background image

Butterfly Series

-22-

Table 11

Description

Part  No.

No.

Qty

 1

Front Grill

22263002

22263002

22263002

22263002

1

 2

Front Plate

20003100

20003100

20003100

20003100

1

 3

Axial Flow Fan

10333002

10333002

10333002

10333002

1

 4

Motor FW20B

FW20B

15013045

15013045

15013045

15013045

1

 5

Motor Support

01703200

01703200

01703035

01703035

1

 6

Condenser  Assy

01103219

01103220

01103218

01103221

1

 7

Rear Grill Assy

11123200

11123200

11123200

11123200

1

 8

Right Side Plate Assy

01303010

01303010

01303010

01303010

1

 9

Top Cover Assy

01253263

01253263

01253263

01253263

1

10

Handle

26233033

26233033

26233033 262330331

1

11

Capacitor  CBB61 1.5uF/450VAC

CBB61 1.5uF/450VAC

33010020

33010020

33010020

33010020

1

12

Electric Box Assy

01413002

01413002

01413002

01413002

1

13

Compressor Capacitor  22.5uF/450VAC

CBB65(22.5uF/450VAC)

 33000002  33000002  33000002  33000002

1

14

Terminal Board

T 3 8 6 A

42011241

42011241

42011241

42011241

1

15

Wire Seat

 24253001  24253001  24253001  24253001

1

16

Wire Clip

 24253002  24253002  24253002  24253002

1

17

Metal Clamp

02143014

02143014

02143014

02143014

1

18

Capillary

03003253

03003255

03003253

03003256

1

19

4-way Valve

/

430004021

/

430004021

1

4-way Valve Fittings

/

43000400

/

43000400

1

20

Clapboard Assemble

01233101

01233101

01233101

01233101

1

C-1RN70H5C

00100354

00100354

/

/

1

21

Compressor And Fittings

C-RV167H01AA

/

/

00100355

00100355

1

22

Valve 1/4"

1/4"

07100149

 07100149  07100149  07100149

1

23

Valve 3/8"

3/8"

07100150

 07100150  07100150  07100150

1

24

Valve Support

01713036

01713036

01713036

01713036

1

25

Metal Base

01203116

01203115

01203117

01203117

1

26

Drainage Tie-in

/

06123401

/

06123402

1

KF-

20W/NA13

The data are subject to change without notice.

KFR-

20W/NA13

KF-

25W/NA13

KFR-

25W/NA13

Содержание Butterfly KF-20GW/NA13

Страница 1: ...3GW A13 KF 26GW A13 KFR 26GW A13 KFR 23GW A13 12405 KF 20GW NA13 KFR 20GW NA13 KF 25GW NA13 KFR 25GW NA13 KF 23GW A13 12206 KF 26GW A13 12206 CE STANDARD 1Ph 220 230V 50Hz R22 1Ph 240V 50Hz R22 CE STANDARD 1Ph 220 230V 50Hz R407C 1Ph 220V 60Hz R22 NOTE MODEL Fig 1 ...

Страница 2: ...n width height depth mm Net weight kg Refrigerant charge kg Length m Outer diameter of connecting pipe Max distance KFR 23GW A13 Cooling Heating 2300 2400 800 850 3 5 3 7 2 87 2 82 KFR 23G A13 KFR 23W A13 770 820 3 4 3 6 R22 0 65 Indoor unit Outdoor unit Connecting pipe Liquid pipe mm Gas pipe mm Height m Length m Model Cooling 2300 800 3 5 2 87 KF 23G A13 KF 23W A13 770 3 4 R22 0 55 KF 23GW A13 T...

Страница 3: ...m Net weight kg Refrigerant charge kg Length m Outer diameter of connecting pipe Max distance KFR 26GW A13 Indoor unit Outdoor unit Connecting pipe Liquid pipe mm Gas pipe mm Height m Length m Model KF 26GW A13 The technical data are subject to change without notice Please refer to the nameplate of the unit 1Ph 220 230V 50Hz 420 1 0 1090 930 13 Cross flow fan 1 97 538 Aluminum fin copper tube 1 5 ...

Страница 4: ...ise dB A Dimension width height depth mm Net weight kg Refrigerant charge kg Length m Outer diameter of connecting pipe Max distance Cooling Heating 1Ph 240V 50Hz 2300 2400 820 800 3 5 3 4 380 1 0 2 82 3 00 KFR23G A13 12405 1080 980 910 13 Cross flow fan 1 97 538 Aluminum fin copper tube 1 5 0 13 MP24GA 2 Controller 3 15A Transformer 0 2A 1 37 710 180 250 7 KFR 23W A13 12405 790 770 3 3 3 3 23 Cap...

Страница 5: ...m Net weight kg Refrigerant charge kg Length m Outer diameter of connecting pipe Max distance KFR 20GW NA13 Indoor unit Outdoor unit Connecting pipe Liquid pipe mm Gas pipe mm Height m Length m Model KF 20GW NA13 The technical data are subject to change without notice Please refer to the nameplate of the unit Cooling 2000 850 3 70 2 35 KF 20G NA13 KF 20W NA13 820 3 57 R407C 0 58 Cooling Heating 20...

Страница 6: ...Fuse A Working capacitor F Noise dB A Dimension width height depth mm Net weight kg Model Input power W Current A L R A A Throttling method Compressor Compressor power W Protector Starting method Working temp Condenser Pipe diameter mm Working area m2 Fan motor speed rpm Type piece Diameter mm Defrosting method Noise dB A Dimension width height depth mm Net weight kg Refrigerant charge kg Length m...

Страница 7: ... depth mm Net weight kg Model Input power W Current A L R A A Throttling method Compressor Compressor power W Protector Starting method Working temp Condenser Pipe diameter mm Working area m2 Fan motor speed rpm Type piece Diameter mm Defrosting method Noise dB A Dimension width height depth mm Net weight kg Refrigerant charge kg Length m Outer diameter of connecting pipe Max distance KF 26GW A13 ...

Страница 8: ...Butterfly Series 9 3 Performance curves Fig 2 ...

Страница 9: ...Butterfly Series 10 Heating capacity change ratio Fig 3 ...

Страница 10: ...Butterfly Series 11 m Fig 4 ...

Страница 11: ...Butterfly Series 12 4 Outlines and dimensions of indoor unit 710 250 180 Back view Ceiling Unit mm Above 4cm Above 5cm Above 7cm Wall mounted frame Fig 5 ...

Страница 12: ...Butterfly Series 13 5 Outlines and dimensions of outdoor unit Hand lift Fig 6 ...

Страница 13: ...Butterfly Series 14 6 Explosive view and spare parts list of indoor unit Model KF R 23G A13 KF R 26G A13 KFR 23G A13 12405 KF R 20G NA13 KF R 25G NA13 23 33 32 31 30 29 28 27 24 26 25 Fig 7 ...

Страница 14: ...20002035 20002035 20002035 1 19 Filter 11122006 11122006 11122006 11122006 11122006 2 20 Remote Controller Y512F 30515009 30515009 30515009 30515009 30515009 1 21 Sheath Of Air Guide Axes 10542011 10542011 10542011 10542011 10542011 3 22 Stepping Motor MP24GA MP24GA 15212102 15212102 15212102 15212102 15212102 1 23 Motor FN13B FN13B 15012038 15012038 15012038 15012038 1 Motor FN13H FN13H 15012065 ...

Страница 15: ...12004 1 18 Front Panel 20002035 20002035 20002035 20002035 1 19 Filter 11122006 11122006 11122006 11122006 2 20 Remote Controller Y512F 30515009 30515009 30515009 30515009 1 21 Sheath Of Air Guide Axes 10542011 10542011 10542011 10542011 3 22 Stepping Motor MP24GA MP24GA 15212102 15212102 15212102 15212102 1 23 Motor FN13B FN13B 15012038 15012038 15012038 15012038 1 24 Motor Clamp 26112014 2611201...

Страница 16: ...Butterfly Series 17 Blank ...

Страница 17: ...Butterfly Series 18 Model KF 23G A13 12206 KF 26G A13 12206 Fig 8 ...

Страница 18: ...006 11122006 2 14 Air Filter Bracket 24222001 24222001 2 15 Guide Louver 26112004 26112004 1 16 Remote Controller Y522F 30515007 30515007 1 17 Indicator Light Ban 22432007 22432007 1 18 Incept Telecontrol Window 22432006 22432006 1 19 Stepping Motor MP24GA MP24GA 15212102 15212102 1 20 Motor FN13F FN13F 15012055 15012055 1 21 Motor Clamp 26112014 26112014 1 22 Terminal Board GT4A3A3 GT4A3A3 420111...

Страница 19: ...Butterfly Series 20 7 Explosive view and spare parts list of outdoor unit Model KF R 23W A13 KF R 26W A13 KFR 23W A13 12405 KF R 20W NA13 KF R 25W NA13 Fig 9 ...

Страница 20: ... Capacitor 30uF 450VAC CBB65 30uF 450VAC 33000037 1 Compressor Capacitor 25uF 450VAC CBB65 25uF 450VAC 33000020 1 14 Terminal Board T386A 42011241 42011241 42011241 42011241 42011241 1 15 Wire Seat 24253001 24253001 24253001 24253001 24253001 1 16 Wire Clip 24253002 24253002 24253002 24253002 24253002 1 17 Metal Clamp 02143014 02143014 02143014 02143014 02143014 1 18 Capillary 03003228 03003229 03...

Страница 21: ...2 1 13 Compressor Capacitor 22 5uF 450VAC CBB65 22 5uF 450VAC 33000002 33000002 33000002 33000002 1 14 Terminal Board T386A 42011241 42011241 42011241 42011241 1 15 Wire Seat 24253001 24253001 24253001 24253001 1 16 Wire Clip 24253002 24253002 24253002 24253002 1 17 Metal Clamp 02143014 02143014 02143014 02143014 1 18 Capillary 03003253 03003255 03003253 03003256 1 19 4 way Valve 430004021 4300040...

Страница 22: ...Butterfly Series 23 Blank ...

Страница 23: ...Butterfly Series 24 Model KF 23W A13 12206 KF 26W A13 12206 Fig 10 ...

Страница 24: ...orCapacitor CBB612 0uF 450V CBB612 0uF 450V VDE 33010025 1 Fan Motor Capacitor 2 5uF 450V CBB612 5uF 450V VDETUV 33010026 1 13 Electric Box Assy 01413002 01413425 1 14 CompressorCapacitor 15uF 450V 15uF 450V VDETUV 33010728 1 CompressorCapacitor 30uF 450VAC CBB6530uF 450VAC 33000018 1 15 Terminal Board T386A 42011241 42011241 1 16 Wire Clip 24253002 1 17 Wire Seat 24253001 1 18 Capacitor Locator 0...

Страница 25: ...Butterfly Series 26 8 Circuit diagram These circuit diagrams are subject to change Please refer to the ones stuck on the machines KF 23GW A13 KF 20GW NA13 KF 26GW A13 KF 25GW NA13 Fig 11 ...

Страница 26: ...Butterfly Series 27 KFR 20GW NA13 KFR 23GW A13 KFR 25GW NA13 KFR 23GW A13 12405 Fig 12 ...

Страница 27: ...Butterfly Series 28 KFR 26GW A13 Fig 13 ...

Страница 28: ...Butterfly Series 29 KF 23GW A13 12206 KF 26GW A13 12206 Fig 14 ...

Страница 29: ...1 the machine runs at the cooling mode Compressor and outdoor motor runs indoor fan runs at the set fan speed b if Tin Tset 1 the machine stops Compressor stops first outdoor motor stops after 15 seconds indoor motor runs at the set fan speed c if Tset 1 Tin Tset 1 keep the previous state 2 in this mode the reversing valve is inactive the temp setting range is from 16 to 30 3 Protect function a an...

Страница 30: ...is inactive the temp setting range is from 16 to 30 3 Anti freezing protection If compressor has runs 6 minutes and detects Teva 0 compressor stops and outdoor mo tor stops after 15 seconds indoor motor runs at low speed after 3 minutes delay and Teva 10 it will be back to its original state 3 heating mode 1 the working conditions and control measures a If Tin Tset 2 it goes into heating mode reve...

Страница 31: ...nuous 1 minutes it begins to defrost indoor motor reversing valve and outdoor motor will stop after 15 seconds when Tcon 10 or defrosting lasts for 10 minutes outdoor motor and reversing valve becomes active indoor motor will run as the anti cool air condition then it cycles again recalculates the compressor s running time again g noise eliminated protection When you use RUN STOP button to switch ...

Страница 32: ...ion O close the air outlet b When machine works it turns to the max Air output position D c In swing state the louver swings between position L and position D d When the machine is switched off it is back to position O e When the machine is running and the swing is off the louver stops at position E O L E D 2 beeper When PCB becomes active or receives the signal from the remote controller the beep...

Страница 33: ... mode a In cooling or dehumidifying mode 1 hour after you set the sleep timer Tset will add 1 automatically 2 hour after you set the sleep timer Tset will add 2 automatically b In heating mode 1 hour after you pset the sleep timer Tset will lower 1 automatically 2 hour after you set the sleep timer Tset will lower 2 automatically c In auto mode when you set the sleep mode the set temp will not cha...

Страница 34: ...TECHNICAL SERVICE MANUAL Butterfly Series GREEELECTRICAPPLIANCES INC OFZHUHAI JinjiWestRd QianshanZhuhai GuangdongChina ...

Страница 35: ...e s customers and distributors would find it a very handy source of technical information of our products Technical Support Department GREE ELECTRIC APPLIANCES INC OF ZHUHAI Nov 2002 Editor In Chief Chen Jianmin Compiler Chen Zhian Ouyang Jun Tian Guoku Yang Rong Jia Tianwei Cao Xuan Wang Min Proofreader Wang Li Yang Meng He Jiefeng Zhang Hongwu Wang Wenbin Deng Changrong Xiao Kai Zhu Longxing Des...

Страница 36: ...ance curves 9 4 Outlines and dimensions of indoor unit 12 5 Outlines and dimensions of outdoor unit 13 6 Explosive view and spare parts list of indoor unit 14 7 Explosive view and spare parts list of outdoor unit 20 8 Circuit diagram 26 9 PCB function manual 30 ...