Graphite GR910 Скачать руководство пользователя страница 1

Graphite 10 Model GR910 

Free-standing Multi Fuel Non-Boiler Stove

Instruction Manual

-

-

Published August 2014

Please note

 This appliance must, at all 

times, be operated in accordance with 
the instructions to minimise the amount 
of smoke produced.

You will need to refer to the serial 
number of your stove should you 
ever need to make a claim under the 
Graphite Warranty

You will find the 

serial number, beginning with GR, on 
the CE plate at the rear of the stove 
as well as on the lid of the outer 
packaging. 
Write the date the stove was delivered 
to you below as this is likely to differ 
from the purchase date.

Ref: GR910 / UK-NI-ROI / V4-05-07-14

Graphite

www.hi-flame.com

Содержание GR910

Страница 1: ...oke produced You will need to refer to the serial number of your stove should you ever need to make a claim under the Graphite Warranty You will nd the serial number beginning with GR on the CE plate...

Страница 2: ...Tips Removing Ash Installation Check list Installation General Guidelines Commissioning Trouble shooting Routine Checks Standing Down Routine Maintenance Annual Service Service Record The Graphite Wa...

Страница 3: ...Air enters at the base of the stove is pre heated to ensure the re chamber is not cooled down by new colder air This ensures a higher re chamber temperature and therefore a cleaner more ef cient burn...

Страница 4: ...4 GENERAL DIMENSIONS All dimensions in millimetres...

Страница 5: ...net 71 9 Mean CO Emission at 13 0 26 Mean Flue Gas Temperature 418 C Flue Gas Mass Flow 6 7gs 5 SMOKELESS FUEL ANCIT Continuous use Nominal Heat Output 11 7 kW Refuelling Interval 4 0 hrs Ef ciency ne...

Страница 6: ...always be quickly referred to Never let anyone use the stove who is unfamiliar with its correct operation 6 WATCH OUT CARBON MONOXIDE KILLS PACKING LIST As soon as you receive your new stove please ch...

Страница 7: ...information please consult England Wales Building Regulations Document J revised October 2010 Combustion Appliances and Fuel Storage Systems www planningportal gov uk Scotland Building Standards 2001...

Страница 8: ...VICE Ensure that an approved carbon monoxide detector BS EN50291 2001 is tted in the same room as the stove It should be powered by a battery designed for the working life of the alarm Please note tha...

Страница 9: ...sure that it has not moved This is a heavy metal plate which sits at an angle The base of this plate should sit securely on top of the tertiary air channel on the back wall with retaining lips on the...

Страница 10: ...e re cement if necessary Re attach the lid ensuring it is pushed towards the back of the stove and locks securely against its locating lugs When the lid is properly located the ue collar should be per...

Страница 11: ...the bolts supplied This makes a discreet ush tting closure of the lid aperture and does not need sealing with re cement Re attach the lid ensuring it is pushed towards the back of the stove and locks...

Страница 12: ...otland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefor...

Страница 13: ...ecause of the high chemical adhesive 13 RECOMMENDED FUELS The Graphite 10 GR910 stove lets you burn wood in non Smoke Control Areas and only approved smokeless multi fuels not wood in Smoke Control Ar...

Страница 14: ...ing www hetas co uk and www solidfuel co uk PROHIBITED FUELS Never use your stove like an incinerator Burning prohibited fuels is an offence in a Smoke Control Area and could create nuisance smoke whi...

Страница 15: ...ich could cause ash or small lighted embers to be drawn from the rechamber and beyond the protective hearth Never operate the stove without the re fence or log guard in position The stove is not desig...

Страница 16: ...proximately 25 to 50mm 1 to 2 C Refuelling Logs These should be approximately 75 to 100mm thick 3 to 4 Bigger logs should be split down to this size Lighting a Wood Fire The main difference between sm...

Страница 17: ...anion tool and the main refuelling wood can be quickly set Wood burns best if the ames have other wood to play off For example a single dense piece of wood or log will not burn as well as 2 or 3 small...

Страница 18: ...f the log surface is predominately black and or the ames are a dull orange then there is still some time to go before the re is operating at full temperature Never leave the stove unattended after ref...

Страница 19: ...the rechamber door is opened Rake the embers and spread them out to make an even bed You may need to add some kindling to re establish the re Add the new wood as before ensuring that the logs are not...

Страница 20: ...making sure to leave plenty of air space Once the mineral fuel is burning well add more fuel until a there is a good bed of burn ing fuel Avoid stacking too much fuel against the back and sides of th...

Страница 21: ...ch day to burn off any potential soot and creosote build up but be careful not to over re the stove This is particularly important if you regularly burn low for long periods such as overnight burning...

Страница 22: ...ur container All of this becomes second nature once you have used your stove for a few days REMOVING ASH Wood will produce a lot less ash than multi fuels and it would not be unrealistic to expect to...

Страница 23: ...l requirement to ensure that your stove installation complies with all applicable building regulations it is also a requirement of your Warranty that the stove is installed by a competent person such...

Страница 24: ...England and Wales there is a minimum requirement for the hearth The replace recess or opening is suitably constructed and conforms to all applicable building regulations and can accommodate the stove...

Страница 25: ...replace side and rear walls should be at least 75mm thick and made of non combustible brick or stone In a replace setting you should allow a minimum distance of 25 100mm 4 from the back of the stove a...

Страница 26: ...control over the fuel burn rate and improved environmental and fuel ef ciency Your existing chimney could leak Association of Chimney Sweeps at www chimneyworks co uk or the Guild of Master Chimney S...

Страница 27: ...mortar to make a complete seal on each joint Even though not particularly old this could still potentially cause leaking smoke and fumes or condensation stains Your approved installer will be able to...

Страница 28: ...thoroughly inspected by an approved installer or chimney sweep and any necessary repairs have been carried out Causes Inadequate cleaning Chimney res occur when soot and creosote have built up to suc...

Страница 29: ...as these produce excessive soot and creosote See page 13 29 STOVE FLUE OR OTHER COMPONENTS GLOWING RED Prevention The Primary and Secondary air controls should be immediately closed to let the re die...

Страница 30: ...ht This limits the effectiveness situation you should take immediate avoiding action Prevention Open doors and windows to ventilate the room and let the re go out to allow the stove to cool Never pour...

Страница 31: ...h case a complete new rope seal should be tted See the section on tting a rope seal page 35 31 STOVE NOT PROVIDING ENOUGH HEAT This problem is also usually indicated by dull orange lifeless ames and w...

Страница 32: ...llowed to build up A proprietary stove glass spray or gel is strongly recommended see page 34 Causes Air Controls Ensure that you fully understand how the Airwash system works and that you have determ...

Страница 33: ...N There will be some point in the year when you will not need to use your stove for a considerable time and taking care to clean it thoroughly then will save you much time later This is also a good ti...

Страница 34: ...note that minor cracks are perfectly normal due to the high temperatures created inside the stove If necessary small cracks can be repaired using a proprietary heat resistant re cement your stove dea...

Страница 35: ...you can use traditional stove black polish which your Graphite dealer can supply Make sure the stove is cold and use protective gloves as this type of polish can cause deep staining to the skin and n...

Страница 36: ...the stove glass on both sides Door Seal Check that this continues to make an air tight seal and replace if necessary Ensure that the new rope joint is also in the middle at the base of the rope seal c...

Страница 37: ...e Signed Print Dealer s Stamp or HETAS Registration Number Date Next Service Due Signed Print Dealer s Stamp or HETAS Registration Number Date Next Service Due Signed Print Dealer s Stamp or HETAS Reg...

Страница 38: ...or holiday accommodation public bar where the stove s operation could be subject to abuse Graphite guarantee that your product will be free from defective parts materials and workmanship at the time o...

Страница 39: ...NAME CONTACT DETAILS and date of installation CHIMNEY SWEEP CONTACT DETAILS and date s chimney swept NOTES eg ue liner details etc INSTALLATION NOTES You may need to refer to these at some time in th...

Страница 40: ...te Properly installed operated and maintained this stove will not emit fumes into the dwelling Occasional fumes from removing ash and refuelling may occur However persistent fume emission is potential...

Страница 41: ...leave the premises Let the re go out Check for ue or chimney blockage and clean if required Do not attempt to relight the re until the cause of the fume emission has been identi ed and corrected If n...

Отзывы: