product data sheet
Our customer support and professional services offerings ensure optimal system performance and maximize uptime. These services include call centers staffed around the clock, com-
missioning, professional training courses, and technical maintenance programs and service agreements.
www.grassvalley.com/support
cUSTOmER SUppORT & pROFESSiONAl SERvicES
ORdERiNg iNFORmATiON
Frames, Fans and Power
Supplies
TRX-DV-33128
Trinix NXT system 128 chassis with one
PS, one Broadlinx
™
, two fan modules
TRX-DV-33256
Trinix NXT system 256 chassis with one
PS, one Broadlinx, three fan modules
TRX-DV-33512
Trinix NXT system 512 chassis with
PS-chassis, two PS, one Broadlinx, six
fan modules
TRX-PS-33100
Trinix NXT system power supply: 128
chassis
TRX-PS-33200
Trinix NXT system power supply: 256 and
512 chassis
I/O & Matrix
TRX-SI-33110
Trinix NXT system SD input board –
32 inputs
TRX-HI-33200
Trinix NXT system HD/SD input board –
32 inputs, dual-rate equalization
TRX-HI-3G
Trinix NXT system 3G input board –
32 inputs, automatic equalization
TRX-VI-33100
Trinix NXT system variable input board –
16 HD/SD/AV and 16 HD/SD signals
TRX-SO-33110
Trinix NXT system SD output board –
32 outputs, non-reclocked
TRX-HO-33120
Trinix NXT system HD/SD output board –
multi-rate reclocker
TRX-HO-3G
Trinix NXT system 3G output board –
32 outputs
TRX-DM-33100
Trinix NXT system matrix board –
128x128 for use with 128 and 256
chassis
TRX-DM128R-3G
Trinix NXT system matrix board –
128x128 redundant for use with 128 and
256 chassis. Supports 3 Gb/s
TRX-DM-128-3G
Trinix NXT system matrix board –
128x128 for use with 128 and 256
chassis. Supports 3 Gb/s
TRX-DM-33512
Trinix NXT system matrix board –
256x256 for use with 512 chassis
TRX-DM256-3G
Trinix NXT system matrix board –
256x256 for use with 512 chassis.
Supports 3G
Accessories
TRX-CTRL-CPL
CPL control
TRX-CTRL-XPT
XPT control
TRX-BL-33000
Trinix NXT system Broadlinx software
board – NIC, sync, output monitor
TRX-PE-33016-1
Trinix NXT system port expander – 16
port; 2x2. SD/HD
TRX-PE-33008-1
Trinix NXT system port expander – 8 port;
4x1. SD/HD
TRX-MK-33000
Trinix NXT system mounting kit for port
expanders (fits 16 PEs)
TRX-FM-33000
Trinix NXT system fan module
TRX-PE2x2-3G
Trinix NXT system port expander – 16
port; 2x2. SD/HD/3G
Operating Current:
128x128 frame: approx. 5.36A @ 100V,
•
approx. 2.23A @ 240V
256x256 frame: approx. 9.36A @ 100V,
•
approx. 3.90A @ 240V
512x512 frame: approx. 19.08A @
•
100V (9.54A per supply); approx. 7.63A
@ 250V (3.82A per supply)
Inrush Current:
128x128 frame: 49.05A
•
256x256 frame: 55.0A
•
512x512 frame: 45A per supply
•
Hold-up Time:
Minimum 20 ms at full
load
Conducted Emissions:
Per FCC Class B,
EN55022 Class B
Power Supply DC Output
Voltage:
+48 (±0.5) VDC
Current:
128x128 frame: 12.5 A/supply
•
(full redundancy)
256x256 frame: 26 A/supply
•
(full redundancy)
512x512 frame: approx. 26 A/supply
•
(full redundancy)
Current Sharing:
Yes, maximum 20%
differential unbalance
Ripple/Noise:
<200 mV p-p
DC Power Input
Input Voltage Range:
42-54 VDC
Operating Current:
128x128 frame: approx. 9.5A @
•
48 VDC
256x256 frame: approx. 16A @
•
48 VDC
512x512 frame: approx. 34A @
•
48 VDC
Inrush Current:
128x128 frame: 15A
•
256x256 frame: 21A
•
512x512 frame: approx. 25A
•
Alarm
The relay connector is a BNC type and
meets SMPTE 269M-1999
Environmental
+0°C to +35°C (+32°F to +95°F)
Physical Characteristics
512 x 512 Frame Dimensions
Main chassis:
Height: (28 RU) 1245 mm, 49 in.
•
Width: 483 mm, 19 in.
•
Depth: 445 mm, 17.5 in.
•
Power supply chassis:
Height: (4 RU) 178 mm, 7 in.
•
Width: 483 mm, 19 in.
•
Depth: 533 mm, 21 in.
•
256 x 256 Frame Dimensions
Height: (15 RU) 667 mm, 26.25 in.
•
Width: 483 mm, 19 in.
•
Depth: 445 mm, 17.5 in.
•
128 x 128 Frame Dimensions
Height: (8 RU) 356 mm, 14 in.
•
Width: 483 mm, 19 in.
•
Depth: 445 mm, 17.5 in.
•
MK-33000 Mounting Kit
(for port expansion)
Height: (8 RU) 356 mm, 14 in.
•
Width: 483 mm, 19 in.
•
Depth: 100 mm, 4 in.
•
SpEciFicATiONS (cONT.)
© Copyright 2011 Grass Valley USA, LLC. All rights reserved. Grass Valley, CleanFlow, Broadlinx, Encore, Jupiter, NetCentral, NetConfig, and Trinix are
trademarks of GVBB Holdings S.a.r.l. All other tradenames referenced are service marks, trademarks, or registered trademarks of their respective companies.
Specifications subject to change without notice.
RMC-4003D-4