7. System settings
The necessary settings must be specified
on site when the system is put into operati-
on for the first time.
You can use the system settings to adapt the
chronostat to suit your specific requirements.
Refer to Page 29 for information concerning
inputs (Parameter settings)
Factory settings
Heating or cooling mode
The set value for temperature 1 is active
(factory setting 5 °C provides protection
against freezing)
The system is switched off if TEMP 1 is active
in AUTOmatic or continuous temperature
mode. The same applies to HOLIDAY mode.
There is no protection against
freezing.
Proportional control response
Simple control response
(similar to that of a bimetal controller)
28