21
2
Technical Specification
Inputs, Outputs and Controls
Inputs/Outputs
RollCall Remote Control
BNC connector
RollCall/SNMP over TCP/IP
10/100 baseT Ethernet
Video Reference
BNC connector x 2
PSU Status
Molex connector x2 (Molex Header
part number: 22-27-2031)
Preset Controls
Additional Controls via RollCall Remote Control System
Full Control via web browser-based Java RollCall control panel (available from chassis), any hardware RollCall control
surface or standard RollCall Control Panel PC Application.
Specifications
Modules
Module Complement
20 slots wide. Cards can be 1, 2, 3 or more wide
Module Card Dimensions
100 mm wide, 340 mm long
Module Rear Panel Dimensions
129 mm high (-A versions and -B versions), 40.4 mm (double width), 20 mm
(single width) wide
Power
Input Voltage Range
100-240 V 50/60 Hz
Input Connector
IEC320 C14
Power Consumption
1000 VA maximum
Modules Power Dissipation
IQH4B - 700 LU maximum
Power is quoted in Load Units (LU) and is taken from the positive rail only
Output
+12 V and -7.5 V ± 5%
Note that all modules have built-in power supply fuses
CE Performance Information
Environment
Commercial and light industrial E2 immunity, controlled EMC E4 emissions
Peak Mains Inrush Current following a
5 second mains interruption
35A @ 230VAC
Reference
Analog Reference
2 x Analog Reference inputs
Black (HD tri-level and SD bi-level) and Black Burst (SD bi-level)
SD bi-level – RS170A
HD tri-level – SMPTE 240M, 274M and 296M
Connector/Format
BNC/75 Ohm panel jack on standard IQ connector panel
Analog Reference Return Loss
SD bi-level > 40 dB to 5.5 MHz
HD tri-level > 30 dB to 30 MHz