11-58
ENGINE
AC GENERATOR
3EN0208
3EN0209
7EL0011
7EL0012
7EL0012
STATOR
(1)
Conduct on stator examination over the stator and confirm
whether the conduction exists with the lead-wire of the winding,
if not, replace the stator assembly.
(2)
Check the grounding of stator winding. Confirm whether con-
duction exists between the winding and stator iron core, if yes,
replace the stator assembly.
RECTIFIER
(1) Check the positive rectifier
Check whether conduction exists between the positive rectifier
and the wiring terminals of stator windings with a multimeter. If
conduction exists in two direction , the diode is breakdown, the
rectifier assembly should be replaced.
(2)
Check the positive rectifier
Check whether conduction exists between the negative rectifier
and the wiring terminals of stator windings. If conduction exists
in two direction, the diode is breakdown, the rectifier assembly
should be replaced.
(3)
Check diodes group (3 diodes)
Connect the two ends of the diode to the ammeter, check whether
these three diodes are switched into conduction.
If conduction doesn
t exists bidirectioinally, the diodes are
damaged, and the radiator assembly should be replaced.