11
ASSEMBLY/SETTINGS
INFORMATION
EQUIPMENT AND ACCESSORIES
Transport case
- 1 pce
1.
Hex key
- 1 pce
2.
PREPARATION FOR OPERATION
BLADE INSTALLATION
Disconnect the power tool from power supply.
Installation and removal of the blade is toolless.
Turn the ring of the blade holder (
●
2
) and slide the blade into the holder until it stops (
fig. A
).
Release the ring of the blade holder (
●
2
) (the ring will return to the default position).
Pull the blade lightly to make sure it is properly fixed.
●
If the ring of the blade holder does not return to the default position, turn the ring manually.
FOOTPLATE ADJUSTMENT
Disconnect the power tool from power supply.
●
Loosen the footplate fixing screws (
6
).
Set the footplate (
●
7
) to appropriate distance (
fig. B
).
Tighten the footplate fixing screws (
●
6
).
OPERATION / SETTINGS
SWITCHING ON / SWITCHING OFF
The mains voltage must match the voltage on the saw rating plate.
Switching on
– press the switch button (
5
).
Switching off
– release pressure on the switch button (
5
).
Locking the switch (continuous operation)
Switching on:
Press the switch button (
●
5
) and hold in this position.
Press the switch lock button (
●
4
).
Release pressure on the switch button (
●
5
).
Switching off:
Press and release the switch button (
●
5
).
Work speed is controlled within its range with pressure on the switch button (
5
).
CUTTING
●
Put front part of the footplate (
7
) flat on the material that you plan to cut.
Adjust working speed to properties of processed material.
●
Switch on the saw and wait until it reaches full rotational speed at current setting.
●
Move the saw slowly and guide the blade along previously set cutting line (
●
fig. C
).
Cut at a steady rate, be careful not to overload the saw. Excessive pressure applied on the blade will suppress
operation and will affect cutting efficiency unfavourably.
During operation whole surface of the footplate should contact surface of the processed material.
OPERATION AND MAINTENANCE
Unplug the power cord from the mains socket before commencing any activities related to
installation, adjustment, repair or maintenance.