YP1630F-1630 and YP1630F-1670
Maintenance and Lubrication
Great Plains
| 401-832M | 2018-07-31
91
Seed Plate Maintenance
Inspect seed plates for wear and damage. See
“
” on page 60 for plate
removal.
Place a straightedge across the planting face of the
plate. If the gap between the top outer edge of the plate
and the straightedge is greater than
1.9 mm (0.075 inches,
5
64
inches), replace the plate.
Inspect plates for damage. The plate depicted has
chipped ridges (probably from being dropped on a hard
surface). Wear less severe than this can cause doubles.
Inspect plates for wear. Sharp edges of pockets and
grooves tend to wear first.
If there is any seed dust or treatment build-up in the cell
pockets
, or in the seed guide grooves
, clean the
disks and re-inspect.
Cleaning and Storing Seed Disks
Use warm or hot water, mild soap, and a sponge or soft
brush to remove build-up.
If plates are washed, allow them to dry completely prior
to storage.
Retain original shipping cartons for plate storage.
Otherwise, store them on edge (and not leaning), or
stacked horizontally on a spindle, to eliminate any risk of
warps. Any seed residue on plates may attract pests.
Fully enclose dry plates to prevent rodent damage.
Air Box Residue Clean-Out
Planting in extremely dusty conditions, particularly dusty
and humid conditions, or otherwise sticky soils, can lead
to air residue build-up inside the airbox. This residue can
cause seed delivery blockages.
Refer to Figure 98 and Figure 99 (Figure 98 depicts a
partially and a completely plugged agitation port, and
build-up in the RH plenum chamber)
Whenever opening the airbox clean-out door
, inspect
the agitation ports
. If any are partially or completely
blocked, follow the clean-out instructions on this page.
Seasonally, remove the inspection ports on each of the
airbox, and inspect plenum chambers 1 (LH) and
16 (RH). If any build-up is observed, follow the more
comprehensive inspection steps and clean-out
instructions on this page.
1.
Spot the planter at a suitable location for clean-out
and follow the parking instructions (page 45).
2.
If seed is loaded, close the slide gate for the hopper
or bulk seed box.
3.
.
Possible Chemical Hazard:
Wear gloves when washing plates. Avoid spray. Do not wash
plates where food is prepared, or where cookware or
dinnerware is washed. Seed plates will have talc and graphite
residue, and may have residues of hazardous seed treatments.
Figure 97
Damaged Seed Plate
34474
3
2
1
Agricultural Chemical Hazard:
Follow material supplier recommendations carefully. Handle
the meter as if it were treated seed. use supplier-recommended
cleaning agents. Any seed treatment build-up inside a meter is
likely to be at a higher concentration than on the actual seed.
Figure 98
Residue in Air Box Plenum
36443
36442
Содержание YP1630F-1630
Страница 134: ...Table of Contents Index Table of Contents Index...
Страница 140: ...Great Plains 401 832M 2018 07 31 Table of Contents Index 136 YP1630F 1630 and YP1630F 1670 Table of Contents Index...
Страница 141: ...Table of Contents Index Table of Contents Index...
Страница 142: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index...