Rear Interface Connections

Rear Interface Notation Guide

Electrical HD-SDI Input

A  High  Definition  Serial  Digital  electrical  input
though a 75

 BNC connector is denoted in the way

shown  opposite.  The  “  H  ”  denotes  the  High
Definition  element  and  the  “  n  ”  is  the  connection
number for that particular rear interface.

Electrical HD-SDI Output

A  High  Definition  Serial  Digital  electrical  output
though a 75

 BNC connector is denoted in the way

shown  opposite.  The  “  H  ”  denotes  the  High
Definition  element  and  the  “  n  ”  is  the  connection
number for that particular rear interface.

Standard Input

Electrical HD-SDI

Used On : SHDSDA1S-S1

    SHDSDA1E-S1

The  high  definition  serial  digital  electrical  input  is
connected to a 75

 BNC connector. The connector

is  shown  opposite  and  is  labelled  H1  on  the  rear
panel.

Standard Outputs

Electrical HD-SDI

Used On : SHDSDA1S-S1

    SHDSDA1E-S1

The  high  definition  serial  digital  electrical  output  is
available  from  eight  75

  BNC  connectors,  each

providing  identical  outputs.  These  connectors  are
shown below and are labelled H2H3H4 H5H6,
H7, H8 and H9.

       Note…

The connector at the middle of the backpanel is not
used  with  this  main  board  but  could  be  used  if  a
dual channel main board is inserted (see Technical
Profile, OPTIONS)
.

Содержание SHDSDA1

Страница 1: ...ON TO THIS OPERATION MANUAL 2 SCOPE OF THIS OPERATION MANUAL 3 MODULE DESCRIPTION 3 FEATURES 4 TECHNICAL PROFILE 5 INPUT 5 OUTPUTS 5 INDICATOR LEDS 5 Standard 5 Enhanced 5 ROLLCALL 5 OPTIONS 5 REAR INTERFACE CONNECTIONS 7 REAR INTERFACE NOTATION GUIDE 7 STANDARD INPUT 7 STANDARD OUTPUTS 7 ROLLCALL MENU SYSTEM 8 ROLLCALL MONITORING FEATURES 9 ...

Страница 2: ... software programs which are displayed on the screen such as icons screen display looks etc Reproduction or disassembly of embedded computer programs or algorithms is prohibited No part of this publication may be transmitted or reproduced in any form or by any means electronic or mechanical including photocopy recording or any information storage and retrieval system without permission being grant...

Страница 3: ...etailed performance information can be obtained via the RollCall interface Two levels of monitoring sophistication are available to the user A standard operational level is available on all boards covering parameters ranging from voltage supply status to the presence of an input signal The optional enhanced monitoring level provides a comprehensive analysis of the incoming HD SDI signal such as CR...

Страница 4: ...locked HD SDI data outputs n Can equalise over 100m of cable n Alarm functions for poor quality input signals and device malfunction n Stand alone or RollCall operation n Incoming signal analysis available as an option it includes CRC status Line standard Frame Rate Error rate Note RollCall TM enabled for remote system control monitoring ...

Страница 5: ...e time 20 80 Fall time 20 80 Difference 270ps 270ps 100ps Return loss 15dB INDICATOR LEDS Not available to the Operator Standard Power Power supplies valid Fault Board fault Enhanced Monitoring Option CPU Valid CPU activity PLL Lock Output locked to input standard CRC Error Data error Line Indicates line standard Frame Indicates frame rate Prog Int Indicates progressive or interlaced frames RollCa...

Страница 6: ...on one IN eight OUT the middle BNC not being used A dual channel version of the DA card is also available order number SHD_SDA2x S2 which contains two separate four output amplifiers A dual channel DA also has a 10 BNC rear interface card two lots of 1 IN four OUT The only difference between the rear interface cards for the two types of DA is in the backpanel labelling Mechanically these two diffe...

Страница 7: ...nt and the n is the connection number for that particular rear interface Standard Input Electrical HD SDI Used On SHDSDA1S S1 SHDSDA1E S1 The high definition serial digital electrical input is connected to a 75Ω BNC connector The connector is shown opposite and is labelled H1 on the rear panel Standard Outputs Electrical HD SDI Used On SHDSDA1S S1 SHDSDA1E S1 The high definition serial digital ele...

Страница 8: ...sure a range of monitoring information is available via RollCall External Monitoring Description General alarm Input power fault or overcurrent trip or system failure Supply voltage levels Actual voltage levels Board temperature Actual board temperature CRC Status Line Standard Frame Rate Bit error rate Error rate over defined time period ...

Страница 9: ...alue in this field is a guide to the strength of equalisation that is being applied to the input signal for longer cable runs The lower the value the less equalisation is being employed It is intended as a guide for troubleshooting the system It should be noted that when an equalisation of 100 is shown it doesn t necessarily mean that the maximum input cable length has been reached As soon as CRC ...

Страница 10: ...Record Date Version No Issue No Change Comments 16 06 01 1 1 First draft document Issued 051001 1 2 Edited current feature list Only states features that are present in current release A1 0 000 New issue released 030402 1 3 New monitoring features added New issue released ...

Отзывы: