Environment and Location
Rack-mounting Considerations
Rack-mounting Considerations
To prevent physical injury when mounting or servicing the LiveTouch (SQ2000) Server in a
rack, you must take special precautions to ensure that the system remains stable.
The following guidelines are provided for your safety:
•
Caution:
the LiveTouch (SQ2000) server is heavy (28.25Kg) and will need two people to
lift into the rack.
• A rack installation kit is supplied with the LiveTouch SQ2000 Server (as shown below).
• Mount units from the lower part of the rack if these are the only components in the
rack.
• Mount equipment so that uneven mechanical loading causing hazardous conditions
does not arise.
Blue Arrows:
Loosen these screws while installing the rack kit in a rack, to allow the telescopic effect to
work. Tighten them back once the rack kit is installed.
Green Arrows:
When installing the rack kit, only use the two middle rack mount screw holes as shown in
the diagram. The holes above and below are for the server. All four screw holes can be used
each side on the back.
Fig. 3-1: Rack Mount kit Installation.