TECHNICAL DATA
GENERAL SPECIFICATION
Model Name
Graphite 10
Model Number
GR910
Overall Height
735 mm
Overall Width
605 mm
Overall Depth
494 mm
Net Weight
151 kg
CPR DECLARATION OF PERFORMANCE
The materials, design, construction and
operating instructions, as well as the CE
marking, meet or exceed the EN13240
Type Test requirements for this type
of appliance. Data derived from Kiwa
GasTec BS EN13240: 2001 tests
BURNING WOOD LOGS
(intermittent use):
Nominal Heat Output
10.0 kW
Refuelling Interval
1.0 hr
Efficiency (net)
80.3%
Mean CO Emission (at 13%)
0.14%
Mean Flue Gas Temperature
348ºC
Flue Gas Mass Flow
5.7 gs
SMOKELESS FUEL –ANCIT
Intermittent use:
Nominal Heat Output
11.0 kW
Refuelling Interval
2.0 hrs
Efficiency (net)
71.9%
Mean CO Emission (at 13%)
0.26%
Mean Flue Gas Temperature
418ºC
Flue Gas Mass Flow
6.7gs
5
SMOKELESS FUEL –ANCIT
Continuous use:
Nominal Heat Output
11.7 kW
Refuelling Interval
4.0 hrs
Efficiency (net)
73.6%
Mean CO Emission (at 13%)
0.24%
Mean Flue Gas Temperature
404ºC
Flue Gas Mass Flow
7.6 gs
Tests at nominal output, burning both
wood logs and mineral fuel, were
carried out with a flue draught of 12 Pa.
MINIMUM DISTANCES TO
COMBUSTIBLE MATERIALS
Rear
600 mm
Sides
600 mm
FLUE
Flue configuration
top or rear
Flue pipe diameter
(6”) 150 mm
Height to centre of rear flue
560 mm
From centre of top flue to back
168 mm
Minimum flue height
from top of stove
4500 mm (15’)
Recommended flue draught
12 Pa
FUEL REQUIREMENTS
Wood Logs:
Moisture content
<20%
Maximum Log Length
450 mm (18”)
Maximum Fuel Load
4.15kg (9 lb 2 oz)
Multi Fuel:
Authorised Smokeless Fuels
Recommended Fuel Load
2.78 kg (6lb 2 oz)
See
www.hetas.co.uk
for approved fuels