The table below is a general summary of gate
settings.
Seed Pool Slopes
The best seed pool slope results in the most
consistent seeding with minimal skips and doubles.
The illustrations below are found to be the best seed
pool slopes for sample seeds.
Adjust the seed inlet gate if the suggested setting
does not work for your seed.
For medium size and smaller seeds that flow easily,
the slope runs from just above the 8:00 position on
the housing wall, down to one or two seeds deep at
the base of the rear strip brush (1).
For medium size and larger, or heavily treated
smaller seeds that flow less easily, the slope runs at
or slightly above the 8:30 position on the housing
wall, down to three to six seeds deep at the base of
the rear strip brush (1).
Keep the top left/rear end of the pool below the 9:00
position; meter horizontal center
-
line.
In general, the seeds at the base of the strip brush
need to be deep enough that no air escapes, and
that just enough seeds are present to begin
populating the cells.
Seed Meter Operation
1. Install disks for your crop/population range
according to the Material Rate manual and the
instructions beginning on page 39 of this manual.
2. Open the gate at the planting rows to the
recommended initial setting from the seed rate
charts.
3. Operate the fan to achieve the suggested air
pressure.
4. With all rows primed, rotate meters one turn to fill
the cells to the edge of the drop brush. Rotate the
drive shaft (top forward) with a 7/8 inch wrench,
or raise and rotate the ground drive wheel (top
forward).
5. Leave the fan running to keep seed in top cells.
6. Install rain covers.
Begin planting. Meter operation is automatic from
this point on.
Setting
Setting Typically Used For
X
Closed - row shut
-
off, meter refill
|
Small seeds, such as milo, with little or
no treatments
||
Small treated seeds and edible beans
such as soybeans
|||
Corn, round popcorn
||||
Large corn, heavily treated corn
O
Wide open - clean
-
out
69650
8:00
1
68650A
8:30
1
68650B
8:30
1
Содержание PL5700
Страница 120: ...Great Plains 411 681M 04 08 2021 113 PL5700 Planter Table of Contents Index Specifications Topcon XD and XD Plus ...
Страница 122: ...Great Plains 411 681M 04 08 2021 115 PL5700 Planter Table of Contents Index Specifications ...
Страница 130: ...Great Plains 411 681M 04 08 2021 123 PL5700 Planter Table of Contents Index Pre Delivery Instructions ...
Страница 146: ...Great Plains 411 681M 04 08 2021 139 PL5700 Planter Table of Contents Index Warranty ...
Страница 149: ......
Страница 150: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 ...