background image

3922 496 49931 August 2014 v12.0

Software v28

GAIN

BLACK

EXTENDER

GAMMA

GAMMA

FLARE

FLARE

SKIN

SKIN

PANEL

LOCK

WHITE

BALANCE

BARS

SKIN

GAMMA

KNEE

COLOR

BLACK

FLARE

EXP.

TIME

GAIN

FILTERS

DETAIL

CALL

FILES

RECALL

AUTO

SETUP

FREE

PREVIEW

EXIT

PREV.

TOGGLE

NEXT

CAMERA 4

OCP 400

User’s Guide

Operational Control Panel

Содержание OCP 400

Страница 1: ...K EXTENDER GAMMA GAMMA FLARE FLARE SKIN SKIN PANEL LOCK WHITE BALANCE BARS SKIN GAMMA KNEE COLOR BLACK FLARE EXP TIME GAIN FILTERS DETAIL CALL FILES RECALL AUTO SETUP FREE PREVIEW EXIT PREV TOGGLE NEXT CAMERA 4 OCP 400 User s Guide Operational Control Panel ...

Страница 2: ...Operation of this product in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Copyright Copyright Grass Valley Nederland B V 2014 Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authori...

Страница 3: ...ton 13 1 5 10 Call button 13 1 5 11 Using the menu panel 13 Chapter 2 Configurations 2 1 Studio configuration 15 2 2 Dual camera configuration 16 2 3 Single camera configuration 16 Chapter 3 Setup 3 1 Installation 19 3 2 Checking system status 19 3 3 Setting up the OCP 20 3 3 1 Setting the OCP control level 22 3 3 2 Camera assignment 22 3 3 3 IP and Ethernet configuration 23 3 3 4 Display and butt...

Страница 4: ...nu 38 4 4 7 Copy Files menu 39 4 4 8 Card menu 39 4 4 9 Partial file recall 40 4 4 10 Recalling standard files 40 4 5 Adjusting video parameters 41 4 5 1 Skin button 41 4 5 2 Setting Skin detail 42 4 5 3 Gamma button 43 4 5 4 Knee button 44 4 5 5 Color button 45 4 5 6 Black button 46 4 5 7 Flare button 46 4 5 8 Exposure time button 47 4 5 9 Gain button 47 4 5 10 Filters button 47 4 5 11 Detail but...

Страница 5: ...ology This program accepts any Grass Valley branded equipment Upon request a Certificate of Recycling or a Certificate of Destruction depending on the ultimate disposition of the product can be sent to the requester Grass Valley will be responsible for all costs associated with recycling and disposal including freight however you are responsible for the removal of the equipment from your facility ...

Страница 6: ...power supply of the installation the proper functioning of the protective earth lead of the installation needs to be verified Whenever it is likely that safe operation is impaired the apparatus must be made inoperative and secured against any unintended operation The appropriate servicing authority must then be informed Warnings Warnings indicate danger that requires correct procedures or practice...

Страница 7: ...2 Features Uses IP connectivity off the shelf IT network infrastructure over standard IEEE 802 3 10 100 Mb Ethernet Supports C2IP camera control interface protocol supported by all Grass Valley cameras Integrates with other Grass Valley broadcast products and network tools provides remote diagnostics for camera and transmission operation Improved ergonomics and large flexibility comfortable slimli...

Страница 8: ...be available The values available are also camera dependent The menu system only displays the relevant items In the tables on the following pages that list menu items the Level column indicates the control level at which an item is displayed An S simple indicates an item that is always shown A B basic indicates items that are shown in addition to simple items when the control level is set to basic...

Страница 9: ...ls for gain gamma and skin relevant indicator lights R G and B controls for black level flare skin relevant indicator lights Lens indicators displays the iris value or the master black value Extender lights when lens extender is in use Iris Master black Preview move the joystick up and down to change the iris opening turn the lower part of the knob to vary the master black level push the top of th...

Страница 10: ...u can find more information about file handling in the section Using files of this guide Note Note Analogue values are being regarded as changed when they vary more than 10 of their reference value Note Note Functions that are blocked or disabled by another function or that are not part of the current function set simple basic or full will not be indicated non standard even if they are changed 1 5...

Страница 11: ...s the top of the knob to get a preview of the connected camera signal Turn the lower knob to vary the master black level Move the joystick up and down to open and close the iris The joystick direction range and sensitivity can be set in the OCP setup menu Tension adjustment When the joystick s movement becomes too loose or too tight it may be necessary to adjust its tension spring Use a long Torx ...

Страница 12: ...rmation about the OCP setup menu The following settings can be selected Upper default all buttons in the upper operation field stay locked Joystick master black and iris control functions stay locked Matching six colour matching rotary controls in the middle section stay locked GAIN BLACK EXTENDER GAMMA GAMMA FLARE FLARE SKIN SKIN PANEL LOCK WHITE BALANCE BARS SKIN GAMMA KNEE COLOR BLACK FLARE EXP...

Страница 13: ...tasks of the menu panel are to provide access to parameters for setting up the OCP the XCU Base Station and the camera to display function menus and values when a direct video parameter button is pushed to display the status of a set of functions Selection buttons The function of the four arrow buttons in the centre of the menu panel is determined by the item appearing next to them on the display ...

Страница 14: ...v12 0 Chapter 1 Introduction Opening menu pages There are several ways of opening a menu page You can use the SETUP button the FILES button the RECALL STD button the video parameter buttons Push an activated button to exit that particular menu function ...

Страница 15: ... 400 control panels are connected to the C2IP camera control network The IP address and other options for the Ethernet connection can be set up in the OCP Setup menu XCU Base Station n C2IP Camera Control Ethernet Infrastructure OCP 400 n Studio camera n OCP 400 1 Tally signal XCU Base Station 1 Studio camera 1 XCU Base Station 2 Studio camera 2 ...

Страница 16: ...rolled in an absolute manner so e g the colour bar or optical filters of both cameras will be set to the same value when controlled from an OCP in multi camera mode In case of potmeter functions e g iris gains blacks the behaviour is different In this case both cameras will receive the same relative updates so any offsets between their values will normally remain intact 2 3 Single camera configura...

Страница 17: ...OCP 400 Operational Control Panel User s Guide v12 0 17 Chapter 2 Configurations ...

Страница 18: ...18 OCP 400 Operational Control Panel User s Guide v12 0 Chapter 2 Configurations ...

Страница 19: ... power supply unit with the OCP 400 3 2 Checking system status To check that XCU Base Station and camera are connected correctly go to the Diag menu in the setup menu Push the SETUP button to open the menu Push the SELECTION button to choose the Diagnostics menu The diagnostics menu appears Push NEXT and PREV to navigate through the different pages Menu Selections Function Level Possible values Se...

Страница 20: ...nostics S No camera DC Power Short etc Diagnostics page 2 Cam Pack Camera package version S Last 4 digits of Package 12nc Version Camera package version S v0x 0y BS Pack XCU Base Station package version S Last 4 digits of Package 12nc Version XCU Base Station package version S v0x 0y Diagnostics page 3 Cam SW Camera Software 12NC S Status Camera Software Status S BS SW XCU Base Station Software 12...

Страница 21: ... display contrast level B 0 99 50 Buzzer When switched on a buzzer signal sounds when a CALL signal is received from the camera B On Off Txt Bright Sets brightness of dot matrix text displays B 1 20 20 OCP setup page 4 Tally Leds Selects Tally LEDs intensity B Low Medium High Full Text Leds Sets rotary text LEDs intensity B 0 99 LED Low Sets button Low Level illumination B 0 99 LED High Sets butto...

Страница 22: ...that you want to control using the assignable rotary control Press SELECT to confirm OCP setup page 7 CamNum2 Select secondary camera number 1 99 SELECT Connects to the secondary camera Press button to connect to the selected secondary camera Multi Cam Switches multi camera mode on or off On Off OCP setup page 8 ProgFunc1 Assigns a function to programmable function1 Disabled Gain ND Up Dwn FX Up D...

Страница 23: ...Possible values IP Config page 1 IP Mode IP address assignment F Auto Manual Apply Sets IP mode F Press button to activate the new IP settings Subnet Mask Subnet mask address F 255 255 0 0 IP Config page 2 IP Byte 1 IP address 1st byte F 1 250 192 IP Byte 2 IP address 2nd byte F 0 255 168 IP Byte 3 IP address 3rd byte F 0 255 0 IP Byte 4 IP address 4th byte F 1 254 2 Menu Selections Function Level...

Страница 24: ...red when the Reset OCP item is selected When the OCP is powered up or reset a connection to the last camera number used is made The default values for the camera and XCU Base Station parameters are stored in the camera and XCU Base Station default files The camera parameters and their values that are shown on the OCP depend on the camera connected to OCP If you select a different camera number a d...

Страница 25: ...s on the XCU Base Station text and monitoring output Menu Selections Function Level Possible values BS setup page 1 Monitoring Monitoring output selection S CVBS R G B Y EXT1 EXT2 Y EXT1 Y EXT2 MENU Go to BS menu control S BS setup page 2 H Phase Adjustment H Phase B 0 99 SC Coarse Adjustment SC Phase coarse B 0 90 180 270 SC Fine Adjustment SC Phase fine B 0 99 BS setup page 3 Notch Lvl Notch Dep...

Страница 26: ...4 9 10 9 16 9 Off SD Ratio Select SD aspect ratio S 4 3 16 9 Ratio Sel Aspect ratio selection S Extern MCP Camera setup page 4 Freeze Freeze picture S On Off LEDWallFlt Turns LED Wall filter on or off LDX cameras S On Off Reverse Scan Switches reverse scan on or off S On Off Mode Selects Reverse Scan Mode S Horizontal Vertical Both Camera setup page 5 Lens Ctrl Selects lens control point S Local R...

Страница 27: ...io 1 Level S 22 to 64dB Audio2 Lvl Set Audio 2 Level S 22 to 64dB Camera setup page 12 V Timing Vertical timing adjustment S 1 1125 depends on video mode Hph Coarse Hphase coarse adjustment S 0 2749 depends on video mode CVBS SCph CVBS Subcarrier phase adjustment S Hph Fine Hphase fine adjustment S Camera setup page 13 Fan Ctrl Remote camera fan control S Off Max Var Cam Temp Shows camera temperat...

Страница 28: ...1 Shading Turns shading on or off F On Off Shading page 2 R SAW H Sets the horizontal sawtooth value for red F 0 99 50 R PAR H Sets the horizontal parameter for red F 0 99 50 R SAW V Sets the vertical sawtooth value for red F 0 99 50 R PAR V Sets the vertical parameter for red F 0 99 50 Shading page 3 G SAW H Sets the horizontal sawtooth value for green F 0 99 50 G PAR H Sets the horizontal parame...

Страница 29: ...indow in the camera viewfinder The button lights 2 Press the WHITE BALANCE button a second time to start the measurement process The button flashes If the measurement is successful the light in the button and the measurement window are switched off If the measurement is unsuccessful the light in the WHITE BALANCE button is orange If the button is pressed during the measurement process or at the en...

Страница 30: ...and recalled to immediately change a complete set of parameters Standard values Different set of standard values can be recalled to immediately reset the video parameters Direct video parameter buttons A direct video parameter button when selected brings its associated menu to the display where you can navigate select and vary the applicable values Programmable functions Up to 6 functions can be a...

Страница 31: ...er wheels color and saturation settings camera type and video mode Status page 2 Displays information about knee gamma black stretch skin detail and video aspect ratio Status page 1 Status page 2 Status page 3 Programmable page 1 Programmable page 2 Transmission diagn page EXIT TOGGLE PREV NEXT ND 1 4 CTEMP Clear SATUR LDX 80 P 3200K 1080i60 90 Filter wheel 1 position Filter wheel 2 position Color...

Страница 32: ...all functions on a page are disabled the entire page is not shown EXIT TOGGLE PREV NEXT GAIN 50 50 F8 0 BLACK DTL MBL IRIS R50 G50 B50 14 1dB R50 G50 B50 GAIN Gain R G and B values Black R G and B values Detail function and value Variable gain function and value Master black and value Iris function and value EXIT TOGGLE PREV NEXT Gain 0 Gain ND Down ND Up Clear Programmable function 1 up control F...

Страница 33: ... or transmission system for more information about these diagnostic indications TOGGLE PREV NEXT EXIT C BS Signal NoSignal BS C Signal Cable Length 95 Cable OK Cable length indication Cable quality from XCU Base Station to camera Signal quality from camera to XCU Base Station Cable quality from XCU Base Station to camera TOGGLE PREV NEXT EXIT Signal NoSignal FibB Cable ERROR Signal FibA Cable OK S...

Страница 34: ...ons on the OCP push the FILES button to open the menu Push the NEXT button to open the store page and then select a memory position The values are stored in this position Note Note When a scene file is recalled the values only take effect if the camera is not On Air Menu Selections Function Level Possible values Scene files page 1 RECALL 1 Recall Scene File 1 S Ready Failed RECALL 2 Recall Scene F...

Страница 35: ...OCP File Management can be used you need to format an OCP storage card Empty cards can be obtained from Grass Valley in a set of 10 cards LDK 5210 Follow these steps for to format a card 1 Insert the card into the slot at the top of the OCP and push the FILES button 2 Push the NEXT button until the OCP 400 Card item appears 3 Select the Format option and wait a few seconds 4 Your OCP storage card ...

Страница 36: ...s are camera scene files They are followed by the card scene files stored on your OCP storage card Use the left menu buttons or the assignable rotary control to scroll up and down the list Camera scene files are indicated with a camera icon and card scene files with a card icon The arrow indicates the currently selected scene file Select RECALL to recall the settings in the selected scene file Sel...

Страница 37: ... move the cursor back and forward Use the TOGGLE button to select a different character set abc 123 ABC Select CLEAR to clear the file name Select OK to use the new filename The file will be added to the card and the current settings are stored in this file Select CANCEL to cancel the operation and return to the Recall Store menu Note Note File names can have up to ten characters TOGGLE PREV NEXT ...

Страница 38: ...mera scene files can not be deleted 4 4 6 Read Write attribute menu Select a scene file from the list Select ATTRIB to change the Read Write status of the selected scene file A scene file can have a Read Only R status and a Read Write R W status Note Note Read Write attributes of a camera scene file can not be changed TOGGLE PREV NEXT EXIT Scam1 CardScene1 SCam2 new file RENAME DELETE Go to the Re...

Страница 39: ... are overwritten When the item New File is selected in the destination field the source file is copied to a new file You will be prompted to enter a file name Refer to the Recall Store menu for the naming procedure 4 4 8 Card menu This menu displays the name of the inserted OCP storage card the number of scene files stored on the card and the percentage of space used Select FORMAT to format a card...

Страница 40: ... are restored to the user s reference settings While the FILES button is pressed the last recalled or restored file is displayed on the menu panel Note Note A partial recall of the Gain function set will also recall the RGB Gain values and a partial recall of the Black function set will also recall the RGB Black values and the master black value 4 4 10 Recalling standard files Push the RECALL STD ...

Страница 41: ... 3 SET 3 Go to SET SKIN 3 menu B SET 1 Go to SET SKIN 1 menu B SET 2 Go to SET SKIN 2 menu B SKIN page 2 Flw Zoom Skin detail follows Lens zoom B On Off Menu Selections Function Level Possible values SET SKIN1 page 1 SKIN SEL Select SKIN B Off 1 2 3 1 2 1 3 2 3 1 2 3 SKIN1 LVL Sets SKIN1 detail level B 0 99 SKIN VIEW Turns on to view the selected SKIN detail area B On Off SKIN Auto Starts Auto Ski...

Страница 42: ...3 1 2 3 SKIN2 LVL Sets SKIN detail level B 0 99 SKIN VIEW Turns on to view the selected SKIN detail area B On Off SKIN AUTO Starts Auto Skin procedure B Off Win Run Fail SET SKIN2 page 2 COLOR2 R Adjust Skin 2 Color R Level B 0 99 COLOR2 B Adjust Skin 2 Color B Level B 0 99 WIDTH2 R Adjust Skin 2 Width R Level B 0 99 WIDTH2 B Adjust Skin 2 Width B Level B 0 99 SET SKIN2 page 3 ViewInsert Skin view...

Страница 43: ...alue below 50 to soften the selected area Increase the value above 50 to add extra detail Repeat the steps for the Skin 2 and Skin 3 position if required Set the menu item Skin View to On to show the affected area The color range set by the automatic procedure can be adjusted manually if required Manual skin detail Set the skin detail color range manually as follows 1 In the Skin menu select item ...

Страница 44: ...off F On Off Shadow Sets contrast for Shadows area F 0 99 Midtone Sets contrast for Midtone area F 0 99 Highlight Sets contrast for Highlight area F 0 99 Menu Selections Function Level Possible values Knee page 1 Knee Sel Knee function S Auto Var Off Kn Point Knee point as video level S 0 90 Kn Fade Fades between linear Fade 99 and Var Knee compression Fade 0 S 0 99 Kn Max In Sets maximum input vi...

Страница 45: ...ource selection B Y RGB Max Knee page 3 WhiteClip Switches White Clipper on or off B On Off Wclip Lvl Sets White Clipper Level B 0 99 Menu Selections Function Level Possible values Color page 1 Col Temp Selects color temperature memory S 3200K 5600K 7500K AW1 AW2 AWC FL Var Ctemp Selects variable color temperature S 2000K 21000K Saturation Sets saturation Level S 0 99 Tint Green Magenta tint adjus...

Страница 46: ...f S On Off Color Sets Color S 0 360 Width Sets Color Width S 22 5 360 Hue Sets new Hue value for the selected color S 0 99 Sat Sets new Saturation value for the selected color S 0 99 Lum Sets new Luminance value for the selected color S 0 99 Color corection page 2 CC View Views color area S On Off ViewInsert CC View insertion point S Main Mon Smoothing Selexts transition between corrected and unco...

Страница 47: ...ctions Function Level Possible values Exposure time page 1 Exp Sel Selects exposure time S Nom CRT 50 60 1 100 1 2000 Var Lighting Switches Lighting adj on or off S On Off Var Exp Sets variable exposure time S xx Hz or xx mSec Lighting Sets lighting adjustment value S 10 10 Exposure time page 1 VIPER Shutter Selects shutter preset Viper only S 90 180 216 VAR MAX etc Angle Sets variable shutter ang...

Страница 48: ... Select electronic soft focus filter B On Off SET Go to Set Soft Focus page B Filters page 3 LDK 500 only Monotone Select electronic monotone filter B On Off SET Go to set monotone filter page B Menu Selections Function Level Possible values Gradient filter page 1 LDK 500 only Gradient Turns gradient filter on or off B On Off Preset Selects gradient filter presets B ND0 3 0 6 0 9 Sunset BlueSky Va...

Страница 49: ...ocus filter page 3 LDK 500 only X pos Set X position of centre spot B 0 93 Y pos Set Y position of centre spot B 0 99 Reverse Reverse filter B On Off Asp Ratio Change aspect ratio of centre spot B 24 99 Menu Selections Function Level Possible values Monotone filter page 1 LDK 500 only Monotone Select electronic monotone filter B On Off Preset Select gradient presets B ND0 3 0 6 0 9 Sunset BlueSky ...

Страница 50: ...Dtl Diagonal Detail Function B Course Fine Detail page 5 Flw Gain Detail follows Gain B On Off Flw Zoom Detail follows Zoom B On Off Texture Enables Disables Texture B Enabled Disabled Dtl Func Turns Detail function on or off S On Off Menu Selections Function Level Possible values Detail Equalizer page 1 LDK 500 only Black Lvl Black level F 0 99 LowMid Lvl Low Mid level F 0 99 Mid Lvl Mid level F ...

Страница 51: ...ue in the menu Menu Selections Function Level Possible values SD detail page 1 SD DTL LVL Detail Level S SD 0 99 SD DTL Funct Detail Function S SD On SD Off SD LVL Dep Level Dependency B SD 0 99 SD NoiseSL NoiseSlicer B SD 0 99 SD detail page 2 SD V Detail Vertical detail level B SD 0 99 SD C Fine Detail fine adjustment B SD 0 99 SD detail page 3 SD SOFT LVL Soft detail level B SD 0 99 SD Soft DTL...

Страница 52: ...52 OCP 400 Operational Control Panel User s Guide v12 0 Chapter 4 Operation ...

Страница 53: ...Depth 354 x 82 x 85 mm 13 9 x 3 2 x 3 3 in without joystick Weight approx 2 5 kg 5 5 lbs Operating temperatures 0 to 45 C 32 to 113 F Storage temperatures 25 to 70 C 13 to 158 F Power requirements 12 VDC nom Power consumption 8 5 W max Ethernet connection RJ 45 connector 10Base T 100Base TX compliant with IEEE 802 3 Serial connections Sub D connector RS 232 or RS 422 protocol ...

Страница 54: ...ional Control Panel User s Guide v12 0 Chapter 5 Specifications 5 2 Dimensions Figure 5 1 Dimensions SKIN SKIN GAMMA GAMMA FLARE FLARE GAIN BLACK EXTENDER 354 82 338 41 325 207 25 3 40 5 83 58 8 141 8 6 5 14 5 6 5 14 5 ...

Страница 55: ...rol panels can be looped through An optional loop through power cable art nr 8926 591 00501 is available at Grass Valley Pin Description 1 GND 2 no connection 3 no connection 4 12 VDC input nominal It is recommended to use Grass Valley s LDK 5903 power supply unit to power the OCP XLR 4 pin male panel view 3 2 4 1 Pin Description 1 GND 2 no connection 3 no connection 4 12 VDC output This socket su...

Страница 56: ...smit data TX 3 Receive data RX 4 no connection 5 no connection 6 Receive data RX 7 no connection 8 no connection Ethernet 10Base T 100Base TX compliant with IEEE 802 3 edition 2000 8 pin standard RJ 45 ethernet connector Pin RS 232 RS 422 1 no connection no connection 2 RXD GO_A 3 TXD RET_B 4 nDTR reserved 5 DGND or 12 V DGND or 12 V 6 nDSR reserved 7 nRTS GO_B 8 nCTS RET_A 9 12 V or DGND 12 V or ...

Страница 57: ...tact 1B 3 Preview contact 1C 4 REF external 5 GND 6 not used 7 not used 8 Tally input 9 shield Sub D connector 9 pin male 1 2 3 4 5 6 7 8 9 Only used when an DMC camcorder is connected legacy feature 1 2 3 4 5 6 7 8 9 1A 1B 1C Preview switch Preview connector Preview switch not pressed 1A is connected to 1C Preview switch pressed 1A is connected to 1B ...

Страница 58: ...58 OCP 400 Operational Control Panel User s Guide v12 0 Chapter 6 Connectors ...

Страница 59: ...OCP 400 Operational Control Panel User s Guide v12 0 59 ...

Страница 60: ...Copyright Grass Valley Nederland B V ...

Отзывы: