to adjust the Fan speed. Air Conditioner does not cool in this mode.

Dry Mode

Unit runs in low fan speed for dehumidification. DRY Mode indicator will be on. Fan speed cannot be 
adjusted.

Display

Shows the room temperature or time remaining on the Delay Timer. Shows the room 
Temperature while setting the temperature in COOL, DRY*or ENERGY SAVER modes.

Cooling indicator

SE indicatorfan

Fan indicator

Dry indicator

2

3

6

7

Auto speed indicator

High speed indicator
Medium speed indicator
Low speed indicator

1

4

5

Auto
High
Med
Low

Cool
Energy Saver
Fan Only
Dry

Mode

Set

Temp/Time

POWER

Timer

Filter Check

Fan

Speed

Содержание G17-6ESCWAC1

Страница 1: ...erial numbers below for your records Model Serial Date Purchased Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please v...

Страница 2: ...LLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 14 CLEANING MAINTENANCE 15 16 BEFORE YOU CALL 17 19 WARRANTY 20 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please r...

Страница 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Страница 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Страница 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Страница 6: ...for the standard vertical double hung window If you need to install the air conditioner in a narrow window you may not need to use the Flexible Screen sub assembly Please refer to requirement of wind...

Страница 7: ...il Window Unit Window Sill And Sash Seal With Adhesive 2 Flathead screwdriver Foam Top Gasket Without Adhesive Top Mounting Rail Seal Strip Parts List INSTALLATION INSTRUCTIONS Parts and Tools Needed...

Страница 8: ...as shown To install the Flexible Screens ensure that the sides marked LEFT and RIGHT are installed into the left and right side of the unit A Hold Frame with one hand while extending Flexible Screen w...

Страница 9: ...ssary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained 5 6 8 Window Sill Sash Seal With Adhesive Note T...

Страница 10: ...re 10 length Locate the Foam Insulation from the packaging Cut the insulation into a rectangular shape to match the width as measured in figure 10 Remove adhesive from back of Foam Insulation Stick th...

Страница 11: ...and evaporates unwanted moisture without extra cooling Sleep Mode Automatically increases the set temperature 2 after the first hour and another 2 after the second hour This feature limits compressor...

Страница 12: ...increments by 0 5 hours OPERATING INSTRUCTIONS Function Control Display DESCRIPTION FUNCTION Auto Fan Mode In this mode fan speed will automatically adjust to provide optimum comfort with the set temp...

Страница 13: ...e in COOL DRY and ENERGY SAVER mode to maintain the most comfortable temperature Timer Button Press this button to initiate AUTO ON AUTO OFF timer Press this button twice to cancel auto timer i Feel B...

Страница 14: ...to the user s preference Adjust the air frame up or down to direct the air flow according to the user s preference OPERATING INSTRUCTIONS Air Flow Adjustment NOTICE This picture is for reference only...

Страница 15: ...ot of dust in the operation environment then clean more frequently Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check t...

Страница 16: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Страница 17: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Страница 18: ...Codes appear please call Customer Service IF THESE SOLUTIONS FAIL PLEASE CALL 1 866 658 0466 FOR GREE CUSTOMER SERVICE BEFORE YOU CALL MALFUNCTION CODE SOLUTION F1 Please contact Customer Service F2 F...

Страница 19: ...t to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter s and clean Temperature is set too high Turn temperature setting down Air louv...

Страница 20: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Страница 21: ...21 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 68ECWAC...

Отзывы: