Great Plains
| 166-207M | 02/26/2019
88
NTA907HD and NTA3007HD
Adjustments
Bypass with
LS or PFC Closed Syste
ms
Turn the adjustment knob counter-clockwise to increase
flow.
Turn the adjustment knob clockwise to decrease flow.
Turning it fully clockwise stops all bypass flow.
Failure to use the bypass valve
on load-sensing tractors
may cause major tractor damage.
7.
Adjust down-pressure before adjusting bypass.
8.
With tractor at half throttle, adjust tractor flow-control
valve so that openers raise and lower at a
reasonable speed. Keep tractor at one-half throttle
for the remaining step.
The faster openers raise and lower, the greater
potential for oil heating, premature wear or tractor
damage. The higher the bypass pressure, the greater
the potential for oil heating and premature tractor
damage. At the same time, for proper opener
operation the bypass valve must be set at least 20 bar
(300 psi) above the opener down-pressure setting
when the tractor is at one-half throttle. Therefore, you
should set the bypass valve as low as possible while
staying at least 20 bar (300 psi) above the opener
down pressure setting.
9.
Slowly open the bypass valve until the down-
pressure gauges just start to decline.
10. Turn the bypass knob one turn in the closing
direction.
11. Lock the knob at that setting.
While 140 bar (2100 psi) is a good starting point for
setting the bypass valve, if you consistently operate the
drill with low opener down pressure you can set the
bypass valve below 140 bar (2100 psi). If you
consistently operate the drill with very high opener down
pressure, you may need a bypass-valve setting above
140 bar (2100 psi).
Figure 93
Bypass Adjustment
29422
Содержание NTA3007HD
Страница 2: ...Great Plains 166 207M 02 26 2019 Table of Contents Index ii 166 207M Table of Contents Index ...
Страница 4: ...2SF24 and 2SF30 ...
Страница 177: ...Table of Contents Index Table of Contents Index ...
Страница 178: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index ...