Restart Thomson FlashNet MDI. This re-synchronizes the
Aurora Browse database with the FlashNet archive
fi
le system.
Workaround:
The problem occurs when you modify (add/delete) the
FlashNet archive
fi
le system using some tool other than Aurora
Browse. For example, if you label the FlashNet
group/volume(s) using dtool.exe (supplied by SGL) or
archive/delete an asset using testapi.exe or any other SGL
supplied tool, you cause the problem. Since Aurora Browse
does not support bi-directional synchronization with FlashNet
archive, the Aurora Browse database goes out of sync with
FlashNet.
NTFS MDI cannot detect if a remote machine is online. This
occurs if NetBIOS has been disabled.
Description:
CR75426
On machines monitored by the NTFS MDI, such as the Proxy
NAS or the MediaFrame server, NetBIOS is enabled by default
Workaround:
at the factory. Do not change this con
fi
guration. The NTFS
MDI uses port 139, which becomes unavailable when NetBIOS
is disabled
GXF import (from within Aurora Edit) into a scavenge bin
fails.
Description:
CR58258
Import
fi
le into non-scavenge folder. When the import is
complete, move the clip to the scavenge folder.
Workaround:
If one Aurora Browse user attempts to delete an asset at the
same time another Aurora Browse user is viewing the clip,
Description:
CR57788
the High-resolution material will be deleted, however the proxy
will remain.
After the other user is no longer viewing the clip, retry deletion
of the asset.
Workaround:
On certain systems, occasional delayed write popup windows
occur during Smart Bin Ingests. Both High-resolution Aurora
Description:
CR59288
Edit material and proxy are successfully created, however the
popup dialog windows remain on the Smart Bin Encoder
computer.
Periodically, the Smart Bin Encoder should be monitored and
these windows closed.
Workaround:
Aurora Browse will not scavenge audio-only assets.
Description:
CR58568
No workaround available.
Workaround:
If you transfer a single asset to an archive that already has an
asset of that name, a dialog box appears asking if you want to
Description:
CR92283
rename the asset. If you transfer a batch of archives without
enabling auto-rename, no dialog box prompts you to rename
the assets; instead Browse returns an error message.
Specify auto-rename before archiving the batch of assets.
Workaround:
40
Aurora Browse Version 7.1.0 Release Notes and Upgrade Instructions
18October 2010
Known Issues