Water chiller - only for ENERGY machines
Never operate the LS100 ENERGY/EX ENERGY machine without a properly operating water
chiller that is correctly configured, installed and maintained in good working order.
In order to protect the chiller pump, it is strictly prohibited to operate it without
demineralised water in the tank. To avoid damaging the pump, it is important to fill the
tank before using it for the first time.
•
It is important to check that the demineralised water level is always adequate. Cooling capacity begins to
decline when the demineralised water level falls below the green area (NORMAL) on the gauge.
•
Never drain the water tank while the chiller is in operation.
•
Ensure that the air intake and air outlet are well ventilated. There must be a clearance of at least 8 cm
(3.150 in) at the air intake and of 30 cm (11.811 in) at the air outlet.
• Beware of water condensation. In areas of higher ambient humidity and when the temperature of the water
is below room temperature, condensation forms on the water pipes and cooled components. In this event,
it is advisable to increase the water temperature or to warm up the pipes and cooled components.