7
Technical Information
Service Manual
Cooling
Outdoor temp.(°C)
Outdoor temp.(°C)
Capacity ratio (%
)
Capacity ratio (%
)
Heating
0%
20%
40%
60%
80%
100%
120%
140%
18
20
25
30
35
40
43
0%
20%
40%
60%
80%
100%
120%
140%
-15
-10
-7
0
2
7
10
15
24
Condition Cooling
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m
Condition Cooling
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m
Condition Heatin
g
Indoor:DB20°C
/WB15°C
Indoor air flow: Super High
Pipe length:5m
Cooling
Outdoor temp.(°C)
Outdoor temp.(°C)
Capacity ratio (%
)
Capacity ratio (%
)
Heating
0%
20%
40%
60%
80%
100%
120%
18
20
25
30
35
40
43
0%
20%
40%
60%
80%
100%
120%
140%
-15
-10
-7
0
2
7
10
15
24
Condition Heatin
g
Indoor:DB20°C
/WB15°C
Indoor air flow: Super High
Pipe length:5m
2.2 Capacity Variation Ratio According to Temperature
07K:
09K:
2. Specifications