Environment and Location

Rack-mounting Considerations

Rack-mounting Considerations

To prevent physical injury when mounting or servicing the LiveTouch (SQ2000) Server in a 
rack, you must take special precautions to ensure that the system remains stable.

The following guidelines are provided for your safety:

Caution:

 the LiveTouch (SQ2000) server is heavy (28.25Kg) and will need two people to 

lift into the rack.

• A rack installation kit is supplied with the LiveTouch SQ2000 Server (as shown below).

• Mount units from the lower part of the rack if these are the only components in the 

rack.

• Mount equipment so that uneven mechanical loading causing hazardous conditions 

does not arise.

Blue Arrows:

Loosen these screws while installing the rack kit in a rack, to allow the telescopic effect to 
work. Tighten them back once the rack kit is installed. 

Green Arrows:

When installing the rack kit, only use the two middle rack mount screw holes as shown in 
the diagram. The holes above and below are for the server. All four screw holes can be used 
each side on the back.

Fig. 3-1:  Rack Mount kit Installation.

Содержание LIVETOUCH SQ2000

Страница 1: ...Installation Manual 13 06520 010 2021 02 19 LIVETOUCH SQ2000 SPORT HIGHLIGHTS REPLAY SYSTEM ...

Страница 2: ... without notice Terms and Conditions Please read the following terms and conditions carefully By using LiveTouch documentation you agree to the following terms and conditions Grass Valley hereby grants permission and license to owners of LiveTouch to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or b...

Страница 3: ...r to making any other equipment connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components are present which may be damaged by electrostatic discharge Use anti static procedures equipment and surfaces during servicing Indicates that the equipment has more than o...

Страница 4: ...id connector damage Disconnect power before cleaning the equipment Do not use liquid or aerosol cleaners use only a damp cloth Dangerous voltages may exist at several points in this equipment To avoid injury do not touch exposed connections and components while power is on High leakage current may be present Earth connection of product is essential before connecting power Prior to servicing remove...

Страница 5: ...s Do not operate with suspected equipment failure If you suspect product damage or equipment failure have the equipment inspected by qualified service personnel To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel This unit may have more than one...

Страница 6: ...them If any fluid leaks out of a damaged glass cell be careful not to get the liquid crystal fluid in your mouth or skin If the liquid crystal touches your skin or clothes wash it off immediately using soap and water Never swallow the fluid The toxicity is extremely low but caution should be exercised at all times Mesures de sécurité et avis importants La présente section fournit des consignes de ...

Страница 7: ...que l appareil visé a été testé par Underwriters Laboratory UL et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux États Unis La marque C CSA US certifie que l appareil visé a été testé par l Association canadienne de normalisation CSA et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux ...

Страница 8: ...enroulements de câbles afin de ne pas endommager les connecteurs Coupez l alimentation avant de nettoyer l équipement Ne pas utiliser de nettoyants liquides ou en aérosol Utilisez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement Pour éviter toute blessure ne touchez pas aux connexions ou aux composants exposés lorsque l appareil est sous...

Страница 9: ... libre d électricité statique L appareil peut comporter plus d un cordon d alimentation Afin de prévenir les chocs électriques débrancher tous les cordons d alimentation avant toute opération d entretien Veillez à toujours prendre les mesures de protection antistatique appropriées quand vous manipulez l équipement Pour réduire le risque de choc électrique branchez chaque cordon d alimentation dans...

Страница 10: ... vision Prenez une pause de 10 minutes après 30 minutes d utilisation Si l écran LCD ou TFT est brisé manipulez les fragments de verre avec précaution au moment de vous en débarrasser veillez à ce que le cristal liquide n entre pas en contact avec la peau ou la bouche En cas de contact avec la peau ou les vêtements laver immédiatement à l eau savonneuse Ne jamais ingérer le liquide La toxicité est...

Страница 11: ...y from its holder using a blunt instrument for leverage such as a screwdriver if necessary In some cases the battery will need to be desoldered from the PCB 4 Dispose of the battery and equipment according to your local environmental laws and guidelines WARNING Be careful not to short circuit the battery by adhering to the appropriate safe handling practices Do not dispose of batteries in a fire a...

Страница 12: ...ion can cause irreversible and permanent damage of eyesight Please read the following guidelines carefully Make sure that a fiber is connected to the board s fiber outputs before power is applied If a fiber cable e g patchcord is already connected to an output make sure that the cable s other end is connected too before powering up the board Do not look in the end of a fiber to see if light is com...

Страница 13: ...t Emission requirements EN61000 3 2 2014 Class A Electromagnetic Compatibility Limits for harmonic current emissions EN61000 3 3 2013 Electromagnetic Compatibility Limits of voltage changes voltage fluctuations and flicker EN55035 2017 Electromagnetic Compatibility of Multimedia Equipment Immunity requirements FCC CFR 47 Part 15 Class A Federal Communications Commission Rules Part 15 Subpart B Cau...

