DC INVERTER MULTI VRF CONTROL
54
NOTE!
This type of remote control is a kind of general use remote control that is suitable for several
types (function) of air conditioner units. Please understand that the functions and buttons that are
not suitable for this air conditioner will not be introduced.
TIMER
ONOFF
ON/0FF
ANION
TIMER OFF
TIMER ON
MODE
LIGHT
SLEEP
SAVE
HUMID
AIR
HR.
LIGHT
AUTOFAN
SWING HUMID
AUTO
SWING
SAVE
OPER
AIR
FAN
Liquid crystal displayer
It shows all set contents.
SLEEP button
Press the button to set SLEEP
mode, and stop when repressed.
When the sleep mode is in the
cool and dry mode, the set
temp. will increases 1~2
℃
during the set time, then the
unit will operate according to
the temp.. When sleep mode is
in the heat mode, the set temp.
decreases 1~2
℃
during the set
time, then the unit will operate
according to the set temp..
Temp./Timer button
When the unit is operating, increase 1
℃
by pressing "+" button once, and
decrease 1
℃
by pressing "-" button
once. The indoor temp. can be set in
the range of 16-30
℃
.
Press the "Timer OFF/TIMER ON"
button at operating/ stopping to set the
off/on time. Press "Timer OFF/TIMER
ON" once to increase 0.5 hour for the
set time. The Max.value of setting time
could be 24 hours
,
when repressed it
the setting time will be canceled.
Operation procedure
Normal procedure
1. Press ON/OFF button after connected with the power, then the unit is operating.
2. Press MODE button to choose the need operation mode.
3. Press FAN button to set the fan speed.
4. Press +/- button to set the need temp.
Selectable procedure
5. Press SLEEP mode to set the sleep state.
6. Press TIMER OFF button to set the set time.
Note: When the operating mode selected by the indoor unit is clash with the one selected by the
outdoor unit, the remote controller will display the operating clash after 5 seconds and the power
light will flicker, then the indoor unit turns off. At this time, the units will become normal after the
operating mode of the indoor unit is changed to cooperate with the outdoor unit. Cool mode can
cooperate with dry mode, and fan mode can cooperate with any mode.
Содержание GMV(L)-Pd100W/NaB-K
Страница 1: ...1 DC INVERTER MULTI VRF Service Manual GREE ELECTRIC APPLIANCES INC OF ZHUHAI ...
Страница 4: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 1 PRODUCT ...
Страница 40: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 37 CONTROL ...
Страница 41: ...DC INVERTER MULTI VRF CONTROL 38 CONTROL 1 OPERATION FLOWCHART ...
Страница 43: ...DC INVERTER MULTI VRF CONTROL 40 1 2 Heating Operation ...
Страница 70: ...DC INVERTER MULTI VRF CONTROL 67 2 Frame Diagram of System Net 上 WC ...
Страница 90: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 87 INSTALLATION ...
Страница 115: ...DC INVERTER MULTI VRF INSTALLATION 112 ...
Страница 159: ...DC INVERTER MULTI VRF MAINTENANCE 156 MAINTENANCE ...
Страница 179: ...DC INVERTER MULTI VRF MAINTENANCE 176 ...
Страница 212: ...DC INVERTER MULTI VRF MAINTENANCE 209 2 GMV L R90T Na K GMV L R112T Na K GMV L R125T Na K ...
Страница 216: ...DC INVERTER MULTI VRF MAINTENANCE 213 2 GMV L R40P Na K GMV L R45P Na K GMV L R50P Na K ...
Страница 218: ...DC INVERTER MULTI VRF MAINTENANCE 215 3 GMV L R56P Na K GMV L R63P Na K GMV L R71P Na K GMV L R80P Na K ...
Страница 222: ...DC INVERTER MULTI VRF MAINTENANCE 219 5 2 3 Wall Mounted Type Unit 1 GMV L R22G NaB K GMV L R28G NaB K ...
Страница 224: ...DC INVERTER MULTI VRF MAINTENANCE 221 2 GMV L R36G NaB K GMV L R45G NaB K ...
Страница 226: ...DC INVERTER MULTI VRF MAINTENANCE 223 3 GMV L R50G NaB K GMV L R56G NaB K ...
Страница 228: ...DC INVERTER MULTI VRF MAINTENANCE 225 4 GMV L R71G Na K GMV L R80G Na K ...
Страница 230: ...DC INVERTER MULTI VRF MAINTENANCE 227 5 GMV L R22G NaC K GMV L R28G NaC K ...
Страница 232: ...DC INVERTER MULTI VRF MAINTENANCE 229 6 GMV L R36G NaC K GMV L R45G NaC K ...
Страница 237: ...DC INVERTER MULTI VRF MAINTENANCE 234 2 GMV L R71Zd Na K ...
Страница 240: ...DC INVERTER MULTI VRF MAINTENANCE 237 3 GMV L R90Zd Na K GMV L R112Zd Na K GMV L R125Zd Na K ...