PHOTOVOLTAIC MODULES SAFETY 

AND INSTALLATION MANUAL Rev. M 

VALID IN NORTH AMERICA ONLY 

Valid from February 2011 

1305 South Bertelsen Road, Eugene, Oregon 97402, USA 

www.grapesolar.com 

Tel: 1-877-264-1014 (toll free), 1-541-349-9000, Fax: 1-541-343-9000 

 

 

 

10 

receive the incident sunlight perpendicularly to the module surface. 

5.4

 

For roof mounted systems, at least a 4 inch clearance is required between the module back 
surface and roof for rear ventilation and module cooling. 

5.5

 

Clearance of 1/12 inch (2mm) or more between modules is required to allow for thermal 
expansion of the frames. 

5.6

 

Keep the back surface of the module free from any foreign objects or structural elements which 
could come into contact with the module, especially when the module is under mechanical load. 

5.7

 

To prevent water from entering the junction box, which could result in a safety hazard, modules 
should 

not

 be mounted with the front/top glass facing downward. 

5.8

 

At least a 4 inch clearance between the module frames and structure, or wall, or ground is 
required to prevent wiring damage and allows air to circulate behind the module. 

5.9

 

PV modules can be mounted to the structure by the following methods:   

5.9.1

 

Mounting Holes: Secure the module to the structure using the mounting holes. There are 4 
mounting holes on module frame which have been evaluated by UL for mounting. Attach 
¼ -20 x 0.75” stainless steel screw via each mounting hole with ¼” stainless steel flat 
washer, and secure from behind with another stainless steel flat washer, local washer and 
nut. Torque the bolts to 6.3ft lbs (8.5Nm).   

5.9.2

 

Pressure Clamps or Clips: Mount the module with the clamps or clips on the module frame. 
Installers should ensure the clamps are of sufficient strength to allow for the maximum 
design pressure of the module. 

5.10

 

It is recommended that modules be securely fastened on the long side of the frames, but 
mounting the module only on the short side is allowed. The maximum mechanical load applied 
on the module 

must

 

not

 exceed 30 lbs/ft

(1600 Pascal). 

 

Содержание GS-S-150-SF

Страница 1: ...ocument applies to Grape Solar photovoltaic modules with model number GS S 150 SF GS S 155 SF GS S 160 SF GS S 165 SF GS S 170 SF GS S 175 SF GS S 180 SF GS S 185 SF Carefully read through this manual...

Страница 2: ...ebruary 2011 1305 South Bertelsen Road Eugene Oregon 97402 USA www grapesolar com Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 2 Table of Contents I General Information 3 II Safety P...

Страница 3: ...oor land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F cel...

Страница 4: ...connected modules have to be stored outside for any length of time always have the glass surface facing down and cover modules with water proof material to prevent water collecting inside the panel a...

Страница 5: ...id accidental exposure to live circuits 3 4 When working with modules exposed to light follow all applicable regulations regarding working with live electrical equipment 3 5 Do not install or handle t...

Страница 6: ...th or material before making or breaking electrical connections 3 15 Broken junction boxes or broken connectors are electrical and laceration hazardous and cannot be repaired Please contact the instal...

Страница 7: ...scal To avoid exceeding the 30 lbs ft2 mechanical loading limit site specific loads such as wind and snow should be taken into account 1 5 The site should not have exposure to extremely corrosive chem...

Страница 8: ...nnectors such as MC 4 connectors which are approved for use at the maximum short circuit current of the module 3 7 Over current device e g fuse or circuit breaker whose rating is not greater than the...

Страница 9: ...asher and 2 5mm grounding wire A cupped washer is required between grounding wire and the nut with torque less than 4N m Grounding wire should be directly connected with the screw 4 4 The rack must al...

Страница 10: ...nt top glass facing downward 5 8 At least a 4 inch clearance between the module frames and structure or wall or ground is required to prevent wiring damage and allows air to circulate behind the modul...

Страница 11: ...on 4 Do not remove the dirt by scraping or rubbing away from the module front surface when dry as this may cause micro scratches on the glass and lead to module performance degrading 5 Water can be us...

Страница 12: ...damage injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any infringement of patents or other righ...

Страница 13: ...16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 Max System DC Voltage V 600 600 600 600 600 600 600 600 NOCT 50 2 50 2 50 2 50 2 50 2 50 2 50 2 50 2 Current coeff K 0 06 0 01 0 06 0 01 0 0...

Отзывы: