www.grapesolar.com
Tel. 1
-
877
-
264
-
1014 (toll free), 1
-
541
-
349
-
9000, Fax: 1
-
541
-
343
-
9000
3
Valid from June 2018
Step 4:
Use the 5-foot red & black cable pair to
connect your positive and negative battery termi-
nals to the “Battery Positive” (use red cable from
the positive battery terminal) and “Battery Nega-
tive” (use black cable from the negative battery
terminal) inputs of the charge controller (the cen-
ter set of terminals).
Step 3:
Mount controller if desired (note that it must be in a NEMA-4 rated enclosure if it is outdoors).
GS-100+KIT EXPANDABLE PHOTOVOLTAIC
POWER GENERATION SYSTEM
CONFIGURATION MANUAL Rev. 180601
If your battery has sufficient charge (11.5 volts or more),
you should now see the controller’s LCD display activate.
This means the controller has power (controllers are pow-
ered by the battery, not the panels).
Step 5: Cut the 15-foot MC4 cable in half using wire cutters, stripping back the bare ends around 1/4”.
Label the positive lead with tape to avoid polarity mismatch.
Step 6:
Connect the positive MC4 output of the panel to the 10 amp inline fuse, as shown below: