PTP - An Overview
PTP provides a mechanism for distributing a common reference clock throughout the system.
Each device maintains an internal clock that is synchronized to this common reference clock.
RTP timestamps within the RTP packet header (and extended header) are used for
synchronization.
Synchronization across multiple essence streams is achieved by comparing the offset between
the RTP timestamp and clock.
Setting Spigot Configuration
To set a new spigot configuration, follow these steps:
1 From the
Configuration
page, select the required software from the
Software Version
pane, then select the firmware which provides the required combination of inputs, outputs
and flow standards from the list displayed on the
Card Firmware
>
New
pane.
Note that
Restore
and
Restart
buttons are displayed only when an item not currently
installed is selected.
2 Enable the
Reset to Defaults on Restart
checkbox. This will cause existing details stored
on the module, other than network IP settings, to be cleared down prior to restarting the
module. See
on page 92 for more information.
3 Click
Restart
to restart the module and implement any changes made.
GUID
Displays the absolute unique identifier associated with the
module.
Domain
R uses domains to partition a network; only nodes on
the same domain can communicate with one another. A
domain is uniquely identified with a number and a friendly
name/alias.
Set an ID as required, then press
Take
to confirm the change.
Interface Configuration
Displays
the IP address for each Ethernet interface.
Card Firmware/Software
Version
Each software version contains multiple firmware images.
These allow different spigot input/output and flow standard
combinations to be selected. See
, below, for more information.
Reset to Defaults on Restart
Enable checkbox to cause any existing details stored on the
module, other than network IP settings, to be cleared down
prior to restarting the module. See
, below, and
on page 92 for more
information.
IMPORTANT!
Existing details must be cleared down before establishing a new
configuration
. Failure to do this may result in unexpected behavior
from the module.
Option
Operation
Содержание IQMIX25 Series
Страница 14: ...xiv Notices...
Страница 17: ...xvii IQMIX25 40 User Manual Ethernet Arcnet 93 Interop Page 94 SFP Configuration Page 96 Contact Us 97...
Страница 18: ...xviii Table of Contents...
Страница 22: ...22 Introduction Rear Panel View IQMIX4011 3B3 IQMIX2500 2B3 IQMIX2501 3B3...
Страница 26: ...26 Introduction Enclosures...
Страница 30: ...30 Connections SFP Link LED Indicators...
Страница 32: ...32 Card Edge LEDs...
Страница 98: ...98...