Remote Configuration
Settings Web Page
The Settings web page for 8949MDA-CFR (
Figure 12 on page 24
) and
8949MDA-SFR (
Figure 13 on page 24
) provides a reporting of signal control for
DA output. This page gives the model, the description and the frame location. The
input configuration is made on this web page.
The parameters concerning the configuration of a 8949MDA module are explained
below:
The
Routing Mode
area will be different, depending on the presence and the type
of fiber optic submodules. This area shows the selected inputs and the outputs.
•
Coax In 1
– Selection of J9 input.
•
Optic 1 or/and 2
– Selection of the optical input.
•
Optic Outputs
–
Not Applicable
in the case of the Dual Receiver
(1310NM-DRL) fiber optic submodule type. In the other cases choose between
Enable
or
Disable
the optical outputs.
•
Input Reporting
– Choose between
Enable
or
Disable
. The
Enable
parameter
raises alarms towards 8900NET module on the input signals (presence of
signal). The color of arrows on the Status page will be automatically changed.
The
Disable
parameter will change the color of arrows on the Status web page
to gray to show they are not being monitored or reported to upper level control
devices.
•
Input Format
– Selection of the input format transported on the HD-SDI or
SD-SDI signal. Refer to the
Table 2 on page 11
.
•
Carrier Detect
– Indicates the input signal presence on DA.
•
Locked Rate
– This value is linked to the input bitstream rate detected.
•
Video Format
– This value reports the input format detected.
•
Monitoring Format
– This value indicates the downscaled output format.
•
Composite Color Bar
– This parameter allows the selection of a composite color
bar pattern on the downscaled outputs.
•
Composite Setup
– This parameter is shown if the
Monitoring Format
is
480i/59.94 and allows to be set to
Setup
or
No Setup
as shown in
Figure 12 on
page 24
.
Use