11
Power Up
Power Up
The front LED indicators and configuration switches are illustrated in
. Upon power-up, the green PWR LED should light and the yellow
CONF LED should illuminate for the duration of module initialization.
Operation Indicator LEDs
With factory default configuration and a valid input signal connected, the
green PWR LED and one of the green signal standard LEDs (525 or 625)
should illuminate (refer to
to see the possible operating
indicator combinations).
Video input presence is indicated by the 525 or 625 LED (indicating a
525-line or 625-line input signal has been detected). Line standard must be
set manually, there is no auto detection.
Figure 4. LEDs and Configuration Switches
16-position
Rotary switch
Momentary toggle switch
525 – Green LED on indicates 525-line input and reference are present
PWR – Green LED on indicates power OK
FAULT – Red LED is off during normal operation
Ejector Tab
AUTO – Disabled
625 – Green LED on indicates 625-line input and reference are present
Module Configuration Switches and LED
2ND LED
0543_06r1
0
1
2
3 4
5 6 7
8
9
A
B
CD
E
F
COMM – Yellow LED on indicates communication bus traffic
CONF – Yellow LED on indicates module is initiating, changing operating
mode, or updating firmware
Содержание 8960DEC -
Страница 4: ...4 8960DEC Instruction Manual Preface ...
Страница 6: ...6 8960DEC Instruction Manual Contents ...
Страница 26: ...26 8960DEC Instruction Manual Configuration Figure 10 Levels Display ...
Страница 38: ...38 8960DEC Instruction Manual Functional Description ...
Страница 42: ...42 8960DEC Instruction Manual Index ...