795-93851
7 of 48
12/23/21
Assembly
After removing the Handi-Kleen from its shipping carton remove any shelves or loose internal parts from
the tank (FIGURE 1(A)) and place tank on its side and assemble legs (FIGURE 1(B)) on the
outside
of
tank brackets (if placed on inside of brackets, holes will not align). It is recommended that the flattened
shipping carton be placed under the tank while assembling the legs to avoid scratching the paint and that
a minimum of two assemblers be employed for this task. Securely tighten all 16 screws (FIGURE 1(C))
into the weldnuts on the tank making sure to include all flat washers (FIGURE 1(D)). [On PL424 there is
only one set of legs. One leg runs the full width of the tank at each end.] Turn unit upright. Install the Handi-
Kleen in a convenient location close to an electrical outlet or compressed air supply, away from open
flame or sparks. Check and tighten all fittings before filling with solvent. Liquid level should remain under
the high-level line. Do NOT overfill. Keep cover closed when not in use to reduce evaporation of cleaning
fluid. The reflective white cover aids visibility when open.
FIGURE 1
Automatic Safety Cover
Open the automatic Safety Cover (FIGURE 2(E)) on your Handi-Kleen and you will notice that it lifts
simply and easily with one hand. There is nothing to connect or disconnect to open or close the cover.
Your Handi-Kleen cover is equipped with a two-way gas spring (FIGURE 2(L)) that also incorporates a
fusible link (FIGURE 2(G)). When open, the cover mechanism supports the cover at a slightly forward
angle. This angle
is necessary to assure the cover’s fusible link will operate in the unlikely event of fire in
the tank. In the event of a fire, the fusible link will melt at 165°F permitting the lid to slam shut, reducing
oxygen supply to the fire.
REF.
DESCRIPTION
QTY.
A
TANK ASSEMBLY
1
B
LEG EXTENSION
4
C
M/S RD HD 10-32 X 1/2
16
D
FLAT WASHER #10
12