www.grapesolar.com

 

Tel.  1

-

877

-

264

-

1014 (toll free), 1

-

541

-

349

-

9000, Fax:  1

-

541

-

343

-

9000

 

3

 

 

 

 

Valid from June 2018

 

Step 4: 

Use the 5-foot red & black cable pair to  

 

connect your positive and negative battery termi-

nals to the “Battery Positive” (use red cable from 

the positive battery terminal) and “Battery Nega-

tive” (use black cable from the negative battery 

terminal) inputs of the charge controller (the cen-

ter set of terminals).

 

Step 3: 

Mount controller if desired (note that it must be in a NEMA-4 rated enclosure if it is outdoors). 

 

GS-100+KIT EXPANDABLE PHOTOVOLTAIC 

POWER GENERATION SYSTEM 

CONFIGURATION MANUAL Rev. 180601 

If your battery has sufficient charge (11.5 volts or more), 

you should now see the controller’s LCD display activate. 

This means the controller has power (controllers are pow-

ered by the battery, not the panels). 

Step 5: Cut the 15-foot MC4 cable in half using wire cutters, stripping back the bare ends around 1/4”. 

Label the positive lead with tape to avoid polarity mismatch. 

Step 6:

 Connect the positive MC4 output of the panel to the 10 amp inline fuse, as shown below:

 