Gree G16-70ESDEHG-IP Скачать руководство пользователя страница 10

been operating for 250 hours, Filter Cleaning Indicator will be lit up to remind 

7

FILTER Button

Other Instructions

1. Alarm Warning

    If bucket is full or not locked into place for over 3min, buzzer will go off for 10s 

    to remind you to empty bucket or put it back into the correct place.

2. Auto Stop

    When bucket is full, removed or not placed correctly or the humidity is 5%lower 

    than the set humidity, unit will automatically stop.

3. Memory Function

    If power is lost, all of the control settings are remembered. So when power is 

    restored, the unit will start back up in the settings it was in when power was 

    lost.

4. Bucket full light

    This indicates that bucket is full or removed or not placed correctly.

5. Clean the Filter On indicator light

7

When continuous dehumidification mode is selected, the corresponding con-

tinuous dehumidify indicator will be on,the dehumidifier will operate continu-

ously at its maximum dehumidification settings if attached to a hose to drain 

or until the bucket is full.

6

CONTINUOUS Button

Press this button to select different kinds of working mode. After each pres- 

sing of this button, mode will switch among free drying, sleeping space,  

living space, basement and continuous drying modes, and the corresponding 

mode indicator will ON. When free drying, all mode indicators are OFF.

5

MODE Button

Содержание G16-70ESDEHG-IP

Страница 1: ...ease contact the local agent or visit www gree com or sent email to global gree com cn for electronic version Thank you for choosing our product For proper operation please read and keep this manual c...

Страница 2: ...heck Before Operation 4 Operation Instructions Operation Method 5 Drainage Option 8 Maintenance Clean and Maintenance 10 Malfunction Troubleshooting 12 Malfunction Codes 14 Note Graphics in this manua...

Страница 3: ...s situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard re...

Страница 4: ...or above 32 C Allow at least 12 18 inches of air space on all sides of the unit Close all doors windows and other outside openings of the room to improve the working effect Please keep the air inlet o...

Страница 5: ...objects Memory function is included in this dehumidifier When nobody is taking care of the unit please turn it off and remove the power plug or disconnect power Do not repair or disassemble the unit...

Страница 6: ...Parts Name Power Plug Front Side Back Side 3 Air outlet Castors Control Panel Water Bucket Air in grille Cover plate continous drainge Rear case...

Страница 7: ...n both sides of the water bucket and pull it out following the arrow direction moved a little after long time transportation If it s not placed properly move it to the correct position by hand 3 Repla...

Страница 8: ...n water away please install the hose acc ording to section Drainage method Each time pressing the effective button on the control panel will give out a beep sound When power is connected power indicat...

Страница 9: ...it is off press this button and the Timer Indicator will be blink while within 10h pressing button will increase decrease the time by 0 5h decrease the time by 1h When time is set wait for 5s or press...

Страница 10: ...up in the settings it was in when power was lost 4 Bucket full light This indicates that bucket is full or removed or not placed correctly 5 Clean the Filter On indicator light 7 When continuous dehum...

Страница 11: ...connected water will be drained out through it instead of into the bucket 1 Hold the handles on both sides of the water bucket and pull it out following the arrow direction Attention Pull out the buc...

Страница 12: ...bucket from the unit as instructed 3 Thread the drain hose onto the nozzle and make sure it s securely locked 4 Replace the bucket Make sure the drain hose goes through the bucket s drain the hole wit...

Страница 13: ...Water Bucket Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Use soft brush to clean the bucket and then rinse it To remove 1 Direct the rotor shaft of handle to the ho...

Страница 14: ...e air filter with fire or electric hair dryer Otherwise the air filter may be unshaped or caught on fire Don t use dust catcher or brush to clean the air filter Otherwise the air filter may be destroy...

Страница 15: ...perating in a room where temperature is from 5 to 15 C it will start to defrost automati cally Compressor will stop for a brief period of time fan will operate in high fan speed normal operation emitt...

Страница 16: ...ket Bucket has been removed Empty the bucket and replace it Unit can function normally but it can not start up Humidity is set too high If you want the air drier press button to lower the for unit to...

Страница 17: ...perature sensor is damaged Please refer to Chec king Table for Temperature Sen sor Resistance Display board is damaged 2 Tube Temperature Sensor Malfunction F2 Temperature sensor on the evaporator is...

Страница 18: ...4 Freon lacking protection F0 The compr essor stops the fan mo tor keeps on running Refrigerant is leaking System is blocked 5 High tempe rature over oad protect ion H3 Ambient operation condition is...

Страница 19: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000072...