SAFETY INFORMATION

 

The power cord with this air conditioner contains a current detection device designed to 

reduce the risk of fire. Please refer to the section “operation of current device” for details. In the 
event that the power cord is damaged, it cannot be repaired. It must be replaced with a power 
cord from the product manufacturer. 

 

NOTE:

 

If you turn off the air conditioner, wait at least three MINUTES before turning it back on.  This 

prevents the unit from blowing a fuse or tripping a circuit breaker. 

Operation of Current Device

The power cord contains a current device that senses damage to the power cord. To test your power cord, do the 

following:
1.  Plug in the Air Conditioner.

2.  The power cord has TWO buttons on the 3-Prong Grounding Plug. Press the TEST button. You will notice a 

click as the RESET button pops out. 

3.  Press the RESET button, and you will hear a click as the button engages. 

4.  The power cord is now supplying electricity to the unit. 

(On some products this is also indicated by a light on 

the 

3-Prong Grounding Plug

)

.

NOTE:

•  Do not use the power cord to turn the unit on or off. 
•  Always make sure the RESET button is pushed in for correct operation. 
•   The power cord must be replaced if it fails to reset when either the TEST button is pushed,  

or it cannot be reset. Please contact Customer Service. 

•   If the power cord is damaged, then it cannot be repaired. It MUST be replaced with a new power cord.  

Please contact Customer Service.

Power Cord with 3-Prong 

Grounding Plug and Current 

Detection Device.

   The power cord is equipped with a 3-Prong Grounding Plug which 

can only be used with a standard 3-prong wall outlet to minimize the 

possibility of electric shock hazard. Where a 2-prong outlet is 

encountered, it is your responsibility to have it replaced with a properly 

grounded 3-prong wall outlet.  

•   Do not use a power cord that shows damage or cracks along the 

length or at the connector. A damaged power cord should be replaced 

with a new cord obtained from the manufacturer. Please contact 

Customer Service for replacement options.  

•   Do not modify power cord length or share an outlet with another 

appliance. This may cause electric shock or fire.  

•   Always use a dedicated power circuit. The voltage on the outlet 

should match the voltage rating on the rating plate.  

•   Do not use the outlet if it is loose or damaged. It may cause electric 

shock.  

•  Never use an extension cord, surge protector, or multi-outlet adapter 

with this unit.

SAFETY INFORMATION

Electrical Information

Do not under any 

circumstances cut, 

remove, or bypass the 

grounding prong

Содержание G17-10ESHWAC-CA

Страница 1: ...erial Date Purchased G17 10ESHWAC CA Window Air Conditioner Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please visit...

Страница 2: ...LLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 14 CLEANING MAINTENANCE 15 16 BEFORE YOU CALL 17 19 WARRANTY 20 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please r...

Страница 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Страница 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Страница 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Страница 6: ...install the air conditioner in a narrow window you may not need to use the Flexible Screen sub assembly Please refer to requirement of window size for details All parts must be secured to firm wood ma...

Страница 7: ...es Remote Control Type B Screws 6 Flexible Screen Panel Seal 2 Flexible Screen 2 Upper Guide Rail Window Unit Window Sill And Sash Seal With Adhesive 2 Flathead screwdriver Foam Top Gasket Without Adh...

Страница 8: ...exible Screens ensure that the sides marked LEFT and RIGHT are installed into the left and right side of the unit A Hold Frame with one hand while extending Flexible Screen with other hand Slide edge...

Страница 9: ...re offset to provide the proper pitch to the rear of 8 cm 5 16 This is necessary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to t...

Страница 10: ...conditioner and the window frame see Figure 10 length Locate the Foam Insulation from the packaging Cut the insulation into a rectangular shape to match the width as measured in figure 10 Remove adhes...

Страница 11: ...and evaporates unwanted moisture without extra cooling Sleep Mode Automatically increases the set temperature 2 after the first hour and another 2 after the second hour This feature limits compressor...

Страница 12: ...ime remaining on the Delay Timer Shows the room Temperature while setting the temperature in COOL DRY or ENERGY SAVER modes Increase Decrease Use to set temperature when in COOL and FAN SPEED mode Pre...

Страница 13: ...cel auto timer i Feel Button i Feel function will activate after pressing this button This will work with the rooms ambient temperature sending the remote programmed thermostat temperature to the unit...

Страница 14: ...ccording to the user s preference Adjust the air frame up or down to direct the air flow according to the user s preference OPERATING INSTRUCTIONS Air Flow Adjustment NOTICE This picture is for refere...

Страница 15: ...a lot of dust in the operation environment then clean more frequently Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Che...

Страница 16: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Страница 17: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Страница 18: ...Codes appear please call Customer Service IF THESE SOLUTIONS FAIL PLEASE CALL 1 866 658 0466 FOR GREE CUSTOMER SERVICE BEFORE YOU CALL MALFUNCTION CODE SOLUTION F1 Please contact Customer Service F2 F...

Страница 19: ...t to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter s and clean Temperature is set too high Turn temperature setting down Air louv...

Страница 20: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Страница 21: ...21 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110316 10WAC CA...

Отзывы: