7
Screw
ST4x16
Srcrew ST4x8
Airflow plate
1.3
In case that the opening height of mantel is a little
larger, first attach the fixing brackets to the firebox
with ST4x8 screws, then use ST4x16 screws to attach
brackets to the mantle.
1.4
Attach the airflow plate to the firebox with ST4x8
screws.
Pin
Magnet
1.5
Install the trim onto the insert by locating the pegs on both sides and inserting them into the receiving clips
on the front of the fireplace. Lightly push the trim bottom to fit onto the firebox. The built-in magnets should hold
the front flush. Installation is completed.
OPERATING
This appliance can be operated by both remote control and manual button. Once the unit has been properly
connected to a grounded electrical outlet, turn on the main power switch located on the bottom and right hand
side of the appliance. A beep should be heard when the power is first applied.
CAUTION!
The unit’s power cord must be connected to a properly grounded and protected 120V
outlet. Always use ground fault protection where required by the electrical code.
WARNING!
Do not operate the unit if it is damaged or has malfunctioned. If you suspect the unit is
damaged, please call a qualified service technician to inspect and to replace any part of the electrical
system If necessary.
NOTE!
To use both remote and manual function. As the main power swi
tch must be in “ON” position.
Pegs
Magnets