Страница 14: ...all be made with high quality double screened coaxial cables such as Belden 8281 or BBC type PSF1 2M and Belden 1694A for 3Gbps D TYPE CONNECTORS D type connectors shall have metal shells making good RF contact with the cable screen Connectors having dimples which improve the contact between the plug and socket shells are recommended Note This equipment has been tested and found to comply with the...

Страница 15: ...orm without Sacrifice 3 Instant Integrated Editing 3 Summary of the LiveTouch SQ2000 Server Features 4 Overview of LiveTouch System Components 5 LiveTouch Server 5 LiveTouch Panel 5 LiveTouch Desktop Client PC 5 LiveTouch ISA 5 LiveTouch Manager VM 6 LiveTouch Search VM Web Bin 6 2 Connecting the LiveTouch Components 7 Overview 7 LiveTouch SQ2000 Server Connectors 8 Removing the SQ2000 Server fron...

Страница 16: ...ouch SQ2000 Server Interface Cards 20 Supported Video Compression Formats 22 Supported Proxy Compression Formats 22 Supported Audio Formats 22 Environmental Specifications 23 Power Specifications 23 Reference Signal Specifications 24 Storage Option Specifications 24 Providing Information to Grass Valley 25 Basic Information 25 Software Application 25 Your Contact Details 25 Customer Support 25 Con...

Страница 17: ...s installation manual help you through the physical installation of your LiveTouch SQ2000 Server and advise you of all relevant safety aspects Fig 1 1 Example of LiveTouch SQ2000 Server and Replay System Components LiveTouch SQ2000 Server ...

Страница 18: ...nt The most internal storage available on any replay server in the market today Instant integrated craft editing available at every operator workstation using Frame Magic technology Instantly load any replay clip or playlist into a fully featured craft edit timeline Unique powerful flexible processing in mixed format workflows Dynamically mix UHD 3G and HD content on the same playout port LiveTouc...

Страница 19: ...00 can also seamlessly handle mixed SDR and HDR inputs Many sports productions require multiple deliverables is different resolutions and color spaces LiveTouch 2000 is the perfect replay solution in a mixed environment allowing ultimate flexibility Instant Integrated Editing LiveTouch is the only replay solution on the market to allow instant media sharing between replay and editing Using Grass V...

Страница 20: ...HDR S Log HLG PQ Redundancy Dual redundant PSUs Audio Embedded Audio External Audio MADI UHD Features Channels per server 8x 12G Inputs 4x 12G Outputs 4x 3G Overlay Outputs Storage Internal Storage Up to 64TB Browse Proxy H 264 and 720p browse workflows for editing and remote access Agile Codec Support Resolution Independent Inputs and Outputs 1080i 720p 1080p UHD Dynamic upscaling on output Set o...

Страница 21: ...st third party web applications such as RT Software tOG Sports for enhanced live sports workflows LiveTouch Desktop Client PC The LiveTouch Panel is paired to a LiveTouch Desktop Client PC which is offered as turnkey hardware or as a software only option The LiveTouch Client software runs on Windows 7 or Windows 10 as required The LiveTouch Desktop PC acts as the intermediary between the LiveTouch...

Страница 22: ...uch Server through the LiveTouch Manager enabling users to access recordings playout ports clips and playlists LiveTouch Search VM Web Bin The LiveTouch Search engine which provides the Web Bin functionality is also installed as a VM on the ISA Manager The LiveTouch Web Bin allows operators to search access and share clips and playlists across the system ...

Страница 23: ...uch system comprises the following components LiveTouch Panel LiveTouch Desktop Client PC LiveTouch Server SQ2000 Series LiveTouch ISA Managers Optionally Redundant Pair The rear panel connectors for the LiveTouch SQ2000 Server is described in the following sections ...

Страница 24: ...Components 1 Debug 2 I O Cards 3 12G 3G HD SDI 5 MADI 4 QSFP28 6 PSU 1 6 PSU 2 8 LTC In 9 USB 10 Control Network Interfaces 7 REF and Loop Through 11 CPU Tray 1 Debug 4 QSFP28 3 12G 3G HD SDI 5 MADI 1 Debug Item Description LiveTouch SQ2000 Server Connections 1 Debug connectors 2 I O Cards 3 0 to 11 12G 3G HD SDI connectors 4 IP A and IP B QSFP28 connectors 5 MADI In Out 6 PSU 1 and PSU 2 7 REF an...

Страница 25: ...d carefully pull the door away from the server body Do not move the door up and down as you pull away from the server body as on the right hand side there is an internal connector that connects the power switch and the USB connectors to an internal interface board Power Switch and USB connector and interface board Power Switch and USB Connectors Captive Screws ...

Страница 26: ...2000 Server as follows 1 Connect the server side of the Clipnet network cable to the Clipnet network adapter 2 Connect the other end of the Clipnet network cable to the network Gb Switch The Clipnet network cable is as follows Fig 2 2 LiveTouch SQ2000 Server Connections Clipnet Connectors Video Reference Input Video I O Video I O ...

Страница 27: ...he LTC connector and the house timecode The LTC input allows a timecode signal to be read by the LiveTouch Server and used as the system timecode as an alternative to the system reference VITC 8 An LTC cable of 1 meter in length is supplied Option Description Details Dual Ten Gigabit Copper Copper interface with RJ45 connections 10G BASE T Network carrier 10G BASE T Connector type RJ45 Cable type ...

Страница 28: ...ting the LiveTouch Server 9 Connect the power cables between the PSU sockets and the power sources mounted in the rack as described in Chapter 4 Power Supplies Note It is recommended to lock the LTC to the same house reference signal as the Server ...

Страница 29: ...n the desktop environment Attention should be paid to the cooling information for the LiveTouch server The ambient temperature for all the supplied equipment should not exceed the limits of 5 and 30 C 41 to 86 F at a relative humidity of 10 to 90 non condensing Installing the equipment in a clean environment with moderate temperature and humidity will promote a long and trouble free equipment life...

Страница 30: ...ed with the LiveTouch SQ2000 Server as shown below Mount units from the lower part of the rack if these are the only components in the rack Mount equipment so that uneven mechanical loading causing hazardous conditions does not arise Blue Arrows Loosen these screws while installing the rack kit in a rack to allow the telescopic effect to work Tighten them back once the rack kit is installed Green ...

Страница 31: ...th sides and the cooling fan exhausts at the rear of the units must not be obstructed a minimum clearance of 200 mm 8 inches at the rear of the rack is essential 2 Air intakes situated at the front and on both sides are to allow the inflow of cooling air and must not be obstructed Airflow through the SQ2000 server is displayed by the red arrows in the diagram above Diagram showing air flow through...

Страница 32: ...16 Environment and Location Component Cooling ...

Страница 33: ...be serviced by trained personnel Before powering on the LiveTouch Server make sure that all foam used to protect the device in transit is removed The power supplies for the LiveTouch SQ2000 Server are locate at the rear of the unit The power supplies do not have independent on off switches The LiveTouch server has an On Off switch on the front panel Note To reduce the risk of electric shock plug e...

Страница 34: ... The power supply units PSUs in the LiveTouch SQ2000 Server are both hot swappable so can be individually removed from the unit Unplug the PSU from the mains and then remove by pressing the release clip hold the handle and carefully withdrawing the PSU from the body of the Server Note The Power Supplies have NO user serviceable parts inside and if one should become faulty it should be replaced imm...

Страница 35: ...19 Specifications Overview This section defines the specifications of the LiveTouch SQ2000 Server LiveTouch SQ2000 Server Specifications Fig 5 1 SQ2000 Dimensions ...

Страница 36: ...ming to SMPTE 299 ANSI SMPTE 272M Formatting AES EBU Audio into Digital Video Ancillary Data Space 48KHz synchronous SMPTE 292M Bit Serial Digital Interface for High Definition Television Systems SMPTE 424M 3Gb s Signal Data Serial Interface SMPTE 299M 24 Bit Digital Audio Format for HDTV Bit Serial Interface Outputs Connector type HD BNC x 1 per port 1 5 GHz 3 GHz 12 GHz Input Impedance 75 ohm Ma...

Страница 37: ...type RJ45 Cable type CAT 6A Maximum expected operating distance 100 m if patch panels are used this will reduce Communication protocols TCP IP UDP IP Dual Ten Gigabit Optical Optical interface with SFP LC connections 10G BASE SR Network carrier 10G BASE SR Connector type LC Cable type 50 125 μm or 62 5 125 μm Fibre Maximum expected operating distance Up to 300 m dependent on type Communication pro...

Страница 38: ...nuous clips at starts and stops V Notch fades to and from silence Freely intermix different audio formats on playback Audio input patching Audio output patching Standard Details Description HD 1080i 59 94 1080i 50 720p 59 94 720p 50 AVC Intra DNxHD XAVCi 1080p Level A 1080p 59 94 1080p 50 AVC Intra DNxHD XAVCi UHD 2160p 59 94 2160p 50 XAVCi Standard Details Compression HD 720p 59 94 720p 50 H264 a...

Страница 39: ...ions Mains Rating Dual Source 90 264 V The equipment is designed to operate with a mains supply tolerance of 6 and 10 of the rated values Mains Input Frequency 50 60 Hz Inrush Current peak 60 A Max for 115 V AC per module 30 A Max for 230 V AC per module Input Connector IEC320 C14 Efficiency Typical 85 at 115 V AC 80 at 240 V AC Earth Leakage Current Less than 1 5 mA both Isolation Device The sock...

Страница 40: ...other equipment and must be terminated to 75 ohm The 525 59 94 or 625 50 signal can be a Black Burst video signal 300 mV sync with VITC vertical interval timecode Reference TImecode The platform extracts VITC vertical interval timecode from this external locking reference to provide the system with a studio time reference The default lines from which VITC are extracted are PAL Lines 19 and 21 and ...

Страница 41: ...references etc and where they are being generated Outputs Provide full details of the Output Signals required and how they are being monitored System Provide a brief description of the system in which your equipment is currently being used Your Contact Details In addition to the above remember to provide us with your contact details to enable us to get in touch with you swiftly Name s Telephone E ...

Страница 42: ...26 Product Support Customer Support ...

Страница 43: ...n a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An on line form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Отзывы: