Gravely Promaster 310 Скачать руководство пользователя страница 8

 

GB - 8

 

UNCLOGGING GRASS CATCHER

 

If hose or grass blower gets clogged, stop forward 
motion and allow unit to clear itself. If unit will not clear 
itself, unclog the hose/grass blower manually as 
instructed below.

To unclog:

1. Stop unit engine and remove ignition key. Wait for 

all moving parts to stop.

Stop grass catcher engine, wait for all moving 
parts to stop and disconnect spark plug wire.

2. Loosen hose clamp on hose.

3. Remove hose from grass blower.

If clog is in hose:

1. Remove clogged grass.

2. Reinstall hose and tighten hose clamp.

If clog is in grass blower:

1. Remove hose adapter.

2. Clear grass from blower.

3. Reinstall hose adapter and hose and tighten hose 

clamp.

 

OPERATING TIPS

 

Cut grass when it is dry.

Cut grass in two passes when cutting thick, long 
or wet grass. Make the first cut higher than 
desired. Make the second cut at desired height.

Always use full throttle when bagging.

Clean deck after each use to reduce clogging.

Gravely Dealers will provide any service or 
adjustments which may be required to keep your unit 
operating at peak efficiency.

 

MAINTENANCE SCHEDULE

 

The chart below shows the recommended 
maintenance schedule that should be performed on a 
regular basis.

* Change engine oil according to manufacturer’s 
recommendations. See engine manual for specific 
instructions.

** See engine manual for schedule and specific 
instructions.

 

CHECK FASTENERS

 

Be certain that all hardware is tight before each use. 
Pay special attention to the guards and safety shields.

 

WARNING: 

 

MOVING PARTS can cut or 

amputate body parts.

NEVER attempt to clear grass pump while 
engine is running.

ALWAYS stop unit and grass catcher engines, 
remove key, and wait for moving parts to stop.

Sharp edges can cut. Moving parts can cut off 
fingers or a hand. Wrap blade(s), wear sturdy 
gloves and use extreme caution when 
working near blades or impeller.

 

WARNING: 

 

PINCH POINT! Use extreme 

caution when unclogging grass blower. 
Impeller can cut or pinch your hand, even 
when not in operation. Wear sturdy gloves 
when working near impeller.

 

WARNING: 

 

Impeller blades can cut or 

amputate fingers or hands. Block impeller 
blades to prevent rotation before proceeding.

MAINTENANCE

WARNING: 

AVOID INJURY. Read and 

understand 

Maintenance and Service

 in 

Safety 

section before attempting any 

maintenance.

MAINTENANCE SCHEDULE

Service Performed

Each

Use

Every 10 

hrs.

Check Fasteners

Inspect Bagger Parts

Clean Unit

Check Engine Oil

Change Engine Oil

*

Check Belt

Lubricate Unit

Check Spark Plug

**

Содержание Promaster 310

Страница 1: ...or Parts Manual Model 890015 08493200A 12 03 Supercedes 08493200 Printed in USA Promaster 310 Grass Catcher NOTE Installation requires a separate mower boot kit p n 04916000 for 60 decks p n 04916100...

Страница 2: ...arranty period will be honored whether or not the product registration card is returned Keep a proof of purchase if you do not register your unit Customer Note If Dealer does not register your product...

Страница 3: ...List for Safety Decal locations Danger To Avoid Serious Injury Caution Grass Catcher Boot Danger Rotating Blades Boot Caution Rotating Blades SAFETY DANGER IMMINENTLY HAZARDOUS SITUATION If not avoide...

Страница 4: ...r alcohol Safe operation requires your complete and unimpaired attention at all times NEVER allow anyone to operate this unit when their alertness or coordination is impaired Wear adequate safety gear...

Страница 5: ...making repairs adjusting or when clearing debris ALWAYS block wheels Know all jack stands are strong secure and will hold weight of unit during maintenance ALWAYS keep protective structures guards an...

Страница 6: ...the inlet on the grass catcher cover item 29 Raise the ring and pull the cover inside the ring Fold the edge of the cover around the ring and secure with the snaps on the cover 8 Put one end of the h...

Страница 7: ...to OFF Turn grass catcher engine switch to OFF BAGGING Starting IMPORTANT ALWAYS start grass catcher engine before starting unit engine 1 Start grass catcher engine per engine manual instructions 2 Se...

Страница 8: ...ce schedule that should be performed on a regular basis Change engine oil according to manufacturer s recommendations See engine manual for specific instructions See engine manual for schedule and spe...

Страница 9: ...er to the power unit to loosen the belt Move it away from the power unit to tighten the belt 7 Tighten jam nut and engine bolts 8 Replace belt guard LUBRICATE UNIT Every 10 hours and before storage Gr...

Страница 10: ...GB 10 CATCHER ASSEMBLY Model 890015 PF2100...

Страница 11: ...ng Center 38 16 29 08944900 1 Cover Grass Catcher 30 05958400 2 Bolt Hex 38 16 x 2 50 Grade 5 31 05963300 1 Bolt Hex 38 16 x 2 00 32 08942700 1 Bracket Tube 33 08981100 1 Bushing 385 x 625 x 1 00 34 0...

Страница 12: ...t Steel 1 015 x 1 5 x 125 3 21082200 1 Spacer 4 05416000 2 Bearing Ball 1 0 x 2 0 x 56 5 04914851 1 Weldment Fan Housing 6 05234600 1 Decal Danger 7 03021500 1 Blade Fan 8 06529800 4 Nut Locking Cente...

Страница 13: ...must transport the product to and from the place of warranty repair Product Registration Returning the product registration card to Gravely will enable the company to contact the registrant with repai...

Страница 14: ...GRAVELY A Division of Ariens Company 655 West Ryan Street P O Box 157 Brillion WI 54110 0157 920 756 2141 Fax 920 756 2407 www gravely com...

Отзывы: