Start NetCentral Lite monitoring software
32
PVS 2000 Installation Guide
23 February 2004
Adding the PFR 500, PFR 600, or PFR 700 RAID storage device
This procedure explains how to add the PFR500, PFR600, or PFR700 Fibre Channel
RAID Chassis to the NetCentral device list. This step is required in order to monitor
the RAID chassis.
NOTE: This step is not required for the PFC500 Fibre Channel RAID Chassis
since it is monitored in-band through the Profile XP Fibre Channel connection.
To add the PFR500, PFR600, or PFR700 RAID storage chassis to the device list:
1. In the NetCentral main menu, click
File | Add Device
.
2. In the Add Device dialog box, enter the IP address or host name for RAID
Controller A, then click
OK
. You can use the following default address if you have not
modified network settings: controller A = 192.168.0.11.
NetCentral contacts RAID Controller A, and adds it to the device list. The RAID
Controller is labeled using the controller IP address or the host name if network
name resolution is setup for the Profile XP system. (Refer to “Setting up a simple
network” in the Profile XP System Guide.)
3. Repeat step 1 and step 2 for RAID Controller B, if installed. You can use the
following default address if you have not modified network settings: controller B =
192.168.0.12.
4. Refer to the Profile XP Service Manual for information on using NetCentral Lite
monitoring software.
Содержание Profile XP PVS1000
Страница 16: ...16 PVS2000 Installation Guide 23 February 2004 ...
Страница 22: ...Create a video file system 22 PVS2000 Installation Guide 23 February 2004 ...
Страница 28: ...Set up PFR500 or PFR600 network settings 28 PVS2000 Installation Guide 23 January 2004 ...
Страница 44: ...Select an RS 422 control protocol 44 PVS2000 Installation Guide 23 February 2004 ...
Страница 46: ...46 Grass Valley Product Support 23 February 2004 ...