Centralized Controller
28
Auto function: the setting temperature of water heating will be automatically
provided by water heater according to the outdoor ambient temperature, there is no
need to set by the user, and the water temperature cannot be adjusted via
or
buttons.
Sterilization function: it will conduct high temperature sterilization when the
water temperature in the water tank is heated to 65~70
℃
(adjustable) within the
required set time. Press the
button to enter the sterilize page,when the high
temperature sterilization is set to be “once”, then the sterilization will be valid for
once; when the high temperature sterilization is set to be “circular”, the sterilization
will be circularly valid, then it can set the circulated days and presetting sterilization
time. When the sterilization function is activated, the icon will flicker.
Fast function: start up the compressor and electric heating water under the
allowable conditions of outdoor unit, it displays
,the fast water heating function
can be set to be valid for once, when the water tank/hot water generator has
reached to heat preservation status, it displays
,the fast water heating function
will be cancelled for energy saving. After the water heating is closed down, the fast
water heating function is cancelled.
Shield function: it can conduct shield function by pressing
of wired
controller to nullify such operation.
(6) Malfunction View
When the water heater fails to function well, press
to view the information
of malfunctions.